Water Chiller Factory: Air Cooled Chillers and Water Cooled Chillers

 

Water-cooled chillers and air-cooled chillers have their own characteristics. Users who need to use chillers need to make comprehensive choices according to actual conditions such as different environments, spaces, required cooling capacity, and different areas.

1. Chiller cooling method

Die air-cooled chiller adopts the air-cooling method, which saves the cooling water tower, circulating water pump and pipeline system required by the cooling water system, and avoids scaling of the condenser and blockage of water pipes caused by poor water quality. Among the current chiller products, Water Resources is the most economical, easy to maintain and repair chiller. The one-time investment of air-cooled chillers is higher than that of water-cooled chillers, but the annual operating cost is lower than that of water-cooled chillers. In addition, the air-cooled chiller is noisy, and the hot air discharged is directly distributed at the installation position of the chiller. Therefore, there are requirements for the ambient temperature of the operation, and it can only be installed outdoors.

Water-cooled chillers must be equipped with cooling water towers and circulating water pumps before they can be used. Compared with the plastic industry, cooling water towers can be used in areas with lower temperatures or for heat dissipation in spring, autumn, and winter, so water-cooled chillers have advantages. However, in an open cooling circulating water system, when the cooling water absorbs heat and contacts with the air, the dissolved oxygen and turbidity in the water will increase, which will easily cause corrosion, scaling, and the growth of bacteria. If the water quality is not treated, the chiller will be seriously damaged, the heat exchange efficiency will be greatly reduced, and energy will be wasted. Therefore, it is necessary to carry out corrosion inhibition, scale inhibition, sterilization and algae elimination for the water system.

2. Chiller price

Both water-cooled und luftgekühlte Kältemaschinen can be used for lower power systems. Most high-power units use water-cooled chillers. As far as the main engine is concerned, water-cooled chillers are cheaper than air-cooled chillers, but with cooling towers and circulating water pumps, the price is not low. However, in the past few years, air-cooled chillers have been widely used in central air-conditioning system engineering. It can be seen that the price is not a problem, the key is to meet the needs of the industry.

 


Niedertemperaturkühler

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperaturregelbereich: -150°C bis -5°C

Anwendung: Verschiedene Reaktoren, Destillations- oder Extraktionssysteme, Laboratorien, Forschungsinstitute, chemische, pharmazeutische, petrochemische, biochemische, medizinische Einrichtungen, Krankenhäuser, F&E-Werkstätten, Halbleitertests, Luft- und Raumfahrt, biologische und andere Industrien.

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°C Serie -110°C ~ -50°C
Kühlleistungbis zu 360 kWbis zu 360 kWbis zu 360 kWbis zu 270kWbis zu 180kW

 


Umwälzkühler

Gekühlte Umwälzpumpen (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Anwendung: Verschiedene Reaktoren, Destillations- oder Extraktionssysteme, Laboratorien, Forschungsinstitute, chemische, pharmazeutische, petrochemische, biochemische, medizinische Einrichtungen, Krankenhäuser, F&E-Werkstätten, Halbleitertests, Luft- und Raumfahrt, biologische und andere Industrien.

Temperaturbereich Serie -25°C ~ +30°C -45°C ~ +30°C Reihe Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistungbis zu 38kWbis zu 12kWbis zu 7,2 kWbis zu 7,2 kWbis zu 8,6 kW

 


Kaltwassersatz

Raumtemperatur-Kühlgeräte / Kleinkühlgeräte

Temperaturregelbereich: +5°C bis +50°C

Anwendung: Verschiedene Reaktoren, Destillations- oder Extraktionssysteme, Laboratorien, Forschungsinstitute, chemische, pharmazeutische, petrochemische, biochemische, medizinische Einrichtungen, Krankenhäuser, F&E-Werkstätten, Halbleitertests, Luft- und Raumfahrt, biologische und andere Industrien.

Temperaturbereich -18°C ~ +30°C +5°C ~ +35°C Reihe
Kühlleistungbis zu 0,9 kWbis zu 50kW

 


 

Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte

Temperature Control Range: -150°C to -110°C, customized solutions for your business.

 

Temperaturbereich -150°C ~ -110°C
Kühlleistungbis zu 11kW

 

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz