Search Search all

Heater and Chiller

ClassificationIndustry News 158

Heater and Chiller

 

Heater and chiller is used for refrigeration and heating temperature control in experiments that have certain temperature requirements such as pharmaceuticals, chemicals, biology, and laboratories. The heater and chiller adopts the PID algorithm to control the temperature by controlling the fluid circulation, so the heat transfer medium is also indispensable. Then, what should the heater and chiller pay attention to when emptying and adding liquid?

Precautions for heater and chiller when emptying and adding liquid:

1. When emptying and adding liquid, prepare various tools, wear rubber gloves, goggles, etc., and take necessary protective measures;

2. When selecting the heat transfer medium of the heater and chiller, it is necessary to correspond to the heat transfer oil suitable for the equipment model and temperature range, because the heat transfer oil type is different, the temperature range, viscosity, effect, etc. are different, and the fully enclosed equipment is in operation. There will be no water mist in the medium, and there will be no yellowish brown;

3. When adding heat transfer oil to the heater and chiller, be careful not to pour in the sediment at the bottom of the oil tank;

4. Pay attention to the display part of the observation period during the liquid filling process to prevent entering the electrical cabinet and avoid overflow and damage to the equipment;

5. Pay attention when adding liquid, open the cover counterclockwise when filling, insert the funnel and inject heat-conducting medium, so that the liquid is filled to the expansion liquid level;

6. The heater and chiller needs to empty the air, open the exhaust valve counterclockwise, and the liquid level does not drop after repeated guidance, which means that the internal air has been basically emptied;

7. After normal use, it can run for about half an hour to empty and fill.

The heater and chiller can directly refrigerate at high temperature, and the fully enclosed circulation pipeline does not need to replace the medium, which is more convenient to use.

 

Customized Solutions For Your Business


Cooling and Heating Systems (SUNDI series)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -40 ~ +200°C series -10 ~ +200°C series -25 ~ +200°C series -25 ~ +300°C series -45 ~ +250°C series -45 ~ +300°C series -60 ~ +250°C series -60 ~ +300°C series -70 ~ +250°C series -80 ~ +250°C series-90 ~ +250°C series -100 ~ +100°C series -25 ~ +200°C one machine for two reactors -40 ~ +200°C one machine for two reactors
Cooling Capacityup to 3kWup to 15kWup to 200kWup to 200kWup to 200kWup to 25kWup to 60kWup to 25kWup to 15kWup to 80kWup to 80kWup to 80kWup to 10*2kWup to 10*2kW

 


Cooling and Heating Systems (WTD series)

(Micro channel / tube reactors specialized)

Temperature Control Range: -70°C to +300°C

Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)

 

Temperature range -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Cooling Capacityup to 7.5kWup to 5.5kWup to 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Temperature range -45°C ~ +250°C series -85°C ~ +200°C series -60°C ~ +200°C series
Cooling Capacityup to 25kWup to 25kWup to 60kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Temperature range -20°C ~ +80°C series -45°C ~ +80°C series -60°C ~ +80°C series -80°C ~ +80°C series
Flow Control7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Cooling and Heating Circulators

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -25°C ~ +200°C series -45°C ~ +250°C series
Cooling Capacityup to 15kWup to 15kW

 


Heating Circulators

Temperature Control Range: +50°C to +300°C

Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.

Temperature range +50°C ~ +200°C  (UC series) +50°C ~ +300°C  (UC series) +50°C ~ +300°C  (UST series)
Heating Capacityup to 38kWup to 200kWup to 95kW

 


TCU Multi-reactors Temperature Control System

Temperature Control Range: -120°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Temperature range -45°C ~ +250°C series -120°C ~ +250°C seriesCustomized Temperature Control SystemRT+10°C ~ +135°C
Heating Capacityup to 80kWup to 80kWCustomup to 300kW

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller