Heater chiller unit is a cooling and heating temperature control device that can provide cold source or heat source. It can realize cooling and heating functions during the production process to meet the temperature control requirements of different occasions.

First, the application industry of heater chiller unit

1. Pharmaceutical and chemical industry: often supporting reactors, reactors, distillation, extraction, mixing equipment, pressure vessels, drying, etc. for cooling, heating and temperature control;

2. Components industry: used to test various components, chips, and integrated circuits at different temperatures;

3. New energy industry: conduct temperature control tests at different temperatures on new energy batteries and motors.

Second, the operating instructions of the heater chiller unit

1. The heater chiller unit is used in different industries, but the temperature ranges required by different reactions are different. If a single refrigeration or heating device is used for temperature control, it will occupy more space and cost. This heater chiller unit can Manually adjust different temperature ranges to meet temperature requirements.

2. When selecting the heat conduction medium, do not use water as the heat conduction medium. Inappropriate heat conduction medium will have a negative impact on the equipment and may cause damage to the device.

3. Only use the heat transfer medium specified by the manufacturer and use it within the specified pressure range. Pay attention to its temperature limit and lower limit, combustion, viscosity, freezing point, etc., and whether it is suitable for the internal pipeline of the instrument when transferring heat. The length should be as short as possible, and the diameter should be as short as possible. If the diameter is too small, it can be limited.

4. After the heater chiller unit is filled, it is necessary to reset the equipment adjustment parameters, which is the correct operation and use required by the instrument.

5. The heat conduction medium pipeline of the heater chiller unit cannot be knotted, and the heat medium pipe should be checked regularly to avoid material strain.

6. Pay attention to the pipeline when using it. In order to avoid the pipeline, when using water-cooled equipment, please use water treatment chemicals to clean the pipeline dirt regularly when using water with high mineral content.

7. The heater chiller unit can linearly control the temperature of the material that needs to be exothermic or heated or refrigerated during the reaction process. You can choose a program to control the temperature and set the temperature of the material medium. The entire equipment is a fully closed circulation pipeline. During the temperature control process There will be no phenomenon of oil mist absorbing water, which is conducive to improving the efficiency of equipment circulation.

Different production standards of the heater chiller unit can achieve different ranges of temperature control, and the application range is greatly improved. The equipment is a commonly used temperature control equipment in the industry. It is used in pharmaceutical, chemical, biological and other industries to provide heat and cold sources for reactors, reactors, etc., and can also be used for heating and cooling of other equipment.

 

Sistemas dinâmicos de controlo de temperatura (personalização de suporte)               

 

Sistemas de arrefecimento e aquecimento (série SUNDI) (Desenhos personalizados)

Gama de controlo de temperatura: -120°C a +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Gama de temperaturas Série -10 ~ +150°C Série -25 ~ +200°C Série -25 ~ +300°C Série -45 ~ +250°C Série -45 ~ +300°C Série -60 ~ +250°C Série -60 ~ +300°C Série -70 ~ +250°C Série -80 ~ +250°CSérie -90 ~ +250°C Série -100 ~ +100°C -25 ~ +200°C uma máquina para dois reactores -40 ~ +200°C uma máquina para dois reactores
Capacidade de arrefecimento1,5 ~ 15kW1 ~ 200kW1 ~ 200kW0,45 ~ 200kW0,9 ~ 25kW0,25 ~ 60kW0,75 ~ 25kW0,4 ~ 15kW0,3 ~ 80kW0,2 ~ 80kW0,45 ~ 80kWaté 10*2kWaté 10*2kW

 


Sistemas de arrefecimento e aquecimento (série WTD) (Desenhos personalizados)

(Reactores de canal micro / tubo especializados)

Gama de controlo de temperatura: -70°C a +300°C

Design especializado para micro canal (pequena capacidade de retenção de líquido, forte capacidade de troca de calor, sistema de circulação de alta queda de pressão)

 

Gama de temperaturas -70°C ~ +300°C -45°C ~ +250°C -70°C ~ +200°C
Capacidade de arrefecimento1,1 ~ 7,5kW1,5 ~ 5,5kW11 ~ 50kW

 


Cooling and Heating Systems (TES series) (Desenhos personalizados)

Temperature Control Range: -85°C ~ +250°C

Temp Control Accuracy: ± 0.3°C

 

 

Gama de temperaturas Série -45°C ~ +250°C Série -85°C ~ +200°C Série -60°C ~ +200°C
Capacidade de arrefecimento0,3 ~ 25kW0,25 ~ 25kW3 ~ 60kW

 


Cooling and Heating Machines (LTS series) (Desenhos personalizados)

Temperature Control Range: -80°C to +80°C

It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.

 

 

Gama de temperaturas Série -20°C ~ +80°C Série -45°C ~ +80°C Série -60°C ~ +80°C Série -80°C ~ +80°C
Controlo do fluxo7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min7 ~ 45 L/min

 


Circuladores de arrefecimento e aquecimento (Desenhos personalizados)

Gama de controlo de temperatura: -45°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Gama de temperaturas Série -25°C ~ +200°C Série -45°C ~ +250°C
Capacidade de arrefecimento1 ~ 15kW0,25 ~ 15kW

 


Circuladores de aquecimento (Desenhos personalizados)

Gama de controlo de temperatura: +50°C a +300°C

Nota: A série UC pode controlar a temperatura do meio de transferência de calor. A série UST pode não só controlar a temperatura do meio de transferência de calor, mas também controlar a temperatura do material de reação.

Gama de temperaturas +50°C ~ +170°C (série UC) +50°C ~ +300°C (série UC) +50°C ~ +300°C (série UST)
Capacidade de aquecimento5,5 ~ 15kW3,5 ~ 130kW3,5 ~ 95kW

 


TCU Sistema de controlo da temperatura de multi-reactores (Desenhos personalizados)

Gama de controlo de temperatura: -120°C a +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

Gama de temperaturas Série -45°C ~ +250°C Série -120°C ~ +250°CSistema de controlo de temperatura personalizadoRT+10°C ~ +135°C
Capacidade de aquecimento25 ~ 80kW25 ~ 80kWPersonalizado25 ~ 300kW

Os direitos de autor pertencem a lneya-online.com, por favor contacte o email para mais informações: lilia@lneya.com

Ou digitalize o código QR do WhatsApp ou WeChat abaixo para nos contactar. 

WhatsAPP WeChat

digitalização

Anterior: Seguinte:
Obter um orçamento gratuito Plano

carregando...

购物车

X

我的足迹

X
palavras-chave:Alegria engarrafada refrigerador de água