Step 1: Determine Heat Load
It is important to determine the heat load of your application to ensure that the selected chiller is large enough for the actual application. There are several ways to determine heat load (in kW), and understanding the process helps to calculate an accurate heat load.

Step 2: Determine Coolant Type, Temperature and Flow Rate
Once the heat load is known, the next step is to determine the coolant, target temperature, and flow rate the chiller must provide to the process. This can be determined by the amount of heat the process delivers to the coolant and the type of coolant used. For example, water has different properties than oil.

Step 3: Determine the installation environment
What kind of environment should the chiller system be installed in? For example, indoor applications can experience high temperatures and dirty air, while outdoor installations can experience low and high ambient temperatures. This will affect the selection of the chiller and will require accessories such as air filters and tank heaters.

Step 4: Use the Chiller Performance Chart
Now use the available chiller performance charts to select a chiller model that meets or exceeds the required cooling capacity based on chilled water supply temperature and maximum expected ambient air temperature. Safety margins should be considered for available sizes to maximize the value of chiller selection.

Step 5: Check the Pump Performance Chart
Check with us on the pump’s performance chart to ensure that the pump can increase the pressure enough at the design flow rate to meet the application requirements. Some liquid cooling systems have small coolant flow paths or long distances, and the average pressure loss may be higher.

Step 6: Final Selection
Finally, consider the remaining application requirements, such as power characteristics, control selection, footprint, proxy list, colors, etc. for the selected chiller. Choosing a standard chiller increases reliability and makes servicing easier with universal spare parts and global support.

私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!

 


低温冷水機

ウォーターチラー

温度制御範囲:-150℃~+50

 

 


冷暖房システム

ダイナミック温度制御システム

温度制御範囲:-120°C~+350°C

 

 

 


バッテリー冷却システム

自動車用テスト・チラー

温度制御範囲:-40℃~+100

 

 

 


半導体テストチラー

半導体テストチラー

温度制御範囲:-85℃~+250

 

 

 


工業用冷凍庫

工業用冷蔵庫

温度制御範囲:-150℃~-10

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
無料見積もりプラン

ロード...

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー