Suche Alle suchen

What should be Paid Attention to When Starting up the Reactor Refrigeration and Heating System?

KlassifizierungIndustrie-Nachrichten 148

What should be Paid Attention to When Starting up the Reactor Refrigeration and Heating System?

 

The reactor refrigeration and heating system adopts a fully enclosed pipeline design and a plate heat exchanger, which reduces the demand for heat transfer fluid and improves the heat utilization rate of the system to achieve rapid temperature rise and fall. The heat transfer medium is in a closed system with an expansion vessel. The heat conduction medium in the expansion vessel does not participate in the circulation. Whether it is high temperature or low temperature, the temperature of the expansion tank is from room temperature to 60°C, which can reduce the absorption of water and volatilization of the heat transfer medium during operation. risk.

It adopts compressor refrigeration and high-pressure linkage heating technology, or direct heating with heating wire, and is controlled in real time by the advanced control system to meet the requirements of using cold water or hot water, maintain the water temperature at the set state, low vibration, low noise, and high energy efficiency ratio. The temperature control range is -150°C-350°C, with cooling and heating functions to meet different temperature requirements under different needs. Adopting compressor combination technology, the refrigeration circuit is started in a time-sharing dislocation, reducing interference to the power grid, stably exerting the performance of the compressor, and fully automatic temperature control, which can meet continuous operation 24 hours a day.

What should be paid attention to when the reactor refrigeration and heating system is started for the first time?

1. When starting up for the first time, press the power button and there is no display: the fuse in the power socket is broken, unplug the power cord, take out the fuse and replace it with a new one; Put the air switch in the “ON” state to solve the problem.

2. After turning on the machine for the first time or after a long period of non-starting, turn on the “circulation” button, the water pump does not turn or there is no circulating water, and the “circulation” indicator light is on: check whether there is a dead knot in the external hose, and untie the dead knot; there is a lot of air or scale inside the pump , or the long-term non-use of the water pump leads to a decrease in the lubrication of the rotor, making it difficult to start the water pump. It is necessary to unplug the power supply, open the cover of the device, remove the rubber disc directly behind the motor rotor, use a flat-head screwdriver to hold the motor rotor and move it left and right, and the motor can be restarted; directly replace the water pump.

3. The refrigeration system does not start: the refrigeration button is not turned on, turn on the refrigeration button; the circuit board is faulty, replace the circuit board; the compressor is faulty, and a professional inspection is required.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


Kühl- und Heizsysteme (Serie SUNDI)

Temperaturregelbereich: -120°C bis +350°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Automobilindustrie, Halbleiter- und Elektrotests, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -40 ~ +200°C Serie -10 ~ +200°C Serie -25 ~ +200°C Serie -25 ~ +300°C Serie -45 ~ +250°C Serie -45 ~ +300°C Serie -60 ~ +250°C Serie -60 ~ +300°C Serie -70 ~ +250°C Serie -80 ~ +250°CSerie -90 ~ +250°C Serie -100 ~ +100°C -25 ~ +200°C eine Maschine für zwei Reaktoren -40 ~ +200°C eine Maschine für zwei Reaktoren
Kühlleistungbis zu 3kWbis zu 15kWbis zu 200kWbis zu 200kWbis zu 200kWbis zu 25kWbis zu 60kWbis zu 25kWbis zu 15kWbis zu 80kWbis zu 80kWbis zu 80kWbis zu 10*2kWbis zu 10*2kW

 


Kühl- und Heizsysteme (WTD-Serie)

(Mikrokanal / Röhrenreaktoren spezialisiert)

Temperaturregelbereich: -70°C bis +300°C

Spezielles Design für Mikrokanäle (geringe Flüssigkeitsspeicherkapazität, starke Wärmeaustauschkapazität, Zirkulationssystem mit hohem Druckabfall)

 

Temperaturbereich -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Kühlleistungbis zu 7,5 kWbis zu 5,5 kWbis zu 50kW

 


Kühl- und Heizsysteme (TES-Serie)

Temperaturregelbereich: -85°C ~ +250°C

Temperaturregelungsgenauigkeit: ± 0,3°C

 

 

Temperaturbereich Serie -45°C ~ +250°C Serie -85°C ~ +200°C Serie -60°C ~ +200°C
Kühlleistungbis zu 25kWbis zu 25kWbis zu 60kW

 


Kühl- und Heizmaschinen (LTS-Serie)

Temperaturregelbereich: -80°C bis +80°C

Es wird häufig in der Halbleiterindustrie eingesetzt, um die Temperatur der Reaktionskammer, der Heizplatte und des nicht brennbaren Wärmeträgers zu regeln.

 

 

Temperaturbereich -20°C ~ +80°C Reihe Serie -45°C ~ +80°C Serie -60°C ~ +80°C Serie -80°C ~ +80°C
Durchflusskontrolle7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Umwälzpumpen für Kühlung und Heizung

Temperaturregelbereich: -45°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -25°C ~ +200°C Serie -45°C ~ +250°C
Kühlleistungbis zu 15kWbis zu 15kW

 


Heizungsumwälzpumpen

Temperaturregelbereich: +50°C bis +300°C

Hinweis: Die UC-Serie kann die Temperatur des Wärmeträgermediums regeln. Die UST-Serie kann nicht nur die Temperatur des Wärmeträgermediums, sondern auch die Temperatur des Reaktionsmaterials regeln.

Temperaturbereich +50°C ~ +200°C (UC-Serie) +50°C ~ +300°C (UC-Serie) +50°C ~ +300°C (UST-Serie)
Heizleistungbis zu 38kWbis zu 200kWbis zu 95 kW

 


TCU Multireaktoren Temperaturkontrollsystem

Temperaturregelbereich: -120°C bis +250°C

Anwendung: Verschiedene Reaktoren (Mikrokanäle, Glas, ummantelte Reaktoren usw.), Destillations- oder Extraktionssysteme, Labor, Universität, Forschungsinstitut, Luft- und Raumfahrt, Chemie, Pharmazie, Petrochemie, Biochemie, Medizin, Krankenhaus, F&E-Werkstatt, Luft- und Raumfahrt, Biologie und andere Industrien.

Temperaturbereich Serie -45°C ~ +250°C -120°C ~ +250°C ReiheKundenspezifisches TemperaturkontrollsystemRT+10°C ~ +135°C
Heizleistungbis zu 80kWbis zu 80kWBenutzerdefiniertbis zu 300kW

 

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz