The Reasons for the Slow Cooling Speed of the Chiller

ClassificationNouvelles de l'industrie 367

The Reasons for the Slow Cooling Speed of the Chiller

 

At present, in industrial production, chillers are indispensable temperature control equipment, and each equipment is inseparable from the participation of refrigerants in operation. Therefore, insufficient cooling capacity will affect the normal operation of the machine. If there is a problem with the device, it will bring a lot of trouble to the user. So when we encounter the problem of insufficient cooling capacity of the chiller or too slow cooling speed, how to solve it?

1. Check for the presence of air in the industrial chilled mechanical cooling system. When the chiller is installed, there can be no air, not even a little bit, of air, whether inside, pump or pipe. In addition, there is a film inside the pump, remember to tear it all off before installation. Otherwise, the water cannot circulate or circulate very slowly, which directly affects the operation of the chiller.

2. The occurrence of this situation is also closely related to the loss of cooling capacity. Insufficient insulation thickness of equipment and pipelines or damage to the insulation layer, resulting in increased cooling loss and affecting the cooling effect. When the user is operating, once the outer surface of the insulation layer is found to be wet or frosted, it means that the thickness of the insulation layer is insufficient, and the insulation layer should be replaced in time. In addition, the cover of the evaporator water tank is not tight, the sealing door of the air-conditioning treatment room or the air-conditioning storage room is damaged, and the air supply duct and the doors and windows of the air-conditioning storage room are leaking. This will lead to increased cooling loss, and enterprises should take timely countermeasures.

3. The low efficiency of refrigeration compressors is also a reason. Long-term operation of equipment, wear and tear of moving parts, increase in matching clearance or poor sealing will lead to a decrease in the actual air delivery capacity of the compressor and a decrease in cooling capacity. At this point, the refrigeration compressor needs to be checked. If it cannot be repaired, it should be replaced in time. The presence of air in the system can also cause this situation. At this time, the exhaust pressure is high, the temperature is high, the power consumption is large, and the cooling capacity is reduced.

4. When each chiller is installed, the evaporator and pipelines should be wrapped with thermal insulation cotton to prevent the loss of cooling capacity. If the cooling speed of the unit is slow, the enterprise should first check whether the thickness of the insulation layer of the pipeline is insufficient, or whether the insulation layer is damaged. Remember to wrap it in thermal insulation and make sure it’s thick enough.

The reasons for insufficient cooling capacity or slow cooling speed of industrial cooling water units are shared here. If this phenomenon occurs in industrial cooling water units, the above reasons are generally inseparable. Of course, if the problem cannot be solved after following the methods analyzed above, it is recommended that you directly contact the chiller manufacturer for inspection and maintenance, so as to avoid a wider range of failures.

Nous sommes un fabricant professionnel d'équipements de contrôle de la température et nous offrons des services personnalisés. nous consulter pour plus de détails !

 


refroidisseur d'eau à basse température

Refroidisseurs d'eau

Plage de contrôle de la température : -150°C à +50°C

 


système de refroidissement et de chauffage

Systèmes de contrôle dynamique de la température

Plage de contrôle de la température : -120°C à +350°C

 

 


système de refroidissement de la batterie

Refroidisseurs pour essais automobiles

Plage de contrôle de la température : -40°C à +100°C

 

 


refroidisseur pour tests de semi-conducteurs

Refroidisseurs pour essais de semi-conducteurs

Plage de contrôle de la température : -85°C à +250°C

 

 


congélateur industriel

Réfrigérateurs industriels

Plage de contrôle de la température : -150°C à -10°C

Les informations sur les droits d'auteur appartiennent à lneya-online.com, veuillez contacter l'e-mail pour plus de détails : lilia@lneya.com

Ou scannez le code QR WhatsApp ou WeChat ci-dessous pour nous contacter. 

WhatsAPP WeChat

scanner

Précédent : Suivant :
Obtenir un devis gratuit Plan

chargement...

购物车

X

我的足迹

X
mots-clés:La joie en bouteille refroidisseur d'eau