chiller 2kw – Low Temperature Control Chillers
As we all know, the temperature control of fiber laser cutting machines is mainly carried out by chillers. As a circulating water equipment, the chiller is responsible for cooling the laser and the cutting head, and is an important part of the fiber laser cutting machine. In order to ensure the stable operation of the fiber laser cutting machine, it is necessary to learn to maintain the chiller regularly. So what should be paid attention to in the maintenance of 2kw chiller?
The maintenance of 2kw chiller should pay attention to the following aspects:
1. Ensure that the air outlet and air inlet of the 2kw chiller are well ventilated, ensure that the operating environment of the fiber optic chiller is below 40°C, and avoid the high temperature alarm of the chiller (especially when the room temperature is too high in summer).
2. Regularly replace the circulating water (once a month). The circulating water should be clean distilled water or pure water.
3. Regularly remove and wash the dust-proof net, clean the dust accumulated on the dust-proof net, and improve the heat dissipation performance of the 2kw chiller.
4. Regularly clean the dust accumulated in the condenser.
5. The water quality and temperature of the circulating water will affect the service life of the laser tube. It is recommended to use deionized water and control the water temperature at about 25°C.
6. Regularly clean the impurities on the filter element of the 2kw chiller. If the filter element is damaged, it should be replaced in time. The replaced filter element must use the standard filter element required by the manufacturer.
Customized Solutions For Your Business
Low Temperature Chillers (Custom Designs)
We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.
Temperature range | -25°C ~ -5°C series | -45°C ~ -10°C series | -60°C ~ -10°C series | -80°C ~ -30°C series | -110°C ~ -50°C series | -150°C ~ -110°C series |
Cooling Capacity | up to 360kW | up to 360kW | up to 360kW | up to 270kW | up to 180kW | up to 11kW |
Recirculating Chillers (Custom Designs)
Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.
Temperature range | -25°C ~ +30°C series | -45°C ~ +30°C series | -60°C ~ -20°C series | -80°C ~ -20°C series | -120°C ~ -70°C series |
Cooling Capacity | up to 38kW | up to 12kW | up to 7.2kW | up to 7.2kW | up to 8.6kW |
Room Temperature Chillers / Small Chillers (Custom Designs)
The chiller can be widely used in various industries and laboratories, and supports customized design.
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C series |
Cooling Capacity | up to 0.9kW | up to 50kW |
Direct Cooling Type Refrigeration Equipments (Custom Designs)
It is suitable for places with small heat exchange area and large heat exchange.
Temperature range | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Compressor Power | up to 8HP | up to 8HP*2 | up to 45HP*3 |
Chillers for Automotive Battery Test (Custom Designs)
Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc.
Temperature range | -25°C ~ +100°C | -40°C ~ +100°C | 0°C ~ +100°C | -40°C ~ +135°C |
Cooling Capacity | up to 38kW | up to 60kW | up to 60kW | up to 60kW |
Temperature / Pressure / Flow can be independently controlled.
1&2: one machine for two groups control.
Temperature range | -40 ~ +100℃ 1&2 | 0 ~ +100℃ 1&2 |
Cooling Capacity | up to 60kW*2 | up to 60kW*2 |
Temperature remains constant, pressure / flow can be independently controlled.
1&3: one machine for three groups control.
1&6: one machine for six groups control.
Temperature range | -40 ~ +100℃ 1&2 | -40 ~ +100℃ 1&3 | -40 ~ +100℃ 1&6 | -20 ~ +100℃ 1&6 | 0 ~ +100℃ 1&2 | 0 ~ +100℃ 1&3 | 0 ~ +100℃ 1&6 |
Cooling Capacity | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW | up to 60kW |
Semiconductor Chillers (TES series) (Custom Designs)
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | up to 25kW | up to 25kW | up to 60kW |
Semiconductor Chillers (LTS series) (Custom Designs)
Suitable for precise temperature control of electronic components. In the manufacture of semiconductor electronic components for harsh environments, the IC packaging assembly and engineering and production testing phases include electronic thermal testing and other environmental testing simulations.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Chillers for Energy Storage(Custom Designs)
Liquid Cooling Solutions For Battery Energy Storage Systems
Temperature range | -45°C ~ +55°C |
Cooling Capacity | up to 45kW |
Screw Chillers (Custom Designs)
Low temperature screw chillers and room temperature screw chillers
Temperature range | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Cooling Capacity | up to 1027kW (Single Compressor) | up to 2134kW (Dual Compressor) | up to 934kW (Single Compressor) | up to 1940kW (Dual Compressor) | up to 467kW (Single Compressor) | up to 497kW (Single Compressor) |