검색 모두 검색

Advantages of Parallel Chillers

분류업계 뉴스 192

Advantages of Parallel Chillers

 

1. According to the number of equipment turned on and the cooling capacity required by the equipment, the number of compressors to be turned on is automatically selected, which greatly saves energy, and saves more than 20% of electricity compared with units of the same power.

2. Compact structure: compressors, accumulators, gas-liquid separators, etc., including electronic control equipment, are all centralized together, with a highly integrated design concept.

3. If one mainframe fails, other mainframes can still supply cooling intermittently to reduce losses.

4. Automatically select the host with short cumulative working time to boot first each time it is turned on, to ensure that all the hosts have the same working time, and can avoid frequent startup of individual hosts through fuzzy control, greatly extending the service life of the host.

5. The PLC control has high stability, ensuring that there will be no failure in electrical control during long-term operation.

6. PLC control can truly realize that the refrigeration system does not require professional management, and can realize remote temporary control, which can temporarily control the working conditions of any equipment at any time in the main engine room.

7. The color touch screen man-machine interface allows users to set the working parameters of each device and the host more easily.

8. The PLC control has high stability, ensuring that there will be no failures in electrical control during long-term operation.

9. Equipped with phase loss, phase sequence, voltage, oil pressure, liquid level, high voltage, low voltage, motor overload, protection module, oil flow protection, air circuit breaker protection and other protections, and automatically handle alarms according to the protection level, if necessary Intervention staff.

10. PLC control can truly realize that the refrigeration system does not require professionals to manage it. It can be realized that the operation of any equipment can be controlled at any time in the main engine room, and it can also be remotely inspected, modified, and remotely Fault diagnosis and processing of high reliability unit design.

11. Low maintenance, fully automatic control, to ensure that the equipment is carried out under good working conditions and to give full play to the high performance of the equipment.

12. Quick response. The entire control system adopts closed-loop control, the temperature can be maintained in the set range, and fuzzy control is adopted to automatically adjust the speed of compressor startup and shutdown according to the actual situation, saving customers more time for production.

13. The PLC can display the basic information of the unit operation, as follows:

a. Compressor suction and discharge pressure, temperature; oil temperature, oil pressure difference

b. The current and voltage of the main motor

c. Compressor loading and unloading percentage

d. External start/stop command status; compressor starter status

e. Basic automatic protection function of the unit

f. Overcurrent

g. Compressor starter failure, compressor running failure, general failure, sensor failure.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


저온 냉각기

워터 칠러

온도 제어 범위: -150°C ~ +50°C

 


냉난방 시스템

동적 온도 제어 시스템

온도 제어 범위: -120°C ~ +350°C

 

 


배터리 냉각 시스템

자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

 


반도체 테스트 냉각기

반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

 


산업용 냉동고

산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
무료 견적 요금제 받기

로딩 중...

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기