Pesquisar Pesquisar tudo

Heater Chiller

ClassificaçãoNotícias do sector 103

Heater Chiller

 

Heater chiller is also called high and low temperature all-in-one machine, refrigeration heating temperature control system, etc. in the industry. Different manufacturers may call it differently, but the functions of this type of equipment are similar. They are routinely used in supporting reaction kettles in the pharmaceutical and chemical industries. To provide the temperature requirements for heat absorption and heat release.

First, the application introduction of heater chiller

1. The heater chiller can be equipped with reactors, reactors, extraction equipment, rotary evaporators and other instruments to increase and decrease different temperatures, and provide endothermic and exothermic reactions. Users can use explosion-proof reactors to achieve their needs. The temperature range supported by our equipment is -120°C~350°C.

2. The heater chiller can provide accurate temperature process control. It can be equipped with one reactor or multiple reactors for cooling, heating and temperature control. Using a closed circulation pipeline system, water vapor will not be absorbed during low-temperature reactions, and high-temperature reactions will not Oil mist will be generated, which can realize connection temperature rise and fall control within a certain range.

Second, precautions for heater chiller

1. Read the instruction manual before using the heater chiller, and have a certain understanding of the appearance and configuration of the equipment;

2. Turn on the power of the heater chiller, and set it according to the circuit requirements in the manual;

3. The switch of the heater chiller can be set separately and connected in parallel in the circuit to ensure that the shutdown of other equipment circuit failures will not affect the use of the equipment;

4. Check the tightness of the connecting pipeline interface between the heater chiller and supporting equipment;

5. When the heater chiller is connected to supporting equipment, care should be taken to avoid air bubbles remaining in the system, to ensure that the outlet of the heat transfer medium is connected to the lower interface of the reactor, and the inlet of the heat transfer medium is connected to the upper interface of the reactor;

6. When filling the heat transfer oil, you need to pay attention to the type of heat transfer oil. Different models have different temperature requirements. The temperature range of the heater chiller should match the temperature range of the heat transfer oil;

7. When the heater chiller is filled with heat-conducting medium, care should be taken to prevent the heat-conducting medium from overflowing to the upper cover plate, and the liquid overflowing to the upper cover plate may cause the heat-conducting medium to leak into the electrical components of the equipment, which may cause equipment failure;

8. When the temperature control effect of the equipment is not satisfactory, the user can perform system self-tuning. During the self-tuning process, the temperature will have a large overshoot, and the user should fully consider this factor before performing the system self-tuning;

9. After the heater chiller is filled with heat transfer medium and exhausted, it can start to control the temperature. After setting the temperature, press the circulation button and the refrigeration button (the circulation pump must be kept working when the equipment is running, otherwise it will cause system error). When the temperature reaches the set value, the refrigeration will be automatically turned off, and the refrigeration compressor will be turned on after the temperature rises;

Heater chiller is a kind of equipment that integrates heating, high temperature and cooling technology of cooling, heating and temperature control. During use, you need to use and maintain your product correctly, so that the equipment can be kept in good operating condition and exert high-quality temperature control effect.

 

Soluções personalizadas para o seu negócio


Sistemas de arrefecimento e aquecimento (série SUNDI)

Gama de controlo de temperatura: -120°C a +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Gama de temperaturas Série -40 ~ +200°C Série -10 ~ +200°C Série -25 ~ +200°C Série -25 ~ +300°C Série -45 ~ +250°C Série -45 ~ +300°C Série -60 ~ +250°C Série -60 ~ +300°C Série -70 ~ +250°C Série -80 ~ +250°CSérie -90 ~ +250°C Série -100 ~ +100°C -25 ~ +200°C uma máquina para dois reactores -40 ~ +200°C uma máquina para dois reactores
Capacidade de arrefecimentoaté 3kWaté 15kWaté 200kWaté 200kWaté 200kWaté 25kWaté 60kWaté 25kWaté 15kWaté 80kWaté 80kWaté 80kWaté 10*2kWaté 10*2kW

 


Sistemas de arrefecimento e aquecimento (série WTD)

(Reactores de canal micro / tubo especializados)

Gama de controlo de temperatura: -70°C a +300°C

Design especializado para micro canal (pequena capacidade de retenção de líquido, forte capacidade de troca de calor, sistema de circulação de alta queda de pressão)

 

Gama de temperaturas -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Capacidade de arrefecimentoup to 7.5kWup to 5.5kWaté 50kW

 


Cooling and Heating Systems (TES series)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Gama de temperaturas Série -45°C ~ +250°C Série -85°C ~ +200°C Série -60°C ~ +200°C
Capacidade de arrefecimentoaté 25kWaté 25kWaté 60kW

 


Cooling and Heating Machines (LTS series)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Gama de temperaturas Série -20°C ~ +80°C Série -45°C ~ +80°C Série -60°C ~ +80°C Série -80°C ~ +80°C
Controlo do fluxo7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Circuladores de arrefecimento e aquecimento

Gama de controlo de temperatura: -45°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Gama de temperaturas Série -25°C ~ +200°C Série -45°C ~ +250°C
Capacidade de arrefecimentoaté 15kWaté 15kW

 


Circuladores de aquecimento

Gama de controlo de temperatura: +50°C a +300°C

Nota: A série UC pode controlar a temperatura do meio de transferência de calor. A série UST pode não só controlar a temperatura do meio de transferência de calor, mas também controlar a temperatura do material de reação.

Gama de temperaturas +50°C ~ +200°C  (UC series) +50°C ~ +300°C (série UC) +50°C ~ +300°C (série UST)
Capacidade de aquecimentoaté 38kWaté 200kWaté 95kW

 


TCU Sistema de controlo da temperatura de multi-reactores

Gama de controlo de temperatura: -120°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Gama de temperaturas Série -45°C ~ +250°C Série -120°C ~ +250°CSistema de controlo de temperatura personalizadoRT+10°C ~ +135°C
Capacidade de aquecimentoaté 80kWaté 80kWPersonalizadoup to 300kW

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água