25 Ton Chiller
The 25 ton chiller has been widely used in various industries that are becoming more and more familiar. Its main function is to provide industrial chilled water to equipment and products. The water temperature requirement can be adjusted according to the user’s requirements, but its accuracy can be more accurately controlled at ±0.5°C. However, during the operation of the unit, some users may encounter the situation that the temperature cannot drop, let us analyze the reason together!
There are mainly the following reasons:
1. As far as our 25 ton chiller is concerned, all the machines have been 100% performance tested before leaving the factory to ensure the normal operation of the machine. If this problem occurs during the initial use, it may be that the 25 ton chiller is not matched correctly.
2. When the 25 ton chiller is used for the first time, another reason why the temperature does not drop is that there are some problems with the installation of the cooling tower, circulation pump and piping of the equipment, which need to be carefully checked according to the installation diagram;
3. If this happens to the 25 ton chiller that has been used for more than half a year or one year, it may be the following problems:
a. The heat exchanger of the 25 ton chiller is too dirty. It is recommended to clean the heat exchanger and clean it regularly during subsequent use;
b. The refrigeration system of the 25 ton chiller is leaking Freon. It is recommended to find out the leak point, repair the welding, and add refrigerant;
c. It may be that the working temperature of the 25 ton chiller is relatively extreme, too high or too low, causing the industrial chiller to fail to meet the requirements. In this case, only a larger industrial chiller can be selected to meet the working requirements.
4. It may be that the water source used has impurities, which have been accumulated for a long time and attached to the pipes between the various devices, resulting in a small water flow. Therefore, it is necessary to clean the pipelines between the various equipment.
In the process of using the 25 ton chiller, the customer needs to find professional maintenance personnel to repair and deal with it. For users with poor water sources, the user needs to perform the following professional treatment, and maintain the water-cooled chiller at regular intervals.
低温チラー(水冷式・空冷式)
温度制御範囲:-150℃~-5
当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。
温度範囲 | -25°C ~ -5°Cシリーズ | -45°C ~ -10°Cシリーズ | -60°C ~ -10°Cシリーズ | -80°C ~ -30°Cシリーズ | -110°C ~ -50°Cシリーズ |
冷却能力 | 最大360kW | 最大360kW | 最大360kW | 270kWまで | 180kWまで |
循環式チラー (水冷・空冷)
温度制御範囲:-120℃~+30
私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。
温度範囲 | -25°C ~ +30°Cシリーズ | -45°C ~ +30°Cシリーズ | -60°C ~ -20°Cシリーズ | -80°C ~ -20°Cシリーズ | -120°C ~ -70°Cシリーズ |
冷却能力 | 最大38kW | 最大12kW | 最大7.2kW | 最大7.2kW | 最大8.6kW |
室温チラー/小型チラー
温度制御範囲+5℃〜+50
チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。
温度範囲 | -18°C ~ +30°C | +5°C ~ +35°Cシリーズ |
冷却能力 | 0.9kWまで | 最大50kW |
直接冷却式冷凍機
温度制御範囲:-120℃~-10
熱交換面積が小さく、熱交換が大きい場所に適している。
温度範囲 | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
コンプレッサーパワー | 8HPまで | 最大8HP*2 | 45HP*3まで |
直接冷却式超低温チラー
温度制御範囲:-150℃~-110
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | -150°C〜-110°C |
冷却能力 | 最大11kW |
スクリュー冷凍機
低温スクリュー冷凍機と常温スクリュー冷凍機
お客様のビジネスにカスタマイズされたソリューションを提供します。
温度範囲 | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
冷却能力 | 最大1027kW(シングルコンプレッサー) | 最大2134kW(デュアルコンプレッサー) | 最大934kW(シングルコンプレッサー) | 最大1940kW(デュアルコンプレッサー) | 最大467kW(シングルコンプレッサー) | 最大497kW(シングルコンプレッサー) |