Installation and Maintenance of Industrial Water Chiller

ClassificaçãoNotícias do sector 739

 

Installation and Maintenance of Industrial Water Chiller

 

As a industrial temperature control device, refrigerador de água industrial is often in 24-hour operation. Therefore, it is very important to choose a industrial chiller with good performance. Wuxi Guanya Refrigeration Technology Co., Ltd. specializes in the manufacturing, research, development, production and sales of industrial temperature control equipment such as refrigerador de água industrial e ultra-low temperature chiller. 15 years of concentration and experience have made LNEYA’s industrial water chiller a leader in the industry. LNEYA specializes in providing customers with cooling and heating temperature control solutions, and meets customers’ temperature needs with superior performance industrial water chiller. In order to maximize the service life of the industrial water chiller, we need to know the following installation and maintenance methods in daily use.

refrigerador de água

Installation precautions: the installation site of the industrial water chiller must be the floor or installation mat, and can bear the operating weight of the chiller. It should be placed in a machine room with a room temperature of 4.4~43.3℃, and sufficient space shall be reserved around and above the industrial water chiller for daily maintenance. When the water source and the surrounding environment of the cooling water tower are bad, the cooling water circuit must be equipped with a Y-type filter and cleaned regularly. Choose the matching cooling tower according to the refrigeration capacity of the industrial water chiller. After the chilled water piping system passes the leak test, it is necessary to wrap the insulation layer to avoid cooling loss and dripping of the pipeline.

Maintenance method: If the industrial water chiller has been used for more than 6 months, and refrigeration capacity is reduced, please arrange staff to clean the radiator. If the industrial water chiller is equipped with a pressure gauge, check whether the pressure of the high pressure gauge is higher than 300PSI. If it exceeds, please clean the radiator or check whether the water hose has been fully opened. The repair is carried out according to the above operation for several times, but the alarm signal of refrigerador de água industrial failure is still ringing, please arrange staff to repair it. After the chiller is out of service for a period of time, the water pump blade may be solidified due to the water dirt. When starting up again, the water pump rotor must be loosened first to avoid that the pump blade does not rotate and burn the motor.

Nós somos um fabricante profissional de equipamento de controlo de temperatura, apoiando serviços personalizados, por favor consulte-nos para mais pormenores!

 


Refrigeradores de água

Gama de controlo de temperatura: -150°C a +50°C

 

Ver produtos

 


Sistemas dinâmicos de controlo da temperatura

Gama de controlo de temperatura: -120°C a +350°C

 

Ver produtos

 


Refrigeradores de teste para automóveis

Gama de controlo de temperatura: -40°C a +100°C

 

Ver produtos

 


Refrigeradores de teste de semicondutores

Gama de controlo de temperatura: -85°C a +250°C

 

Ver produtos

 


Frigoríficos industriais

Gama de controlo de temperatura: -150°C a -10°C

 

Ver produtos

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água