How to Prolong the Service Life of Industrial Chillers?
Attention should be paid to the use of industrial chillers: first, liquid medium should be added to the bucket before use, and second, the working power should be determined according to the model of the machine. The power of the power supply should be greater than or equal to the total power of the instrument, and the power supply must have a good grounding wind. , After using the chiller, all switches are turned off, unplug the power plug, and dry the liquid in the bucket.
During the normal operation of industrial chillers, it is inevitable that dirt or other impurities will affect the cooling effect. Therefore, in order to prolong the service life of the main unit and achieve a better cooling effect, regular maintenance and maintenance work should be done to ensure the normal operation quality of the chiller and improve production efficiency. The specific operations are as follows:
1. Regularly check whether the voltage and current of the industrial chiller are stable, and whether the sound of the compressor is running normally. When the industrial chiller is working normally, the voltage is 380V, and the current is within the range of 11A-15A, which is normal.
2. Regularly check whether there is any leakage of the refrigerant in the industrial chiller. According to the temperature change (winter, summer), the pressure display of the industrial chiller is also different. When the industrial chiller is working normally, the high pressure display is generally 11-17kg, and the low pressure display The range of 3-5kg is normal.
3. Check whether the cooling water system of the industrial chiller is normal, whether the fan of the cooling water tower and the sprinkler shaft are running well, and whether the built-in water tank of the industrial chiller is replenishing water normally.
4. When the industrial chiller is used for six months, the system should be cleaned, and it should be cleaned once a year. The main cleaning parts include: cooling water tower, cooling water pipe and condenser to ensure better cooling effect. When the industrial chiller is not in use for a long time, the circuit switches such as the water pump, compressor and the main power supply of the cooling water tower should be turned off in time.
私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!
Temperature Control Range: -45°C ~ +250°C 7 Inch Color Touch Screen With 2pcs of LED Display Controller Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -25°C ~ +200°C 7 Inch Color Touch Screen With 2pcs of LED Display Controller Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -40°C ~ +200 °C Temperature Control Accuracy: ±0.5 °C 7-Inch,10 Inch color FTF Touch Screen Display Note: Both Air Coo...
Temperature Control Range: -10℃ ~ +150℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -25℃ ~ +200℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -25℃ ~ +300℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -45℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -45℃ ~ +300℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -60℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -60℃ ~ +300℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -70℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -80℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -90℃ ~ +250℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled Ar...
Temperature Control Range: -100℃ ~ +100℃ (optional: -150℃ ~ +350℃) Temperature Control Accuracy: ±0.5 °C Note: Both Air Cooled And Water Cooled A...
Temperature Control Range: -25°C ~ +200°C One Machine for Two Reactors Temperature Control Accuracy: ±0.5 °C 7-Inch,10 Inch color FTF Touch Screen...
Temperature Control Range: -40°C ~ +200°C One Machine for Two Reactors Temperature Control Accuracy: ±0.5 °C 7-Inch,10 Inch color FTF Touch Screen...
Temperature Control Range: -25°C ~ -5°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar)...
Temperature Control Range: -45°C ~ -10°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar...
Temperature Control Range: -18°C ~ +30°C Microcomputer Temperature Controller High Performance Circulating Pump Note: Both Air Cooled And Water C...
Temperature Control Range: +5°C ~ +35°C Microcomputer Temperature Controller High Performance Circulating Pump Note: Both Air Cooled And Water Co...
Temperature Control Range: -60°C ~ -10°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar...
Temperature Control Range: -80°C ~ -30°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar...
Temperature Control Range: -110°C ~ -50°C (optional: -150°C ~ -5°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipola...
Temperature Control Range: -150°C ~ -110°C Siemens PLC Controller, Danfoss Electronic Expansion Valve Semi-Closed (Bipolar) Piston Compressor, Sem...
Temperature Control Range: -25°C ~ +30°C (optional: -120°C ~ +35°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -45°C ~ +30°C (optional: -120°C ~ +35°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -60°C ~ -20°C (optional: -120°C ~ +30°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -80°C ~ -20°C (optional: -120°C ~ +30°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, C...
Temperature Control Range: -120°C ~ -70°C (optional: -120°C ~ +30°C) Siemens PLC Controller, Danfoss Electronic Expansion Valve Brand Compressor, ...
The temperature range of the equipment is -110 ℃ ~ -40 ℃, using environmentally friendly refrigerant, the cooling speed is fast. The products use b...
It is widely used in high and low temperature testing of semiconductor equipment. Cold and heat sources for high temperature and low temperature co...
Temperature Control Range: -115°C ~ +225°C Siemens PLC Controller Danfoss / Emerson Fittings Application: Laboratory, Research Institute, ...
自動車用テスト・チラー
温度制御範囲:-40℃~+100
商品を見る
半導体テストチラー
温度制御範囲:-85℃~+250
商品を見る
工業用冷蔵庫
温度制御範囲:-150℃~-10
商品を見る
著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com
または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。
WhatsAPP WeChat