Cryogenic Cooling System
In fact, how often to replace the water in the cryogenic cooling system depends on your operating environment and water quality. Let’s talk about how often to replace the circulating water under what circumstances.
1. If your cryogenic cooling system is used in a good environment, such as an independent space, laboratory, and surroundings without impurities and pollution, it can generally be replaced every six months or a year.
2. If your cryogenic cooling system is used in a harsh environment, such as serious pollution and poor environment, we suggest that you change the water once a month, and at the same time, it is recommended that you add anti-scaling agent to reduce the generation of scale. Avoid causing blockage of waterways.
3. If your cryogenic cooling system is running under normal conditions, it usually only needs to be replaced once every three months. At the same time, it is also necessary to regularly clean the dust on the dust filter and the condenser to ensure that the cryogenic cooling system can operate effectively.
Note: If your production company allows it, it is recommended that you use clean tap water, so that it can be recycled back and forth without frequent replacement, and it can also effectively reduce the pipeline blockage caused by impurities in the water to the cryogenic cooling system.
Soluciones personalizadas para su empresa
Refrigeradores de baja temperatura (por agua y por aire)
Rango de control de temperatura: -150°C a -5°C
Estamos especializados en la producción de refrigeradores de baja temperatura con un rango de control de temperatura de hasta -150°C, que pueden satisfacer las necesidades de refrigeración de diferentes industrias.
Temperatura | Serie -25°C ~ -5°C | Serie -45°C ~ -10°C | Serie -60°C ~ -10°C | Serie -80°C ~ -30°C | Serie -110°C ~ -50°C |
Capacidad de refrigeración | hasta 360 kW | hasta 360 kW | hasta 360 kW | hasta 270 kW | hasta 180 kW |
Enfriadoras de recirculación (Refrigeración por agua y por aire)
Rango de control de temperatura: -120°C a +30°C
Nuestro enfriador de recirculación adopta tecnología de refrigeración de baja temperatura, la temperatura es tan baja como -120℃, y varios accesorios son personalizables.
Temperatura | Serie -25°C ~ +30°C | Serie -45°C ~ +30°C | Serie -60°C ~ -20°C | Serie -80°C ~ -20°C | Serie -120°C ~ -70°C |
Capacidad de refrigeración | hasta 38 kW | hasta 12 kW | hasta 7,2 kW | hasta 7,2 kW | hasta 8,6 kW |
Refrigeradores de temperatura ambiente / Refrigeradores pequeños
Rango de control de temperatura: +5°C a +50°C
El enfriador puede utilizarse ampliamente en diversas industrias y laboratorios, y admite diseños personalizados.
Temperatura | -18°C ~ +30°C | Serie +5°C ~ +35°C |
Capacidad de refrigeración | hasta 0,9 kW | hasta 50 kW |
Equipos frigoríficos de refrigeración directa
Rango de control de temperatura: -120°C a -10°C
Es adecuado para lugares con poca superficie de intercambio de calor y gran intercambio de calor.
Temperatura | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Potencia del compresor | hasta 8CV | hasta 8CV*2 | hasta 45 CV*3 |
Enfriadoras de temperatura ultrabaja de refrigeración directa
Rango de control de temperatura: -150°C a -110°C
Soluciones personalizadas para su empresa.
Temperatura | -150°C ~ -110°C |
Capacidad de refrigeración | hasta 11 kW |
Refrigeradores de tornillo
Refrigeradores de tornillo de baja temperatura y refrigeradores de tornillo a temperatura ambiente
Soluciones personalizadas para su empresa.
Temperatura | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidad de refrigeración | hasta 1027 kW (compresor único) | hasta 2134 kW (compresor doble) | hasta 934 kW (compresor único) | hasta 1940 kW (compresor doble) | hasta 467 kW (compresor único) | hasta 497 kW (compresor único) |