How do Recirculating Chillers Work?

 

The low-temperature recirculating chiller is also called a low-temperature chiller, a low-temperature circulator, and can achieve a low-temperature -120 ℃ refrigeration function. This type of equipment is often used in single-fluid freezing experiments, and is not a type of equipment from general space refrigeration, cold storage, and refrigerators. So, what are the points to pay attention to when using a recirculating chiller? What are the correct use methods and steps? The following will give you a detailed introduction.

How Recirculating Chillers Work?

A recirculating chiller transfer pump drives a heat transfer medium (usually water or oil) from a tank with a built-in heater to a temperature-controlled device, where it returns to the tank. The controller adjusts the temperature of the thermal fluid according to the heat flow temperature measured by the temperature sensor or the internal temperature of the temperature control device, thereby adjusting the temperature of the temperature control device.

How to use the recirculating chiller and matters needing attention?

1. When using it for the first time, first use a multimeter to check whether the power plug connected to the device is normal, whether there is a short circuit with each other or a bad state. If there is no abnormality, it can be used normally;

2. After the power is turned on, add the corresponding circulating water as required, turn on the power switch and the circulating pump switch on the equipment, so that the circulating water starts to run;

3. Set the temperature range of the recirculating chiller, set the temperature range of high temperature and low temperature, and observe it well. If the temperature range is large, continue to adjust the temperature range;

4. The circulating water of the low-temperature recirculating chiller is generally distilled water or the circulating water of the manufacturer is better. Do not use inlet water, river water, etc., which will cause the circulation pipeline to block. If tap water is used, it is recommended to clean the pipeline every year. it is good;

5. Check the pipeline and refrigerant of the recirculating chiller every six months for leaks, whether there is leakage, etc., which can be judged according to the parameters displayed on the pressure gauge. If the data is far from the usual data, it can be compared;

6. The recirculating chiller system needs to formulate an annual cleaning plan, including: cooling pipes, condensing parts, cooling water towers, etc., to avoid system blockage and make the refrigeration system operate more appropriately;

7. If the recirculating chiller is not used for a long time, it is recommended to turn off the circuit switches such as the water pump, compressor and power supply of the equipment.

私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!

 


ウォーターチラー

温度制御範囲:-150℃~+50

 

商品を見る

 


ダイナミック温度制御システム

温度制御範囲:-120°C~+350°C

 

商品を見る

 


自動車用テスト・チラー

温度制御範囲:-40℃~+100

 

商品を見る

 


半導体テストチラー

温度制御範囲:-85℃~+250

 

商品を見る

 


工業用冷蔵庫

温度制御範囲:-150℃~-10

 

商品を見る

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
無料見積もりプラン

ロード...

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー