Heater Chiller Circulator
Heater chiller circulator is a temperature control device suitable for connecting reactors in the pharmaceutical, chemical, laboratory and other industries for refrigeration and heating reactions, and is used in different reaction kettles.
First, the characteristics of the heater chiller circulator:
The heater chiller circulator adopts a fully closed system to prolong the life of the heat transfer liquid. It has a very wide temperature range and does not need to replace the liquid medium. During the reaction process of cooling and heating, there is a need for cooling and heating process control, which can control the material temperature in the reactor. The program temperature control mode can be selected, and the temperature difference between the heat transfer medium and the material of the heater chiller circulator can also be set. In addition, the machine is equipped with a multi-function alarm system and functions. It adopts a plate heat exchanger, which takes up less space and has high heat exchange efficiency.
If you need to control the temperature of multiple reactors, you can choose multiple reactor cooling and heating temperature control systems. If it is a one-to-two system, or one to multiple systems, you can choose to install two independent reactors inside the heater chiller circulator. The circulation system, refrigeration system, heating system, shared electrical system, and expansion system can save a certain amount of cost and reduce the enterprise budget.
Second, the selection of heater chiller circulator:
The heater chiller circulator is a constant temperature equipment used to heat and control the temperature of the reactor. When selecting equipment, the two important parts are heating power and pump power. This is related to the accuracy of the reactor temperature. To select power, the following parameters need to be provided.
1. Calculate the heating power according to the size, process requirements and weight of the reactor, and the volume of the reactor jacket or coil;
2. The temperature that the material needs to reach, the time required for cooling to this temperature, the size of the inlet and outlet of the reactor jacket, and whether refrigeration or explosion-proof is required for selection;
3. What is the material reacted in the reactor, and what is the specific heat of the material;
4. What kind of reaction does the material belong to during the reaction process? Is it an exothermic reaction or an endothermic reaction? If it is an exothermic reaction, a cooling system is required.
5. Air-cooled and water-cooled equipment can be provided.
The heater chiller circulator is a temperature control device that heats or cools the reactor jacket or coil to meet the production process requirements, and meets the process temperature and accuracy requirements set during the reaction process of the reactor.
Sistemas dinámicos de control de la temperatura (soporte de personalización)
Sistemas de refrigeración y calefacción (serie SUNDI) (Diseños a medida)
Rango de control de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -10 ~ +150°C | Serie -25 ~ +200°C | Serie -25 ~ +300°C | Serie -45 ~ +250°C | Serie -45 ~ +300°C | Serie -60 ~ +250°C | Serie -60 ~ +300°C | Serie -70 ~ +250°C | Serie -80 ~ +250°C | Serie -90 ~ +250°C | Serie -100 ~ +100°C | -25 ~ +200°C una máquina para dos reactores | -40 ~ +200°C una máquina para dos reactores |
Capacidad de refrigeración | 1,5 ~ 15 kW | 1 ~ 200 kW | 1 ~ 200 kW | 0,45 ~ 200 kW | 0,9 ~ 25 kW | 0,25 ~ 60 kW | 0,75 ~ 25 kW | 0,4 ~ 15 kW | 0,3 ~ 80 kW | 0,2 ~ 80 kW | 0,45 ~ 80 kW | hasta 10*2 kW | hasta 10*2 kW |
Sistemas de refrigeración y calefacción (serie WTD) (Diseños a medida)
(Microcanales / reactores tubulares especializados)
Rango de control de temperatura: de -70°C a +300°C
Diseño especializado para microcanal (pequeña capacidad de retención de líquido, gran capacidad de intercambio de calor, sistema de circulación de alta caída de presión)
Temperatura | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidad de refrigeración | 1,1 ~ 7,5 kW | 1,5 ~ 5,5 kW | 11 ~ 50kW |
Cooling and Heating Systems (TES series) (Diseños a medida)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperatura | Serie -45°C ~ +250°C | Serie -85°C ~ +200°C | Serie -60°C ~ +200°C |
Capacidad de refrigeración | 0,3 ~ 25 kW | 0,25 ~ 25 kW | 3 ~ 60kW |
Cooling and Heating Machines (LTS series) (Diseños a medida)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperatura | Serie -20°C ~ +80°C | Serie -45°C ~ +80°C | Serie -60°C ~ +80°C | Serie -80°C ~ +80°C |
Control de caudal | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de refrigeración y calefacción (Diseños a medida)
Rango de control de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -25°C ~ +200°C | Serie -45°C ~ +250°C |
Capacidad de refrigeración | 1 ~ 15 kW | 0,25 ~ 15 kW |
Termostatos de circulación (Diseños a medida)
Rango de control de temperatura: +50°C a +300°C
Nota: La serie UC puede controlar la temperatura del medio de transferencia de calor. La serie UST no solo puede controlar la temperatura del medio de transferencia de calor, sino también la temperatura del material de reacción.
Temperatura | +50°C ~ +170°C (serie UC) | +50°C ~ +300°C (serie UC) | +50°C ~ +300°C (serie UST) |
Capacidad de calefacción | 5,5 ~ 15 kW | 3,5 ~ 130 kW | 3,5 ~ 95 kW |
TCU Sistema de control de temperatura multirreactores (Diseños a medida)
Rango de control de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperatura | Serie -45°C ~ +250°C | Serie -120°C ~ +250°C | Sistema de control de temperatura personalizado | RT+10°C ~ +135°C |
Capacidad de calefacción | 25 ~ 80 kW | 25 ~ 80 kW | A medida | 25 ~ 300 kW |