Precautions for the Use of 150kW Low Temperature Chiller

분류업계 뉴스 262

Precautions for the Use of 150kW Low Temperature Chiller

 

The 150kW low-temperature chiller adopts a closed screw compressor, supplemented by an efficient heat exchanger, and adopts a PLC microcomputer controller and a color touch screen, so that the unit has the characteristics of compact appearance, reasonable layout, and convenient use and maintenance. Users can put into operation as long as they connect the pipeline of the chilled water system, the pipeline of the cooling water system and the required power supply.

1. The circulating pump of the 150kW low-temperature chiller is suitable for the overshoot reaction of rapid exothermic and endothermic reaction in a short time, and the magnetic drive non-leakage pump with high temperature and low temperature resistance reduces the risk of leakage. At the same time, it has a series of advantages such as low noise, large flow, long lift, large flow rate, and low calorific value.

2. Through the single-machine self-cascading refrigeration process, the compressor can work well regardless of high temperature or low temperature.

3. The electronic expansion valve has a wide temperature range. The electronic expansion valve used can accurately control the number of steps of the stepper motor, so as to accurately control the opening of the electronic expansion valve, so as to accurately control the evaporation of the compressor refrigerant. .

4. The refrigerant pressure gauge of the 150kW low-temperature chiller, some equipment are equipped with a refrigerator pressure gauge to indicate the pressure of the refrigerator, and the state of the compressor can be judged accordingly.

5. When selecting thermal insulation materials for 150kW low temperature chillers, the temperature range of the equipment should be considered first, and flame retardant materials should be selected. The suitable temperature range of thermal insulation materials should include the temperature range of the equipment, with a margin greater than 30 degrees. There is a possibility of fire when the user ignores this problem. The thermal insulation material should be wrapped in sufficient amount, otherwise the equipment control may not achieve the expected effect.

6. The 150kW low-temperature chiller should be installed in an area far away from the noise-sensitive area, and the shock-absorbing pad should be installed under the bracket of the unit.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


저온 냉각기

워터 칠러

온도 제어 범위: -150°C ~ +50°C

 


냉난방 시스템

동적 온도 제어 시스템

온도 제어 범위: -120°C ~ +350°C

 

 


배터리 냉각 시스템

자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

 


반도체 테스트 냉각기

반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

 


산업용 냉동고

산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
무료 견적 요금제 받기

로딩 중...

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기