Search Search all

25 Ton Chiller

ClassificationIndustry News 202

25 Ton Chiller

 

The 25 ton chiller has been widely used in various industries that are becoming more and more familiar. Its main function is to provide industrial chilled water to equipment and products. The water temperature requirement can be adjusted according to the user’s requirements, but its accuracy can be more accurately controlled at ±0.5°C. However, during the operation of the unit, some users may encounter the situation that the temperature cannot drop, let us analyze the reason together!

There are mainly the following reasons:

1. As far as our 25 ton chiller is concerned, all the machines have been 100% performance tested before leaving the factory to ensure the normal operation of the machine. If this problem occurs during the initial use, it may be that the 25 ton chiller is not matched correctly.

2. When the 25 ton chiller is used for the first time, another reason why the temperature does not drop is that there are some problems with the installation of the cooling tower, circulation pump and piping of the equipment, which need to be carefully checked according to the installation diagram;

3. If this happens to the 25 ton chiller that has been used for more than half a year or one year, it may be the following problems:

a. The heat exchanger of the 25 ton chiller is too dirty. It is recommended to clean the heat exchanger and clean it regularly during subsequent use;

b. The refrigeration system of the 25 ton chiller is leaking Freon. It is recommended to find out the leak point, repair the welding, and add refrigerant;

c. It may be that the working temperature of the 25 ton chiller is relatively extreme, too high or too low, causing the industrial chiller to fail to meet the requirements. In this case, only a larger industrial chiller can be selected to meet the working requirements.

4. It may be that the water source used has impurities, which have been accumulated for a long time and attached to the pipes between the various devices, resulting in a small water flow. Therefore, it is necessary to clean the pipelines between the various equipment.

In the process of using the 25 ton chiller, the customer needs to find professional maintenance personnel to repair and deal with it. For users with poor water sources, the user needs to perform the following professional treatment, and maintain the water-cooled chiller at regular intervals.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller