Suche Alle suchen

Air Cooled Unit

KlassifizierungIndustrie-Nachrichten 187

Air Cooled Unit

 

In the industrial refrigeration industry, friends often ask how to choose an air cooled unit. After comparing the chiller solutions of two or three companies, they feel that they are similar, but the prices are very different! Therefore, it is really necessary for enterprise producers to understand the basic selection common sense of air cooled unit. So how can you choose the air cooled unit solution that suits you for enterprise production? Below we will explain to you from six aspects.

1. How many parameters do you need?

For example, how much material and how long do you need to cool down to how much ℃? This is an important reference for us to choose the type of air cooled unit. In addition to the temperature difference, other cooling parameters include water flow, water pressure, cooling time, and material volume. These parameters are used to calculate the cooling capacity required by the production equipment.

2. Consider solutions with low energy consumption

If you are a large air cooled unit, pay attention to the energy consumption and choose a chiller scheme that comprehensively utilizes electric heating and cooling.

3. Do you need other chillers to work together?

See if your business needs multiple air cooled units, such as cold storage, which require stable and continuous cooling. When a certain air cooled unit fails, other chillers are needed to work instead. According to the production situation of your enterprise, explain it to the manufacturer.

4. Are there any environmental protection requirements?

Air cooled unit work will also cause some environmental problems, such as whether the refrigerant is toxic, whether the operating noise is loud, and whether it will affect the surrounding environment of the enterprise. When selecting equipment, the requirements in this regard must be clearly explained to the manufacturer .

5. Cooling water quality requirements

The water quality of the cooling water will affect the cleanliness of the pipeline, especially the evaporator. Poor cooling water quality will accelerate the scaling and corrosion of the pipeline, resulting in the blockage and damage of the evaporator. Please inform the manufacturer when selecting the model.

6. Other special requirements such as explosion-proof and vibration

The air cooled unit often works in a harsh environment and is often exposed to special substances such as flammable dust and explosive gas. Then the enterprise’s requirements for explosion-proof and shock-proof will also increase. At this time, it is necessary to consult the relevant technical personnel of the enterprise, whether the working environment of the chiller is flammable and explosive, and consult with the chiller manufacturer, whether the air cooled unit can be used for explosion-proof treatment, explosion-proof level For how much, the overall cooling needs match the appropriate chiller solution.

If your company needs to be equipped with customized air cooled units during the production process, you can consider the actual situation of your company in advance, start from the above six points, formulate a demand plan for chillers, and choose to cooperate with air cooled unit manufacturers with complete brand qualifications and reputations.

 

Maßgeschneiderte Lösungen für Ihr Unternehmen


 

Niedertemperaturkühler

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperaturregelbereich: -150°C bis -5°C

Wir haben uns auf die Herstellung von Niedertemperaturkältemaschinen mit einem Temperaturregelbereich von bis zu -150°C spezialisiert, die den Kühlbedarf verschiedener Branchen decken.

Temperaturbereich Serie -25°C ~ -5°C Serie -45°C ~ -10°C Serie -60°C ~ -10°C Serie -80°C ~ -30°C Serie -110°C ~ -50°C
Kühlleistungbis zu 360 kWbis zu 360 kWbis zu 360 kWbis zu 270kWbis zu 180kW

 


Umwälzkühler

Rückkühler (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Unser Rückkühler arbeitet mit Niedertemperatur-Kältetechnik, die Temperatur beträgt bis zu -120℃, und verschiedene Zubehörteile sind anpassbar.

Temperaturbereich Serie -25°C ~ +30°C -45°C ~ +30°C Reihe Serie -60°C ~ -20°C Serie -80°C ~ -20°C Serie -120°C ~ -70°C
Kühlleistungbis zu 38kWbis zu 12kWbis zu 7,2 kWbis zu 7,2 kWbis zu 8,6 kW

 


Kaltwassersatz

Raumtemperatur-Kühlgeräte / Kleinkühlgeräte

Temperaturregelbereich: +5°C bis +50°C

Die Kältemaschine kann in verschiedenen Industrien und Labors eingesetzt werden und unterstützt kundenspezifische Designs.

Temperaturbereich -18°C ~ +30°C +5°C ~ +35°C Reihe
Kühlleistungbis zu 0,9 kWbis zu 50kW

 


Direktkühlende Maschine

 

Kühlgeräte mit direkter Kühlung

Temperature Control Range: -120°C to -10°C

Er eignet sich für Orte mit kleiner Wärmeaustauschfläche und großem Wärmeaustausch.

 

Temperaturbereich -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Leistung des Kompressorsbis zu 8HPbis zu 8HP*2bis zu 45HP*3

 


 

Direktkühlende Ultra-Niedrigtemperatur-Kühlgeräte

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperaturbereich -150°C ~ -110°C
Kühlleistungbis zu 11kW

 


Schrauben-Kühlanlagen

 

Schrauben-Kühlmaschinen

Niedertemperatur-Schraubenkühlmaschinen und Raumtemperatur-Schraubenkühlmaschinen

Customized solutions for your business.

 

 

Temperaturbereich +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Kühlleistungup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Das Copyright liegt bei lneya-online.com, bitte kontaktieren Sie uns per E-Mail für weitere Informationen: lilia@lneya.com

Oder scannen Sie den unten stehenden WhatsApp- oder WeChat-QR-Code, um uns zu kontaktieren. 

WhatsAPP WeChat

scannen.

Vorherige: Nächste:
Kostenloses Angebot anfordern Plan

Laden...

购物车

X

我的足迹

X
Schlüsselwörter:Freude in Flaschen Kaltwassersatz