Heat Pump Chiller Heater
The heat pump chiller heater is an instrument that can provide high temperature and low temperature fluid liquid temperature control. Cooling and heating are realized by one device, which can realize continuous temperature control from -80°C to 200°C, direct high temperature cooling, and achieve experimental results. temperature requirements.
First, the heating method of the heat pump chiller heater
The heat pump chiller heater is heated by heat conduction oil, circulated to the jacket layer of the reaction kettle through the circulating pump, and performs a periodic cycle in the pipeline and the jacket, and the temperature is automatically controlled to quickly reach the temperature required by the product process, using intelligent PID control Technology, can heat constant temperature can also cool down, high temperature control accuracy. The internal pipeline of the heat conduction oil heater is integrally formed of stainless steel, the heat loss in the tube is small, and the heating is uniform. The heating design of the pipeline is explosion-proof device, and the multi-point temperature control unit can be customized. Fast temperature self-control, quickly meet the temperature requirements of various products.
Second, the main application range of heat pump chiller heater
Stirring tank, reaction tank for cooling and heating temperature control
Cooling and heating temperature control in the materials testing industry
Temperature control in cooling and heating tests of new energy battery motors
Refrigeration, heating and temperature control in high and low temperature tests for chips and semiconductors in the component industry
Third, the heat conduction medium of the heat pump chiller heater
The commonly used media for heat pump chiller heaters are heat transfer oil, water, ethylene glycol, etc., depending on the temperature, the choice of heat transfer media is different.
The heat pump chiller heater adopts a closed pipeline circulation system, and the heat transfer medium circulates at high temperature and low temperature in the pipeline. Compared with the open pipeline, the closed pipeline will reduce the absorption of water vapor in the air, increase the life of the heat transfer medium, and improve cooling Heating operating efficiency.
Soluções personalizadas para o seu negócio
Sistemas de arrefecimento e aquecimento (série SUNDI)
Gama de controlo de temperatura: -120°C a +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -40 ~ +200°C | Série -10 ~ +200°C | Série -25 ~ +200°C | Série -25 ~ +300°C | Série -45 ~ +250°C | Série -45 ~ +300°C | Série -60 ~ +250°C | Série -60 ~ +300°C | Série -70 ~ +250°C | Série -80 ~ +250°C | Série -90 ~ +250°C | Série -100 ~ +100°C | -25 ~ +200°C uma máquina para dois reactores | -40 ~ +200°C uma máquina para dois reactores |
Capacidade de arrefecimento | até 3kW | até 15kW | até 200kW | até 200kW | até 200kW | até 25kW | até 60kW | até 25kW | até 15kW | até 80kW | até 80kW | até 80kW | até 10*2kW | até 10*2kW |
Sistemas de arrefecimento e aquecimento (série WTD)
(Reactores de canal micro / tubo especializados)
Gama de controlo de temperatura: -70°C a +300°C
Design especializado para micro canal (pequena capacidade de retenção de líquido, forte capacidade de troca de calor, sistema de circulação de alta queda de pressão)
Gama de temperaturas | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Capacidade de arrefecimento | up to 7.5kW | up to 5.5kW | até 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Gama de temperaturas | Série -45°C ~ +250°C | Série -85°C ~ +200°C | Série -60°C ~ +200°C |
Capacidade de arrefecimento | até 25kW | até 25kW | até 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Gama de temperaturas | Série -20°C ~ +80°C | Série -45°C ~ +80°C | Série -60°C ~ +80°C | Série -80°C ~ +80°C |
Controlo do fluxo | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Circuladores de arrefecimento e aquecimento
Gama de controlo de temperatura: -45°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -25°C ~ +200°C | Série -45°C ~ +250°C |
Capacidade de arrefecimento | até 15kW | até 15kW |
Circuladores de aquecimento
Gama de controlo de temperatura: +50°C a +300°C
Nota: A série UC pode controlar a temperatura do meio de transferência de calor. A série UST pode não só controlar a temperatura do meio de transferência de calor, mas também controlar a temperatura do material de reação.
Gama de temperaturas | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (série UC) | +50°C ~ +300°C (série UST) |
Capacidade de aquecimento | até 38kW | até 200kW | até 95kW |
TCU Sistema de controlo da temperatura de multi-reactores
Gama de controlo de temperatura: -120°C a +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Gama de temperaturas | Série -45°C ~ +250°C | Série -120°C ~ +250°C | Sistema de controlo de temperatura personalizado | RT+10°C ~ +135°C |
Capacidade de aquecimento | até 80kW | até 80kW | Personalizado | up to 300kW |