Causes and Solutions of Water Leakage of Chiller

분류업계 뉴스 324

Causes and Solutions of Water Leakage of Chiller

 

The prerequisite for the normal operation of the chiller is that the water cycle, refrigerant cycle, and electronic control system are all kept normal. If there is a problem on the one hand, then the chiller will be abnormal and affect the production of the factory. If the water chiller leaks, it usually occurs in the water pipe and the water pipe connection.

The water circulation system of the chiller is composed of water inlet pipes, evaporators, water outlet pipes, water tanks, chilled water pumps, cooling water pumps, condensers, pipes and valves at various connections, and the above-mentioned parts are basically indispensable for water leakage failures.

1. Water leakage at the water inlet and outlet of the chiller is usually caused by loose or broken bolts at the joint, which can be repaired or replaced;

2. The evaporator shell of the chiller is leaking. Check whether there is water seepage at the welding part of the evaporator shell. If so, repair it by welding as soon as possible;

3. There is water leakage at the float valve of the water chiller, and the float valve controls the water inlet valve switch according to the buoyancy. The solution: check and adjust the position of the ball valve, and replace and repair it in time if it is damaged.

4. Water leakage occurs due to the perforation of the condenser inside the chiller. The solution: find the fault point and repair it;

5. The water tank of the chiller is too full to cause water leakage due to the fluctuation of the cooling water during operation. The solution: reduce the water level in the water tank;

6. The water tank of the chiller is leaking, which may be due to the corrosion of the welding position of the water tank, causing leakage, and re-welding maintenance is required;

7. Water leakage occurs at the water pump of the chiller. Generally, the shaft seal at the water pump is not well connected or damaged. Just replace the shaft seal of the water pump;

8. Long-term tilting of the chiller will cause uneven force on the valves and pipes of the chiller, damage, and water leakage. The chiller should be placed horizontally according to the specifications. If the chiller leaks slightly, follow the water traces to find the leak point of the unit. If the chiller leaks in the water cooling system, it will cause insufficient water flow, compressor high-pressure alarm and other failures. Water accumulated at the bottom will corrode the casing of the unit and cause potential safety hazards to the electrical components of the unit. Therefore, once the water leakage of the chiller is found, it should be paid attention to and repaired in time.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


워터 칠러

온도 제어 범위: -150°C ~ +50°C

 

제품 보기

 


동적 온도 제어 시스템

온도 제어 범위: -120°C ~ +350°C

 

제품 보기

 


자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

제품 보기

 


반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

제품 보기

 


산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

 

제품 보기

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
무료 견적 요금제 받기

로딩 중...

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기