Please Search Dynamic temp. control systems Ultra-Low Temp. Chillers NEV Test Chillers Thermal Test & Process Cooling TCU Unit

SR  -120°C ~ +250°C

SR -120°C ~ +250°C

  • Temperature Control Range: -120°C ~ +250 °C
  • Temperature Control Accuracy: ±1 °C
  • MODBUS RTU Protocol, RS485 Interface, Optional Ethernet Interface/R232 Interface

Note: Both Air Cooled And Water Cooled Are Available. Explosion Proof Cabinet Can Be Customized.

 

Application: Various Reactors, Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Biological and Other Industries.

 

Request a Quote          Email Us           More Product Models

Product Description

Excellent performance, high precision, intelligent temperature control, very wide temperature control range, from -120 °C ~ 350 °C, suitable for most enterprises temperature control needs. Product temperature control accuracy of ± 0.5 ° C, cooling power from 0.5 kW to 1200 kW can provide the corresponding products.

Temperature Process Control Principle

Through three-point sampling (material temperature point, temperature control system outlet temperature, temperature control system inlet temperature), and our own model-free self-built tree algorithm and general anti-lag cascade algorithm, solve the problem of large delay in pharmaceutical chemical temperature control.

Features:

  • Users can get a closed and repeatable temperature control in a wide temperature range, which can realize temperature control of - 120 ~ 300 ℃.
  • The built-in electric heating heat transfer oil auxiliary system can automatically start the auxiliary heating system according to the demand to reduce the steam pressure.
  • It can accurately match the heat demand through rapid operation to achieve the purpose of energy conservation.
  • The temperature of the whole reaction process is controlled by fast calculation, and the exothermic and endothermic reactions in the whole reaction process are controlled by fast response.
  • A standardized interface is reserved, and the cold and heat source heat exchange module can be added according to the actual demand.
  • The reaction process temperature and single fluid temperature can be selectively controlled, and the temperature difference between the reaction process temperature and single fluid temperature can be set and controlled.
  • Fully enclosed pipeline design is adopted.
  • To ensure the safe operation of the system, the electric valves can be fully opened manually.

Model SR-35N
SR-35NS
SR-35NH
SR-35NSH
SR-50N
SR-50NS
SR-50NH
SR-50NSH
SR-80N
SR-80NS
SR-80NH
SR-80NSH
SR-125N
SR-125NS
SR-125NH
SR-125NSH
SR-200N
SR-200NS
SR-200NH
SR-200NSH
Temp. range ℃ -120~ 250degree setting the max temp according to the supplier heating or cooling source)
-40~135degree(The maximum temperature range can be operated by using glycol water formula.)
SR-N A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank.
SR-NS Besides SR- N function,add one set heater used to reduce high temp.
SR-NH Besides SR- N  function,add electrical heating function
SR-NSH Besides SR- N  function,add one set heater used to reduce high temp and electrical heating function
Expansion tank 100L 200L 280L 390L 500L
Heat exchanger area 3.5m2 5m2 8m2 12.5m2 20m2
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temperature control selection Material control temp
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Material temp. feedback:PT100 or 4~20mA or communication given
Temp.feedback:PT100
Process temp. feedback
feedback:PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 200L/min 2.5BAR 250L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension mm 1000*1200*1750 1250*1250*2000 1500*1500*2050 2050*1450*2050 2050*1450*2050
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material SUS 304 SUS 304 SUS 304 SUS 304 SUS304
Model SR-35N
SR-35NS
SR-35NH
SR-35NSH
SR-50N
SR-50NS
SR-50NH
SR-50NSH
SR-80N
SR-80NS
SR-80NH
SR-80NSH
SR-125N
SR-125NS
SR-125NH
SR-125NSH
SR-200N
SR-200NS
SR-200NH
SR-200NSH
Temp. range ℃ -120~ 250degree setting the max temp according to the supplier heating or cooling source)
-40~135degree(The maximum temperature range can be operated by using glycol water formula.)
SR-N A set of cooling heat exchanger, heat exchanger, through proportional adjusting valve control cold heat into the heat exchanger, then through the uniform medium input to the reactor jacketed to do heat exchange and temp. Control, system has inside expansion tank.
SR-NS Besides SR- N function,add one set heater used to reduce high temp.
SR-NH Besides SR- N  function,add electrical heating function
SR-NSH Besides SR- N  function,add one set heater used to reduce high temp and electrical heating function
Expansion tank 100L 200L 280L 390L 500L
Heat exchanger area 3.5m2 5m2 8m2 12.5m2 20m2
Electric heating function H 25KW 35KW 50KW 65KW 80KW
With “H” has heating function
Control mode Feed forward PID + Our special dynamic control calculation,LNEYA PLC controller
Communication protocol MODBUS RTU protocol,RS485 interface,optional Ethernet interface/R232 interface
Temperature control selection Material control temp
Temperature feedback The temperature of three points: the inlet and outlet of heat-conducting medium, material in reactor(External temperature sensor), PT100 sensor
Material temp. feedback:PT100 or 4~20mA or communication given
Temp.feedback:PT100
Process temp. feedback
feedback:PT100
Temperature accuracy ±1℃ ±1℃ ±1℃ ±1℃ ±1℃
Circulation pump 200L/min 2.5BAR 250L/min 2.5BAR 400L/min 2.5BAR 500L/min 2.5BAR 750L/min 2.5BAR
Input and display 7-inch color touch screen,temperature graph display
Safety protection Self-diagnosis function;freezer overload protection;high pressure switch;overload relay;thermal protection device;liquid low level protection;high temp. Protection and temp. fault protection.
Perform valve Electric proportional control valve, control signal 4~20mA.
Piping material SUS304
Connection size DN40 DN40 DN-50 DN-65 DN-80
Dimension mm 1000*1200*1750 1250*1250*2000 1500*1500*2050 2050*1450*2050 2050*1450*2050
Power
AC380V50HZ
2.3kw(max) 3.5kw(max) 4.5kw(max) 8kw(max) 10.5kw(max)
With H power
AC380V 50HZ
27.3kw(max) 38.5kw(max) 54.5kw(max) 73kw(max) 90.5kw(max)
Case material SUS 304 SUS 304 SUS 304 SUS 304 SUS304
Latest News
    展开更多
    Get Free Quote Plan

    loading...

    Get Free Quote Plan

    loading...

    购物车

    X

    我的足迹

    X
    keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller