chiller 5 kw – Precision Chiller
The 5 kw chiller adopts non-start-stop refrigeration technology, combined with PID temperature control, fast cooling, and is a high-precision and high-stability cooling equipment. It provides options such as temperature, pressure, flow rate, conductivity, etc.; standard stainless steel interface, can be equipped with various specifications of joints and hoses; models with different cooling capacity, used in various laboratories and industrial production fields, to meet different requirements Cooling constant temperature requirements. What is the composition and structure of a 5 kw chiller?
2. Compressor: O compressor é o componente central de todo o sistema de refrigeração e a fonte de energia para a compressão do refrigerante. A sua função é converter a energia eléctrica de entrada em energia mecânica e comprimir o refrigerante.
2. Condenser: In the refrigeration process, the condenser plays the role of outputting heat energy and condensing the refrigerant. After the high-pressure superheated steam discharged from the refrigeration compressor enters the condenser, it transfers all the heat absorbed in the working process, including the heat absorbed from the evaporator and refrigeration compressor and in the pipeline, to the surrounding medium (water or Air) is taken away; the high-pressure superheated vapor of the refrigerant recondenses into a liquid. (According to different cooling media and cooling methods, condensers can be divided into three types: water-cooled condensers, air-cooled condensers, and evaporative condensers.) Liquid receiver: The liquid receiver is installed after the condenser, and it is connected with the condenser The discharge pipe of the device is directly connected. The refrigerant liquid in the condenser should flow into the liquid receiver unimpeded, so that the cooling area of the condenser can be fully utilized. On the other hand, when the heat load of the evaporator changes, the demand for refrigerant liquid also changes accordingly, and at that time, the liquid receiver plays the role of adjusting and storing the refrigerant. For small-scale refrigeration systems, liquid receivers are often not installed, but condensers are used to adjust and store refrigerants.
3. Dry filter: In the refrigeration cycle, moisture and dirt (oil, iron filings, copper filings) must be prevented from entering. The source of moisture is mainly the trace moisture contained in the newly added refrigerant and lubricating oil, or due to Moisture from air ingress during system servicing. If the moisture in the system is not removed, when the refrigerant passes through the throttling valve (thermal expansion valve or capillary tube), the moisture will sometimes freeze into ice due to the drop in pressure and temperature, blocking the passage and affecting the normal operation of the refrigeration device. Therefore, a dry filter must be installed in the refrigeration system.
3. Válvula de expansão térmica: A válvula de expansão térmica não é apenas uma válvula reguladora de fluxo num sistema de refrigeração de chiller pequeno, mas também uma válvula de estrangulamento no equipamento de refrigeração. É instalada entre o filtro de secagem e o evaporador no equipamento de refrigeração. A sua função O saco detetor de temperatura é enrolado à saída do evaporador. A sua principal função é estrangular e reduzir a pressão do líquido refrigerante de alta pressão e temperatura normal quando flui através da válvula de expansão térmica, e transformá-lo em vapor húmido de refrigerante de baixa temperatura e baixa pressão (principalmente líquido, uma pequena parte é vapor) no evaporador, e vaporiza no evaporador. Absorve o calor para atingir o objetivo de arrefecimento.
4. Evaporador: O evaporador é um dispositivo de permuta de calor que se baseia na evaporação (na verdade, ebulição) do líquido refrigerante para absorver o calor do meio arrefecido. A sua função no sistema de refrigeração é absorver o calor (ou produzir capacidade de arrefecimento). Para garantir que o processo de evaporação possa prosseguir de forma estável e duradoura, o gás evaporado deve ser continuamente bombeado por um compressor de refrigeração para manter uma determinada pressão de evaporação.
6. Refrigerant: Most of the 5 kw chillers used in modern industry use R22 or R12 as the refrigerant. Due to the gradual prohibition of Freon refrigerants, energy-saving and environmentally friendly R410A and pure natural hydrocarbon refrigerants will be gradually adopted . Refrigeration is the flowing working medium in the refrigerant refrigeration system. Its main function is to carry heat and realize heat absorption and heat release when the state changes.
7. Water circulation system: The water circulation system is a water pump that sends water from the water tank to the equipment that the user needs to cool. After the chilled water takes away the heat, the temperature rises, and then returns to the chilled water tank.
8. Electrical automatic control system: The electrical automatic control system includes a power supply part and an automatic control part. The power supply part supplies power to compressors, fans, water pumps, etc. through contactors. The automatic control part includes thermostat, pressure protection, delayer, relay, overload protection, etc., which are combined to achieve automatic start and stop according to water temperature, protection and other functions.
Soluções personalizadas para o seu negócio
Chillers de baixa temperatura (arrefecidos a água e a ar)
Gama de controlo de temperatura: -150°C a -5°C
Somos especializados na produção de refrigeradores de baixa temperatura com uma gama de controlo de temperatura tão baixa como -150°C, que pode satisfazer as necessidades de refrigeração de diferentes indústrias.
Gama de temperaturas | Série -25°C ~ -5°C | Série -45°C ~ -10°C | Série -60°C ~ -10°C | Série -80°C ~ -30°C | Série -110°C ~ -50°C |
Capacidade de arrefecimento | até 360kW | até 360kW | até 360kW | até 270kW | até 180kW |
Chillers de recirculação (Arrefecimento a água e ar)
Gama de controlo de temperatura: -120°C a +30°C
Nosso resfriador de recirculação adota tecnologia de refrigeração de baixa temperatura, a temperatura é tão baixa quanto -120 ℃ e vários acessórios são personalizáveis.
Gama de temperaturas | Série -25°C ~ +30°C | Série -45°C ~ +30°C | Série -60°C ~ -20°C | Série -80°C ~ -20°C | Série -120°C ~ -70°C |
Capacidade de arrefecimento | até 38kW | até 12kW | até 7,2kW | até 7,2kW | até 8,6kW |
Refrigeradores de temperatura ambiente / Refrigeradores pequenos
Gama de controlo de temperatura: +5°C a +50°C
O refrigerador pode ser amplamente utilizado em várias indústrias e laboratórios, e suporta um design personalizado.
Gama de temperaturas | -18°C ~ +30°C | Série +5°C ~ +35°C |
Capacidade de arrefecimento | até 0,9kW | até 50kW |
Equipamentos de refrigeração do tipo arrefecimento direto
Gama de controlo de temperatura: -120°C a -10°C
É adequado para locais com pequena área de troca de calor e grande troca de calor.
Gama de temperaturas | -40°C ~ -10°C | -80°C ~ -35°C | -120°C ~ -90°C |
Potência do compressor | até 8HP | até 8HP*2 | até 45HP*3 |
Chillers de arrefecimento direto de temperatura ultra baixa
Gama de controlo de temperatura: -150°C a -110°C
Soluções personalizadas para a sua empresa.
Gama de temperaturas | -150°C ~ -110°C |
Capacidade de arrefecimento | até 11kW |
Chillers de parafuso
Refrigeradores de parafuso a baixa temperatura e refrigeradores de parafuso a temperatura ambiente
Soluções personalizadas para a sua empresa.
Gama de temperaturas | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | +5°C ~ +30°C | -25°C ~ +5°C | -25°C ~ +5°C |
Capacidade de arrefecimento | até 1027kW (Compressor único) | até 2134kW (Compressor duplo) | até 934kW (compressor único) | até 1940kW (Compressor duplo) | até 467kW (Compressor único) | até 497kW (Compressor único) |