Process Water Cooler
I believe everyone knows that industrial chillers can be mainly divided into water-cooled and air-cooled according to different cooling methods. However, even when both have the same cooling capacity, most enterprises prefer to choose process water cooler. So why do companies prefer to choose process water cooler?
Advantages of process water cooler:
1. Compared with the air-cooled type, the process water cooler is safer in operation and more conducive to maintenance and repair.
2. The water tank evaporator has a built-in automatic water replenishment device, which saves the expansion tank in the engineering installation and is convenient for installation and maintenance. It is suitable for special occasions such as large temperature difference and small flow rate.
3. Many process water coolers adopt advanced product design, which can meet the needs of various industrial production to a large extent. The standard setting function keys of many process water coolers can be accurate to three decimal places, and the control and adjustment functions are very significant. , At the same time, many of the condensers of the process water cooler are made of high-efficiency copper tube sleeves and aluminum fins, which are very durable.
4. The cooling effect of the process water cooler is stable, the price is affordable, and the requirements for the installation environment are not high. It is especially suitable for enterprises with high temperature accuracy of the chiller. The basic configuration of the process water cooler is the same as other chillers, mainly composed of four parts, and an internal circulating water pump is added inside. The circulating cooling water continuously provided by the cooling water tower can quickly reach the cooling temperature required by the enterprise.
Chillers de baixa temperatura (Desenhos personalizados)
Somos especializados na produção de refrigeradores de baixa temperatura com uma gama de controlo de temperatura tão baixa como -150°C, que pode satisfazer as necessidades de refrigeração de diferentes indústrias.
Gama de temperaturas | Série -25°C ~ -5°C | Série -45°C ~ -10°C | Série -60°C ~ -10°C | Série -80°C ~ -30°C | Série -110°C ~ -50°C | Série -150°C ~ -110°C |
Capacidade de arrefecimento | 12 ~ 360kW | 6 ~ 180kW | 6 ~ 180kW | 4 ~ 180kW | 2 ~ 120kW | 2,5 ~ 11kW |
Chillers de recirculação (Desenhos personalizados)
Nosso resfriador de recirculação adota tecnologia de refrigeração de baixa temperatura, a temperatura é tão baixa quanto -120 ℃ e vários acessórios são personalizáveis.
Gama de temperaturas | Série -25°C ~ +30°C | Série -45°C ~ +30°C | Série -60°C ~ -20°C | Série -80°C ~ -20°C | Série -120°C ~ -70°C |
Capacidade de arrefecimento | 0,8 ~ 30kW | 0,75 ~ 12kW | 0,4 ~ 6kW | 0,2 ~ 6kW | 0,3 ~ 5kW |
Refrigeradores de temperatura ambiente / Refrigeradores pequenos (Desenhos personalizados)
O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.
Gama de temperaturas | -18°C ~ +30°C | Série +5°C ~ +35°C |
Capacidade de arrefecimento | 0,35 ~ 0,9kW | 1,8 ~ 50kW |
Chillers for Automotive Battery Test (Desenhos personalizados)
Simulação da temperatura para o ensaio da qualidade do veículo: ensaio da duração da bateria, banco de ensaio do injetor/motor de combustível, ensaio do airbag, banco de ensaio de componentes, etc.
Gama de temperaturas | -25°C ~ +100°C | -40°C ~ +100°C | 0°C ~ +100°C | -40°C ~ +135°C |
Capacidade de arrefecimento | 2,8 ~ 38kW | 1,2 ~ 60kW | 1,8 ~ 60kW | 4 ~ 60kW |
A temperatura / pressão / caudal podem ser controlados de forma independente.
1&2: uma máquina para controlo de dois grupos.
Gama de temperaturas | -40 ~ +100℃ 1&2 | 0 ~ +100℃ 1&2 |
Capacidade de arrefecimento | 1,8kW*2 ~ 60kW*2 | 1,8kW*2 ~ 60kW*2 |
A temperatura mantém-se constante, a pressão / caudal podem ser controlados de forma independente.
1&3: uma máquina para controlo de três grupos.
1&6: uma máquina para controlo de seis grupos.
Gama de temperaturas | -40 ~ +100℃ 1&2 | -40 ~ +100℃ 1&3 | -40 ~ +100℃ 1&6 | -20 ~ +100℃ 1&6 | 0 ~ +100℃ 1&2 | 0 ~ +100℃ 1&3 | 0 ~ +100℃ 1&6 |
Capacidade de arrefecimento | 2,5 ~ 60kW | 4 ~ 60kW | 10 ~ 60kW | 10 ~ 60kW | 7 ~ 60kW | 11 ~ 60kW | 18 ~ 60kW |
Semicondutores Refrigeradores (TES series) (Desenhos personalizados)
Adequado para o controlo preciso da temperatura de componentes electrónicos. No fabrico de componentes electrónicos de semicondutores para ambientes agressivos, as fases de montagem de embalagens IC e de ensaios de engenharia e produção incluem ensaios térmicos electrónicos e outras simulações de ensaios ambientais.
Gama de temperaturas | Série -45°C ~ +250°C | Série -85°C ~ +200°C | Série -60°C ~ +200°C |
Capacidade de arrefecimento | 0,3 ~ 25kW | 0,25 ~ 25kW | 3 ~ 60kW |
Semicondutores Refrigeradores (LTS series) (Desenhos personalizados)
Adequado para o controlo preciso da temperatura de componentes electrónicos. No fabrico de componentes electrónicos de semicondutores para ambientes agressivos, as fases de montagem de embalagens IC e de ensaios de engenharia e produção incluem ensaios térmicos electrónicos e outras simulações de ensaios ambientais.
Gama de temperaturas | Série -20°C ~ +80°C | Série -45°C ~ +80°C | Série -60°C ~ +80°C | Série -80°C ~ +80°C |
Controlo do fluxo | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Chillers para armazenamento de energia(Desenhos personalizados)
Liquid Cooling Solutions For Battery Energy Storage Systems
Gama de temperaturas | -45°C ~ +55°C |
Capacidade de arrefecimento | 45kW |
Chillers de parafuso (Desenhos personalizados)
Refrigeradores de parafuso a baixa temperatura e refrigeradores de parafuso a temperatura ambiente
Gama de temperaturas | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidade de arrefecimento | 107 ~ 1027kW (Compressor único) | 299 ~ 2134kW (Compressor duplo) | 98 ~ 934kW (Compressor único) | 272 ~ 1940kW (Compressor duplo) | 48 ~ 467kW (Compressor único) | 51 ~ 497kW (Compressor simples) |