It is difficult for industrial chillers to be the same as the rated conditions in actual operation, and there is a certain difference between the maximum cooling capacity of the equipment and the cooling performance coefficient. Therefore, users should properly maintain the cold water outlet temperature, cooling water inlet temperature, cooling water, and fouling coefficient of cold water pipes of the chiller under different loads. When the cold water outlet temperature of the chiller is increased by 1°C or the cooling water inlet temperature is decreased by 1°C, the cooling performance coefficient will increase by 2% to 3%. The following LNEYA will introduce the three major factors that affect the refrigeration performance coefficient of industrial chillers:

1. Cooling water outlet temperature

With the increase of the water temperature of the chiller, the cooling capacity and the cooling performance coefficient of the chiller are improved. When the cold water outlet temperature is increased from 6℃ to 10℃, the cooling capacity is increased by 13%, and the cooling performance coefficient is increased by 11%.

2. Cooling water inlet temperature

As the cooling water inlet temperature decreases, the cooling capacity and performance coefficient of the chiller increase. When the cooling water inlet temperature is reduced from 32°C to 26°C, both the cooling capacity and the cooling coefficient of performance are increased by about 20%.

3. Fouling coefficient

Affected by water quality, the heat exchanger of the chiller will be fouled. With the extension of the operating time of the chiller, the fouling phenomenon will become more serious, the fouling coefficient will increase, the heat exchange capacity of the heat exchanger will decrease, and the refrigeration of the equipment will be reduced. The capacity and cooling coefficient of performance will also decrease accordingly.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


저온 냉각기

워터 칠러

온도 제어 범위: -150°C ~ +50°C

 

 


냉난방 시스템

동적 온도 제어 시스템

온도 제어 범위: -120°C ~ +350°C

 

 

 


배터리 냉각 시스템

자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

 

 


반도체 테스트 냉각기

반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

 

 


산업용 냉동고

산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
무료 견적 요금제 받기

로딩 중...

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기