How to Choose a Suitable Cooling and Heating Temperature Control Systems for the Reactor?
Customers need to consider many factors when purchasing reactor refrigeration heating temperature control equipment, such as heating power, cycle pressure, cooling capacity, flow rate, etc., and various working conditions require different equipment models.
First, clarify the user’s working conditions:
1. First figure out the temperature range and capacity you need. These two values are also factors that affect the price of the all-in-one cooling and heating machine. Prevent the situation that the purchased equipment cannot reach the operating temperature, or the waste of resources caused by excessive power supply.
2. The power of the equipment. Many users only consider the heat dissipation and cooling of the power supply when purchasing the power supply, but do not care about the power of the water pump. If the power of the pump is lower than the flow rate, it cannot meet the requirements of use. If the power of the water pump is too large, it will cause energy loss and increase the cost of use.
Second, what factors should be considered when choosing temperature control equipment?
1. Determine the basic requirements of the reactor
Users have different requirements for temperature control of reactors, material, quantity, inlet temperature, inlet temperature, and precision requirements. Therefore, the corresponding models and sizes also have certain differences. Users need accurate process data, and choose suitable ones based on these data. model.
2. Determine the model of the reactor refrigeration heating temperature control equipment
The heat transfer oil of the reactor temperature control equipment generally adopts a fixed type of heat transfer oil, and the type of reaction medium can be determined according to the temperature requirements of the reactor. According to their own site conditions, make supporting preparations. For some special environments, the isolated explosion-proof type can also be customized according to the corresponding requirements, and there are corresponding explosion-proof grades.
3. Determine the parameter configuration of the device
After the user provides the manufacturer with accurate operating data, the manufacturer will provide the corresponding cooling and heating temperature control scheme after calculation. In the scheme, the model and parameter configuration will be selected. The user can see the brand of each accessory in the parameter configuration. After the calculation, the corresponding cooling and heating control scheme will be provided. Some accessories have a variety of brands to choose from. If users have requirements, they can contact to modify. Generally, it is a standard configuration, but it can also be customized.
After determining all the parameters, we have to choose the manufacturer. The price is only a unilateral factor, and we should not blindly seek cheap prices. There are many factors to be considered in the selection of reactor temperature control equipment, and the size of the environment where the equipment is placed should also be considered, and the corresponding ventilation position should be reserved for placing the equipment.
Sistemas dinámicos de control de la temperatura (soporte de personalización)
Sistemas de refrigeración y calefacción (serie SUNDI) (Diseños a medida)
Rango de control de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | -25 ~ +200°C una máquina para dos reactores | -40 ~ +200°C una máquina para dos reactores |
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | hasta 10*2 kW | hasta 10*2 kW |
Sistemas de refrigeración y calefacción (serie WTD) (Diseños a medida)
(Microcanales / reactores tubulares especializados)
Rango de control de temperatura: de -70°C a +300°C
Diseño especializado para microcanal (pequeña capacidad de retención de líquido, gran capacidad de intercambio de calor, sistema de circulación de alta caída de presión)
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW |
Cooling and Heating Systems (TES series) (Diseños a medida)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperatura | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Capacidad de refrigeración | 0,3 ~ 25 kW | 0,25 ~ 25 kW | 3 ~ 60kW |
Cooling and Heating Machines (LTS series) (Diseños a medida)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperatura | Serie -20°C ~ +80°C | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Control de caudal | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de refrigeración y calefacción (Diseños a medida)
Rango de control de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C |
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW |
Termostatos de circulación (Diseños a medida)
Rango de control de temperatura: +50°C a +300°C
Nota: La serie UC puede controlar la temperatura del medio de transferencia de calor. La serie UST no solo puede controlar la temperatura del medio de transferencia de calor, sino también la temperatura del material de reacción.
Temperatura | +50°C ~ +170°C (serie UC) | +50°C ~ +300°C (serie UC) | +50°C ~ +300°C (serie UST) |
Capacidad de calefacción | 5,5 ~ 15 kW | 3,5 ~ 130 kW | 3,5 ~ 95 kW |
TCU Sistema de control de temperatura multirreactores (Diseños a medida)
Rango de control de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C |
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW |