20 Ton Chiller – Chiller Manufacturer

分類業界ニュース 182

20 Ton Chiller – Chiller Manufacturer

 

20 ton chiller is a very important refrigeration equipment for an enterprise. Its operation stability has a non-negligible effect on production efficiency and product quality. Therefore, regular maintenance of the chiller is required to ensure the normal operation of the chiller. of.

So, how to maintain the 20 ton chiller?

1. Replace lubricating oil

After the 20 ton chiller group is used for a long time, the oil quality of the lubricating oil will deteriorate, and the impurities and moisture inside the oil will increase, so it is necessary to observe and check the oil quality regularly, and replace it in time if any problem is found.

In addition, I would like to remind everyone that the grade of lubricating oil to be replaced must comply with the technical data to avoid additional damage to the chiller due to incorrect use of lubricating oil.

2. Replace the dry filter

The dry filter is an important part to ensure the normal circulation of the refrigerant. Since water and refrigerant are incompatible with each other, if there is water in the system, it will greatly affect the operating efficiency of the unit.

Therefore, the filter element inside the drying filter must be replaced regularly to keep the inside of the system dry for a long time.

3. Calibration of the safety valve

Both the condenser and evaporator of the 20 ton chiller are pressure vessels. According to regulations, a safety valve should be installed on the high-pressure end of the unit, that is, the condenser body. Once the unit is in an abnormal working environment, the safety valve can automatically release the pressure. Prevent possible damage to the human body caused by high voltage. Therefore, in order to ensure the safety of the staff, the safety valve must be checked regularly.

4. Cleaning of condenser and evaporator

The cooling water of the water-cooled condenser is an open circulation loop, and tap water is generally used to circulate through the cooling tower. However, when the content of calcium salt and magnesium salt in the water is large, it is easy to decompose and deposit on the cooling water pipe to form scale, which affects heat transfer. Excessive scaling will also reduce the circulation section of cooling water, reduce the amount of water, and increase the condensation pressure.

Therefore, when the water quality of the cooling water used is poor, the cooling water pipe should be cleaned at least once a year to remove scale and other dirt in the pipe.

 

カスタマイズされたソリューション


 

低温チラー

低温チラー(水冷式・空冷式)

温度制御範囲:-150℃~-5

当社は、-150℃の温度制御範囲を持つ低温冷凍機の生産を専門としており、さまざまな業界の冷凍ニーズを満たすことができます。

温度範囲 -25°C ~ -5°Cシリーズ -45°C ~ -10°Cシリーズ -60°C ~ -10°Cシリーズ -80°C ~ -30°Cシリーズ -110°C ~ -50°Cシリーズ
冷却能力最大360kW最大360kW最大360kW270kWまで180kWまで

 


循環式冷凍機

循環式チラー (水冷・空冷)

温度制御範囲:-120℃~+30

私達の再循環のスリラーは低温冷凍の技術を採用し、温度は- 120℃と低く、さまざまな付属品はカスタマイズ可能です。

温度範囲 -25°C ~ +30°Cシリーズ -45°C ~ +30°Cシリーズ -60°C ~ -20°Cシリーズ -80°C ~ -20°Cシリーズ -120°C ~ -70°Cシリーズ
冷却能力最大38kW最大12kW最大7.2kW最大7.2kW最大8.6kW

 


ウォーターチラー

室温チラー/小型チラー

温度制御範囲+5℃〜+50

チラーは様々な産業や研究所で広く使用することができ、カスタマイズされた設計をサポートしています。

温度範囲 -18°C ~ +30°C +5°C ~ +35°Cシリーズ
冷却能力0.9kWまで最大50kW

 


直接冷却機

 

直接冷却式冷凍機

温度制御範囲:-120℃~-10

熱交換面積が小さく、熱交換が大きい場所に適している。

 

温度範囲 -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
コンプレッサーパワー8HPまで最大8HP*245HP*3まで

 


 

直接冷却式超低温チラー

温度制御範囲:-150℃~-110

お客様のビジネスにカスタマイズされたソリューションを提供します。

 

温度範囲 -150°C〜-110°C
冷却能力最大11kW

 


スクリュー冷凍機

 

スクリュー冷凍機

低温スクリュー冷凍機と常温スクリュー冷凍機

お客様のビジネスにカスタマイズされたソリューションを提供します。

 

 

温度範囲 +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
冷却能力最大1027kW(シングルコンプレッサー)最大2134kW(デュアルコンプレッサー)最大934kW(シングルコンプレッサー)最大1940kW(デュアルコンプレッサー)最大467kW(シングルコンプレッサー)最大497kW(シングルコンプレッサー)

 

著作権情報はlneya-online.comに帰属します。詳細はメールにてお問い合わせください: lilia@lneya.com

または、下記のWhatsAppまたはWeChatのQRコードをスキャンしてお問い合わせください。 

WhatsAPP WeChat

スキャン

前へ 次ページ
無料見積もりプラン

ロード...

购物车

X

我的足迹

X
キーワードウォーター・チラー喜びの瓶詰め ウォーター・チラーウォーターチラー