The condenser of the compressed air chiller is blown by a fan to dissipate heat. There are five main reasons for high-voltage failures:

1. The condenser of the compressed air chiller is blocked: if the condenser is blocked, it will cause abnormal condensation of high-pressure refrigerant gas in the refrigerant system, causing a large amount of gas to coalesce, resulting in high-voltage failure.

Solution: Clean and remove dirt from the condenser. Please consult the manufacturer for specific methods.

2. Too much refrigerant in the compressed air chiller: Too much refrigerant cannot be condensed into a liquid state, occupying too much area of the condensing pipe, reducing the condensation effect, and increasing the pressure.

Solution: Slowly release some refrigerant on the low pressure side.

3. The opening of the expansion valve of the compressed air chiller is too small: the expansion valve is used to throttle the high-pressure liquid refrigerant into a gaseous state. If the opening is too small, the pressure of the front condenser will be too high.

Solution: Properly increase the opening of the expansion valve.

4. There is air in the compressed air chiller system: This kind of reason often occurs after new equipment or compressor maintenance, and air is mixed into the refrigeration system, so that the air cannot be condensed and remains in the condenser, causing the pressure to rise.

Solution: bleed air through the air separation valve, exhaust port or condenser of the chiller, and consult the chiller manufacturer.

5. Abnormal operation of the condenser fan: This will lead to poor heat dissipation of the condenser, that is, the heat generated inside the refrigeration refrigerant cycle cannot be removed by the fan fan, and then the temperature and pressure will rise, and a high pressure alarm will appear.

Solution: Check and repair the fan, remove the dust and sundries around the fan cover, and clean it with compressed air or water gun after shutdown.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller