An important indicator module in the installation and maintenance of the screw chiller is the installation of the expansion valve of the screw chiller. Next, I will introduce the relevant aspects.

First of all, the installation position of the expansion valve of the screw chiller should be as close to the evaporator as possible, so that the low-temperature refrigerant after throttling will immediately enter the evaporator to absorb heat or cool, and the convenience of its adjustment and repair should also be considered. When the expansion valve supplies liquid to the coil, a distributor should be installed behind the valve to ensure the uniformity of liquid supply to each evaporation coil. If the resistance of the distributor is large, an external balance thermal expansion valve should be installed. A filter or filter dryer should be installed on the expansion valve to remove the garbage or moisture in the system to prevent the expansion valve from being blocked and affecting the normal circulation of the refrigerant.

Secondly, the installation of the temperature sensor package. The temperature felt by the temperature sensor will directly affect the opening of the expansion valve. The temperature sensor should be installed on the suction pipe at the outlet of the hair dryer. If the suction pipe is equipped with a liquid-gas regenerator or heat exchanger. Then the temperature sensor package should be installed on the suction pipe flowing out of the regenerator. The contact part of the temperature sensing package and the suction pipe should be straight and clean, and the two have good heat transfer. The temperature sensing package and the suction pipe should be fastened with straps, and a non-moisture-absorbing thermal insulation material should be added for heat insulation. The temperature sensing package should be installed on the suction pipe that is not easy to accumulate liquid. When the diameter of the suction pipe is less than 21mm, the temperature sensing package should be placed on the upper part of the suction pipe. When the diameter is larger than the above diameter, the temperature sensing package should be installed on the horizontal axis of the suction pipe. The lower part is about 45.1°.

Finally, the installation of the outer balance pipe. The outer balance pipe should be installed at the outlet of the evaporator, and should be behind the temperature sensing bulb. The two positions cannot be interchanged, because a very small amount of refrigerant liquid inside the expansion valve may leak into the outer balance pipe and reach the suction pipe. , If the temperature sensor package is behind the interface, the temperature received by the temperature sensor package is low, and the opening of the expansion valve is insufficient, which affects the normal operation of the refrigeration device.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


저온 냉각기

워터 칠러

온도 제어 범위: -150°C ~ +50°C

 


냉난방 시스템

동적 온도 제어 시스템

온도 제어 범위: -120°C ~ +350°C

 

 


배터리 냉각 시스템

자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

 


반도체 테스트 냉각기

반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

 


산업용 냉동고

산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
무료 견적 요금제 받기

로딩 중...

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기