検索 すべて検索

Five Common Chillers Performance Introduction

分類業界ニュース 226

Five Common Chillers Performance Introduction

 

Commonly used chillers include screw chillers, piston chillers, centrifugal chillers, etc., each of which has its own advantages and disadvantages. If we want to choose a suitable chiller, we need to understand the advantages and disadvantages of the equipment. Today, the LNEYA chiller manufacturer will introduce the performance of five common chillers to you.

1. Screw chiller: simple structure, few moving parts, few wearing parts, and long service life. The compression ratio is high and the EER value is high. It is not sensitive to wet stroke, the price is higher than the piston type, the single machine capacity is smaller than the centrifugal type, the speed is lower than that of the centrifugal chiller, and the noise of the large-capacity equipment is higher than that of the centrifugal chiller.

2. Piston chiller: It has a wide range of applicable pressures and is highly repairable. The material is simple, the general metal data can be used, the processing is simple, and the cost is low. There are many spare parts and many vulnerable parts. It belongs to the reciprocating motion, the oscillation is larger, and the unit cooling capacity weight is larger.

3. Modular chiller: According to the change of cooling load, the number of modules can be adjusted at any time, so that the output cooling capacity and the air conditioning load can be optimally matched and energy consumption can be saved. Light weight, compact structure, saving construction area. The cost is high, the spare parts are many, the wearing parts are many, and the maintenance cost is high. Under the partial load of a single magnetic head, the scheduling function is poor, and the stepless scheduling cannot be realized.

4. Centrifugal chiller: high impeller speed, large air volume and large single machine capacity. The unit cooling capacity weight is small, the ER value is high, and it can be adjusted steplessly within 10%~100%. Single-stage compressors experience “surge” at low loads and remain stable at full load. When the working conditions are opposite to the planned working conditions, with the decrease of the evaporating temperature, the power drops faster, and the cooling capacity drops faster than that of the piston chiller.

5. Water source heat pump chiller: save electricity and restore heat when working in winter. The environmental impact is evident, with a brief occurrence of a water column phenomenon between the source side and the load side in the system. The one-time capital contribution and operating expenses are high.

私たちは、最高級のオンタイムデリバリーをお約束 温度制御機器プロンプトが表示さに裏打ちされ、慎重アフターサービス。 ご相談ください 詳細はこちら!

 


低温冷水機

ウォーターチラー

温度制御範囲:-150℃~+50

 

 


冷暖房システム

ダイナミック温度制御システム

温度制御範囲:-120°C~+350°C

 

 

 


バッテリー冷却システム

自動車用テスト・チラー

温度制御範囲:-40℃~+100

 

 

 


半導体テストチラー

半導体テストチラー

温度制御範囲:-85℃~+250

 

 

 


工業用冷凍庫

工業用冷蔵庫

温度制御範囲:-150℃~-10

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com