The Reasons Why the Water Pump of the Chiller is not Running

KlassifizierungIndustrie-Nachrichten 371

 

The Reasons Why the Water Pump of the Chiller is not Running

 

As we all know, the water pump in the chiller is used to pump water. If the water pump of the chiller can not pump out water, it will be a very troublesome thing. The following is an explanation from the LNEYA refrigeration manufacturer. Why is the water pump in the chiller installed? There are several reasons why water cannot be pumped out normally:

Reasons why the water pump in the chiller does not pump out water after installation:

1. The pump speed is too low

The mechanical failure of the pump itself, the loosening of the fastening nut between the impeller and the pump shaft or the deformation and bending of the pump shaft, cause the impeller to move more, directly rub against the pump body, or damage the bearing, which may reduce the speed of the pump.

2. Human factors

Some users randomly add another motor to drive because the original motor is damaged, resulting in the consequence of low flow rate and low lift or even no water supply.

3. Engine maintenance failure

The motor is demagnetized due to the burning of the winding, the change of the number of turns of the winding, the wire diameter, and the wiring method during the maintenance, or the factors that the fault is not completely eliminated during the maintenance will also change the speed of the pump.

4. The suction stroke is too large

Some water sources are deep, and some of the water sources have relatively flat peripheral terrain, and the allowable suction lift of the pump is ignored, resulting in the result of little or no water absorption at all. It should be known that the vacuum degree that can be established at the suction port of the pump is limited. The suction lift of an absolute vacuum is about 10 meters high, and it is impossible for the pump to establish an absolute vacuum. And if the vacuum is too large, it is easy to vaporize the water in the pump, which is not good for the work of the pump. Therefore, each centrifugal pump has its maximum allowable suction lift, which is generally between 3-8.5 meters. When installing the water pump, it must not only be convenient and simple.

5. The resistance loss in the inlet and outlet pipes of the water flow is too large

Some users have measured that although the vertical distance from the reservoir or water tower to the water surface of the water source is slightly smaller than the pump head, the amount of water lifted is still small or cannot be lifted. The reason is often that the pipeline is too long, the water pipeline has many bends, and the resistance loss of the water flow in the pipeline is too large. Under normal circumstances, the resistance of a 90-degree elbow is larger than that of a 120-degree elbow, and the lift of each 90-degree elbow will lose about 0.5-1 meter, and the resistance of each 20-meter pipeline can cause the lift to lose about 1 meter. In addition, some users also choose the diameter of the pump inlet and outlet pipes, which also has a certain impact on the lift.

In addition, the installation of the water pump in the chiller will also be affected by the following other factors:

The bottom valve cannot be opened, the impeller is seriously worn, the filter screen of the bottom valve is blocked or the bottom valve is buried in the sludge layer in the latent water, causing the filter screen to be blocked. The failure or blockage of the gate valve and the check valve will cause the flow rate to decrease or even not pump water, and the leakage of the outlet pipeline will also affect the water pumping amount.

Wir sind ein professioneller Hersteller von Temperaturkontrollgeräten und unterstützen kundenspezifische Dienstleistungen, bitte uns konsultieren für Details!

 


Low Temperature Water Cooled Chillers

Temperaturregelbereich: -150°C bis -5°C

Anwendung: Verschiedene Reaktoren, Destillations- oder Extraktionssysteme, Laboratorien, Forschungsinstitute, chemische, pharmazeutische, petrochemische, biochemische, medizinische Einrichtungen, Krankenhäuser, F&E-Werkstätten, Halbleitertests, Luft- und Raumfahrt, biologische und andere Industrien.

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°C Serie -110°C ~ -50°C Serie -150°C ~ -110°C
Kühlleistungbis zu 360 kWbis zu 360 kWbis zu 360 kWbis zu 270kWbis zu 180kWbis zu 11kW

 


Air Cooled Recirculating Chillers

Temperaturregelbereich: -120°C bis 30°C

Anwendung: Verschiedene Reaktoren, Destillations- oder Extraktionssysteme, Laboratorien, Forschungsinstitute, chemische, pharmazeutische, petrochemische, biochemische, medizinische Einrichtungen, Krankenhäuser, F&E-Werkstätten, Halbleitertests, Luft- und Raumfahrt, biologische und andere Industrien.

Temperaturbereich Serie -25°C ~ 30°C -45°C ~ 30°C Serie Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistungbis zu 38kWbis zu 12kWbis zu 7,2 kWbis zu 7,2 kWbis zu 8,6 kW

 


Normaltemperatur-Kühlgeräte

Temperaturregelbereich: +5°C bis +50°C

Anwendung: Verschiedene Reaktoren, Destillations- oder Extraktionssysteme, Laboratorien, Forschungsinstitute, chemische, pharmazeutische, petrochemische, biochemische, medizinische Einrichtungen, Krankenhäuser, F&E-Werkstätten, Halbleitertests, Luft- und Raumfahrt, biologische und andere Industrien.

Temperaturbereich -18°C ~ +30°C +5°C ~ +50°C Reihe
Kühlleistungbis zu 0,9 kWbis zu 50kW

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz