Pesquisar Pesquisar tudo

Refrigerated Industrial Chiller – Custom Chillers

ClassificaçãoNotícias do sector 469

What Is A Chiller:

Today, LNEYA refrigeration manufacturer will explain the working principle of the chiller. In the refrigeration industry, it is divided into air-cooled chillers e water-cooled chillers. According to the compressor, it is divided into screw chillers and scroll chillers. In terms of temperature control, it is divided into low-temperature industrial chillers e normal temperature chillers. , The temperature of the normal temperature unit is generally controlled within the range of 0 degrees -35 ° C. The temperature control of the low temperature unit is generally from 0 degrees to -120 °C (our equipment can reach as low as -150 °C). Because chillers are widely used, the requirements for chillers in various industries are not exactly the same. Its working principle is a multi-functional machine, through compression or heat absorption refrigeration cycle. The chiller consists of four main components: compressor, evaporator, condenser, and expansion valve, so as to achieve the cooling or heating effect of the unit. The following is a brief introduction to the working principle of the chiller.

The Basic Components Of The Refrigeration System

2. Compressor: O compressor é o componente central de todo o sistema de refrigeração e a fonte de energia para a compressão do refrigerante. A sua função é converter a energia eléctrica de entrada em energia mecânica e comprimir o refrigerante.

1. Condensador: Durante o processo de refrigeração, o condensador desempenha o papel de produzir energia térmica e condensar o refrigerante. Depois de o vapor sobreaquecido de alta pressão descarregado do compressor de refrigeração entrar no condensador, todo o calor absorvido durante o processo de trabalho, incluindo o calor absorvido do evaporador e do compressor de refrigeração e na tubagem, é transferido para o meio circundante (água ou ar); o vapor sobreaquecido de alta pressão do refrigerante condensa-se novamente em líquido. (De acordo com os diferentes meios de refrigeração e métodos de refrigeração, os condensadores podem ser divididos em três categorias: condensadores arrefecidos a água, condensadores arrefecidos a ar e condensadores evaporativos).

Liquid accumulator: The liquid accumulator is installed after the condenser and is directly connected to the drain pipe of the condenser. The refrigerant liquid of the condenser should flow into the liquid receiver unimpeded, so that the cooling area of ​​the condenser can be fully utilized. On the other hand, when the heat load of the evaporator changes, the demand of the refrigerant liquid also changes accordingly, and the liquid accumulator plays the role of adjusting and storing the refrigerant at that time. For small refrigeration equipment systems, the liquid receiver is often not installed, but the condenser is used to adjust and store the refrigerant.

Filter drier: In the refrigeration cycle, it is necessary to prevent the entry of moisture and dirt (oil, iron filings, copper filings), etc. The source of moisture is mainly the trace moisture contained in the newly added refrigerant and lubricating oil, or due to the maintenance system. Moisture brought by the ingress of air. If the water in the system is not removed, when the refrigerant passes through the throttle valve (thermal expansion valve or capillary), the water will sometimes freeze into ice due to the drop in pressure and temperature, blocking the channel and affecting the normal operation of the refrigeration device. Therefore, filter driers must be installed in the refrigeration system.

Thermal expansion valve: The thermal expansion valve is not only a flow control valve in the refrigeration system, but also a throttle valve in the refrigeration equipment. It is installed between the drying filter and the evaporator in the refrigeration equipment. at the outlet of the evaporator. Its main function is to throttle and depressurize the high-pressure and normal-temperature refrigerant liquid when it flows through the thermal expansion valve, and turn it into a low-temperature and low-pressure refrigerant wet vapor (mostly liquid, a small part of which is vapor) into the evaporator and vaporize in the evaporator. Absorb heat to achieve the purpose of cooling and cooling.

Evaporator: The evaporator is a heat exchange device that relies on the evaporation (actually boiling) of the refrigerant liquid to absorb the heat of the cooled medium. Its function in the refrigeration system is to absorb heat (or output cooling). In order to ensure that the evaporation process can be carried out stably and lastingly, the evaporating gas must be continuously pumped out by the refrigeration compressor to maintain a certain evaporation pressure.

7. Refrigerante: A maioria dos pequenos chillers industriais utilizados na indústria moderna utiliza R22 ou R12 como refrigerante. O refrigerante é o fluido de trabalho que circula no sistema de refrigeração. A sua principal função é transportar calor e absorver e libertar calor quando o seu estado se altera.

Water Circulation System

The water circulation system is a water pump that pumps water from the water tank to the equipment that the user needs to cool. The chilled water takes away the heat and then the temperature rises, and then returns to the chilled water tank.

Electrical automatic control system:

The electrical automatic control system includes the power supply part and the automatic control part.

The power supply part supplies power to compressors, fans, water pumps, etc. through contactors.

The automatic control part includes thermostat, pressure protection, delay device, relay, overload protection, etc. to achieve automatic start and stop according to the water temperature, protection and other functions.

Industrial Chiller Cooling Characteristics

With the rapid development of modern industrial technology, in order to improve production efficiency, improve product quality, and reduce production costs, the requirements for temperature control in the production process are getting higher and higher.

The general water cooling method (that is, natural water and water tower cooling methods) cannot achieve the purpose of high-precision and high-efficiency temperature control, because both natural water and water tower cooling are inevitably affected by natural temperature, and the water temperature in winter is low in summer. . If the air temperature is 30°C, it is almost impossible for the water temperature to reach 10°C, so it is extremely unstable to control in this way.

The chiller is completely different from the general water cooling equipment, because the chiller has a completely independent refrigeration system, which will never be affected by the temperature and the environment. The purpose of high-efficiency temperature control. The chiller is equipped with an independent water circulation system, and the water in the chiller is recycled, which can save a lot of water.

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
展开更多
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água