Recherche Rechercher tous

Stand Alone Chiller System for Process Chilled Water

ClassificationNouvelles de l'industrie 389

Stand Alone Chiller System for Process Chilled Water

 

A chiller is a cooling device that can provide constant temperature, constant flow, and constant pressure. It can also be called a constant temperature chiller. The principle of the chiller is to inject a certain amount of water into the internal water tank of the machine, cool the water through the chiller refrigeration system, and then the water pump inside the machine injects low-temperature frozen water into the equipment that needs to be cooled, and the chilled water transfers the heat inside the machine Take it away, and return the high-temperature hot water to the water tank again to cool down, so that the cooling is circulated and exchanged to achieve the effect of cooling the equipment.

◆Excellent performance

1. The main engine adopts the international advanced semi-hermetic screw rotor compressor, and the motor and compressor adopt an integrated design without shaft seal leakage, which is 20%-30% higher in energy efficiency than ordinary compressors;

2. Two compressors or multiple compressors have a start-up and stop cycle control program, which can balance the load and prolong the service life of the unit;

3. Two compressors or more units adopt multiple refrigeration circuits. When one of the circuits needs to be repaired and maintained, the other circuits can still operate normally and have a backup function;

4. The compressor is started by unloading and step-down to avoid impact on the power grid.

5. The chilled water outlet temperature of the chiller can be controlled above 5°C;

6. The unit can be equipped with an environmentally friendly and energy-saving heat recovery device as needed, which can produce free hot water during cooling.

◆Easy to install

1. The chiller unit has a compact structure and a small footprint, saving space in the machine room;

2. When the whole machine leaves the factory, it has been strictly debugged and fixed to complete, and it has fully reached the design state;

3. The vibration of the unit is very little, the foundation does not need special vibration isolation measures, and the installation is simple;

4. Only need to connect the evaporator chilled water and condenser cooling water pipes during installation.

5. The chiller unit can carry out intelligent program control according to the load change: 100%, 75%, 50%, 25% (or start), 0, saving energy consumption;

◆Complete security protection functions

1. Pressure protection: high-pressure and low-pressure automatic protection device for the refrigeration system of the chiller;

2. Power supply protection: undervoltage protection, phase loss protection, reverse phase protection, overload protection, motor overheat protection;

3. Antifreeze protection: when the chilled water temperature is too low, the unit will automatically stop;

4. Safety valve protection: When the refrigerant pressure exceeds a certain value, the safety exhaust valve will automatically open;

5. Delay protection: Delay start protection of the chiller compressor to prevent the compressor from starting frequently;

6. Water flow protection: When the water flow stops or drops, continuing to run will endanger the equipment, and the equipment will automatically shut down.

 


refroidisseur à basse température

Refroidisseurs basse température (refroidis par eau et par air)

Plage de contrôle de la température : -150°C à -5°C

Application : Réacteurs divers, systèmes de distillation ou d'extraction, laboratoires, instituts de recherche, industries chimique, pharmaceutique, pétrochimique, biochimique, médicale, hospitalière, ateliers de R&D, tests de semi-conducteurs, aérospatiale, biologique et autres.

Plage de température Série -25°C ~ -5°C Série -45°C ~ -10°C Série -60°C ~ -10°C Série -80°C ~ -30°C Série -110°C ~ -50°C
Capacité de refroidissementjusqu'à 360 kWjusqu'à 360 kWjusqu'à 360 kWjusqu'à 270 kWjusqu'à 180 kW

 


refroidisseur à recirculation

Circulateurs réfrigérés (Refroidissement par eau et par air)

Plage de contrôle de la température : -120°C à +30°C

Application : Réacteurs divers, systèmes de distillation ou d'extraction, laboratoires, instituts de recherche, industries chimique, pharmaceutique, pétrochimique, biochimique, médicale, hospitalière, ateliers de R&D, tests de semi-conducteurs, aérospatiale, biologique et autres.

Plage de température Série -25°C ~ +30°C Série -45°C ~ +30°C Série -60°C ~ -20°C Série -80°C ~ -20°C Série -120°C ~ -70°C
Capacité de refroidissementjusqu'à 38 kWjusqu'à 12 kWjusqu'à 7,2 kWjusqu'à 7,2 kWjusqu'à 8,6 kW

 


refroidisseur d'eau

Refroidisseurs à température ambiante / Petits refroidisseurs

Plage de contrôle de la température : +5°C à +50°C

Application : Réacteurs divers, systèmes de distillation ou d'extraction, laboratoires, instituts de recherche, industries chimique, pharmaceutique, pétrochimique, biochimique, médicale, hospitalière, ateliers de R&D, tests de semi-conducteurs, aérospatiale, biologique et autres.

Plage de température -18°C ~ +30°C Série +5°C ~ +35°C
Capacité de refroidissementjusqu'à 0,9 kWjusqu'à 50 kW

 

Les informations sur les droits d'auteur appartiennent à lneya-online.com, veuillez contacter l'e-mail pour plus de détails : lilia@lneya.com

Ou scannez le code QR WhatsApp ou WeChat ci-dessous pour nous contacter. 

WhatsAPP WeChat

scanner

Précédent : Suivant :
Obtenir un devis gratuit Plan

chargement...

购物车

X

我的足迹

X
mots-clés:La joie en bouteille refroidisseur d'eau