1. When the industrial chiller is running with high efficiency, choosing the appropriate lifting point at the position of the lifting point can ensure better air circulation effect. The installation position of the industrial chiller should be carefully observed. If the ventilation effect of the position is good, and all the connection positions are relatively firm, the enterprise can open the equipment for testing. The lifting point has a great influence on the working efficiency of the industrial chiller, so enterprises need to pay attention.

2. No matter whether the semi-enclosed or fully enclosed industrial chiller is working normally, oil separation must be carried out after installation. The amount of oil in the oil separation equipment is limited. During the operation, the temperature of the oil in the industrial chiller oil separation equipment must be strictly controlled. In the cooling environment below -15°C to 20°C, the industrial chiller is required to use refrigerant oil suitable for low temperature environment. When the oil temperature is normal temperature, no strict control is required, just keep the oil separator stable.

3. Whether the pipeline interface is complete, there are many pipelines used in industrial chillers, especially compressors, exhaust valves, etc. If there is a problem with the pipeline installation, it will affect the normal operation of the industrial chiller. An effective distance of 2 meters must be maintained between the condenser tube and the compressor tube to prevent the condenser from not working properly due to too small distance.

4. If the compressor is not installed correctly, vibration will occur during operation and the copper pipe will be damaged. The leakage of the refrigeration medium will affect the normal operation of the industrial cooling water system.

Running an industrial chiller effectively requires safe installation of equipment. Carefully check the safety and quality of industrial chillers to ensure that all auxiliary equipment operates normally, providing a high-quality low-temperature environment for enterprises. So as to achieve the effect of prolonging the service life of industrial chillers and reduce the impact of various faults on the production of enterprises.

Somos un fabricante profesional de equipos de control de temperatura, el apoyo a los servicios personalizados, por favor consúltenos para más detalles

 


enfriador de agua de baja temperatura

Enfriadoras de agua

Rango de control de temperatura: -150°C a +50°C

 


sistema de refrigeración y calefacción

Sistemas dinámicos de control de la temperatura

Rango de control de temperatura: -120°C a +350°C

 

 


sistema de refrigeración de la batería

Enfriadoras para pruebas de automóviles

Rango de control de temperatura: -40°C a +100°C

 

 


enfriador de pruebas de semiconductores

Enfriadores para pruebas de semiconductores

Rango de control de temperatura: -85°C a +250°C

 

 


congelador industrial

Frigoríficos industriales

Rango de control de temperatura: -150°C a -10°C

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Obtener presupuesto gratuito

cargando...

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua