Search Search all

Data Center Cooling System Types

ClassificationIndustry News 109 0

Data Center Cooling System Types

Contact us today for the perfect temperature control solution

 

From the perspective of cooling methods, there are two main cooling methods for data center computer rooms: air cooling and liquid cooling. The cooling capacity of liquid cooling is 1,000 to 3,000 times that of air, and liquid cooling has low environmental requirements and strong adaptability. Liquid cooling is mainly divided into immersion liquid cooling and cold plate liquid cooling. In addition, what other cooling methods are used in the data center computer room?

1. The first type is traditional water-cooled or air-cooled chiller refrigeration. Air cooling, water cooling, air-liquid hybrid and cold plate liquid cooling solutions are very mature, and the immersed solution is more efficient, green and energy-saving.

The increase in chip computing power has brought about an increase in the difficulty of heat dissipation for a single chip. As the upper limit of air cooling solution capabilities approaches, it will be difficult to solve the heat dissipation problem with air cooling alone in the future.

The deployment cost of immersed liquid cooling is high, several times that of traditional data center cooling modes. It is currently mainly used in intelligent computing centers or ultra-large data centers of leading customers. In the next two to three years, it is expected to gradually be implemented in the Internet, telecommunications, finance, and manufacturing industries. Large-scale development will also go through a long process.

 

Data Center Cooling System Types

 

2. The second type is natural cooling source combined with traditional refrigeration system. This system is generally suitable for cold areas and has absolute advantages in meeting the temperature environment requirements of data center rooms.

3. The third type is fluorinated liquid immersion refrigeration. Using the 50°C boiling point characteristics of fluorinated liquid, phase change refrigeration is used to cool the CPU, and then condensation, liquefaction and reflux are used. The current test results are good. The advantage of this method is that the unit heat flux density of the phase change of the fluorinated liquid is large, which can satisfy the fan heating of the CPU with high heat flux density. In addition, some units use fluorinated liquid as a cooling system, which circulates and cools the fluorinated liquid on the basis of soaking. The heat exchange is between convection and supercooled boiling, and the heat transfer efficiency is also high. This solution requires a large amount of fluorinated liquid and the initial investment cost is high.

4. The fourth type is evaporative refrigeration. This system mainly absorbs heat and refrigeration through the evaporation of water vapor, without the need for compressor compression. The electricity load of the system is low, and the PUE can reach 1.1. However, this solution is greatly affected by the weather and is more suitable for places with low humidity and temperature, which is affected by geographical location. In addition, the refrigeration equipment is larger and requires higher investment.

5. The fifth type is absorption refrigeration. This method mainly uses waste heat for cooling, but the temperature of the heat source has a great influence on the cooling efficiency. The heat source recovered in the data center is at 50°C, so the efficiency of absorption refrigeration is very low and technically difficult. If there is a waste heat source with a higher temperature of 90℃ or above near the data center, this method is more energy-saving. This type of refrigeration solution is currently rarely used, and most scientific research institutions are still exploring absorbing materials and reducing the temperature of the recovered heat source.

6. The sixth method is to use direct cooling system for refrigeration. Freon is currently subject to restrictions due to its double carbon. The transcritical cycle or supercritical cycle of carbon dioxide can be used, but more scholars need to apply and develop it.

 

ModelZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Temp range +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Cooling water5℃~30℃ Adopt Siemens/Honeywell regulating valve to control cooling water flow
Temperature control accuracy±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
flow control10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
The flow control is adjusted by frequency converter, the accuracy is ±0.3L/min
Cooling capacity (MAX)15kW25kW50kW75kW100kW150kW
Storage volume15L30L60L100L150L200L
BrineWater, silicone oil, fluorinated liquid, ethylene glycol aqueous solution, etc.
Medium pipelineSUS304SUS304SUS304SUS304SUS304SUS304
In and out interface sizeG3/4G1G1DN32DN40DN50
Cooling water interfaceG3/4G1DN40DN50DN50DN65
Cooling water flow 7~20℃2.5m³/h4m³/h8m³/h13m³/h17m³/h25m³/h
380V 50HZ 1kW1.5kW3kW4kW5kW6kW
shellCold-rolled sheet spray RAL7035

 

ModelZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Temp range +5℃~35℃
Temp accuracy±0.5℃
Flow control15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Cooling capacity(MAX) 200kW250kW300kW400kW500kW
Storage volume250L300L600L1000L1200L
MediumWater, silicone oil, fluorinated liquid, ethylene glycol aqueous solution, etc.
Medium pipelineSUS304
In and out interface sizeDN65DN65DN65DN80DN80
Cooling water interfaceDN80DN80DN100DN100DN125
Cooling water flow 7~20℃34m³/h43m³/h51m³/h69m³/h86m³/h
Power supply 380V 50HZ7kW7kW8kW9kW13kW
shellCold-rolled sheet spray RAL7035

 

cooling distribution unit

 

We provide complete temperature control system design and manufacturing. From standard models to complete customized products up to 1000 tons. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.

We provide non-standard customized solutions. 

 

Email: lilia@lneya.com   WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 

scan

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Request a Quote
Call
Mailbox
Name
Company
Please fill in your product requirements
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller