Recirculating Chiller Air Cooled

분류업계 뉴스 169

Recirculating Chiller Air Cooled

 

The definition of recirculating chiller air cooled: low-temperature cooling liquid circulation pump adopts the circulation pump equipment of compression refrigeration method, which can directly cool test tubes, reaction bottles, etc. to carry out chemical reactions at low temperature, and carry out low-temperature storage of chemicals and biological products, and can also be combined with rotary evaporation Apparatus, vacuum freeze-drying oven, circulating water multi-purpose vacuum pump, etc. Recirculating chiller air cooled adopts air-cooled hermetic compressor unit refrigeration and microcomputer intelligent control system to provide low-temperature circulating cooling water (liquid) flow or low-temperature constant-temperature water (liquid) flow to meet cooling or constant-temperature instruments with cooling water and low-temperature liquid , Such as rotary evaporators, fermentation tanks, electron microscopes, low-temperature chemical reactors, electron energy spectrometers, mass spectrometers, density meters, freeze dryers, vacuum coating instruments, reactors, etc. Various volumes can also be directly tested at low temperature and constant temperature in the tank.

Advantages of recirculating chiller air cooled:

1. The large-capacity open bath and the external circulation are integrated, which can be used as a freezing tank and provide cooling liquid to the outside.

2. The digital setting and display of the recirculating chiller air cooled temperature is easy to operate.

3. Key components such as the refrigeration compressor of the recirculating chiller air cooled are imported from international brands with high reliability.

4. The circulation system of recirculating chiller air cooled is made of polymer anti-corrosion material, which can prevent rust, corrosion and low-temperature liquid pollution.

Precautions for using recirculating chiller air cooled:

1. Liquid medium should be added to the tank before use. The liquid medium generally uses more than 95% alcohol, and the liquid medium should not be lower than 20mm of the worktable.

2. The recirculating chiller air cooled should be placed in a dry and ventilated place, and the back and sides should be 400mm away from obstacles.

3. The working power supply should be determined according to the model of the machine. The power of the power supply should be greater than or equal to the total power of the instrument. The power supply must have a good “grounding” device.

4. After use, all switches must be turned off before unplugging the power plug.

Instructions for use of recirculating chiller air cooled:

1. Before use, the liquid inlet and outlet valves must be installed on the liquid inlet. Note: The liquid inlet and outlet are marked on the top of the machine, the valve is a stop valve, the valve medium flows in a direction, the valve is marked with the flow direction, and the oil level gauge has an observation window.

2. Connect the external circulation equipment such as the valve and the reactor with hoses. The inlet and outlet of the reactor should be bottom-in and top-out, and the medium in the reactor should be kept in a proper position.

3. Open the liquid filling hole of the low temperature tank, add the refrigerant into the cold tank, turn on the cycle switch of the machine, and let the liquid circulate in the whole system.

 

비즈니스를 위한 맞춤형 솔루션


 

저온 냉각기

저온 냉각기(수냉식 및 공냉식)

온도 제어 범위: -150°C ~ -5°C

당사는 -150°C의 낮은 온도 제어 범위를 갖춘 저온 냉각기 생산을 전문으로 하며, 다양한 산업의 냉장 요구 사항을 충족할 수 있습니다.

온도 범위 -25°C ~ -5°C 시리즈 -45°C ~ -10°C 시리즈 -60°C ~ -10°C 시리즈 -80°C ~ -30°C 시리즈 -110°C ~ -50°C 시리즈
냉각 용량최대 360kW최대 360kW최대 360kW최대 270kW최대 180kW

 


재순환 냉각기

재순환 냉각기 (수냉식 및 공냉식)

온도 제어 범위: -120°C ~ +30°C

당사의 재순환 냉각기는 저온 냉동 기술을 채택하고 온도가 -120℃까지 낮으며 다양한 액세서리를 사용자 정의 할 수 있습니다.

온도 범위 -25°C ~ +30°C 시리즈 -45°C ~ +30°C 시리즈 -60°C ~ -20°C 시리즈 -80°C ~ -20°C 시리즈 -120°C ~ -70°C 시리즈
냉각 용량최대 38kW최대 12kW최대 7.2kW최대 7.2kW최대 8.6kW

 


물 냉각기

실온 냉각기/소형 냉각기

온도 제어 범위: +5°C ~ +50°C

이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.

온도 범위 -18°C ~ +30°C +5°C ~ +35°C 시리즈
냉각 용량최대 0.9kW최대 50kW

 


직접 냉각 기계

 

직접 냉각식 냉동 장비

온도 제어 범위: -120°C ~ -10°C

열 교환 면적이 작고 열 교환이 큰 장소에 적합합니다.

 

온도 범위 -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
압축기 전력최대 8HP최대 8HP*2최대 45HP*3

 


 

직접 냉각식 초저온 냉각기

온도 제어 범위: -150°C ~ -110°C

비즈니스를 위한 맞춤형 솔루션.

 

온도 범위 -150°C ~ -110°C
냉각 용량최대 11kW

 


스크류 냉각기

 

스크류 냉각기

저온 스크류 냉각기 및 실온 스크류 냉각기

비즈니스를 위한 맞춤형 솔루션.

 

 

온도 범위 +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
냉각 용량최대 1027kW(단일 컴프레서)최대 2134kW(듀얼 컴프레서)최대 934kW(단일 컴프레서)최대 1940kW(듀얼 컴프레서)최대 467kW(단일 컴프레서)최대 497kW(단일 컴프레서)

 