Generally, the chiller is equipped with a complete set of protection devices. When the chiller has a high pressure alarm, it will automatically start the protection device, and the corresponding fault indicator will light up. At this time, the chiller will stop and not run, and the operator needs to check through the following methods, or guide the operation through the chiller manufacturer.

1. If the high pressure alarm occurs in the water-cooled chiller, it is mainly related to the cooling water system. The water-cooled chiller provides circulating cooling water through a cooling water tower. If you forget to open the cooling water valve when using it, so that the cooling water cannot be circulated to the chiller, a high pressure fault will occur. In addition, check whether the cooling water tower has The failure results in the inability to deliver cooling water safely and stably.

2. The cooling water flow is too small, or the temperature is too high and the heat dissipation is not good. This problem will also occur. If the cooling water flow is small, it is necessary to check whether the size of the installed pipeline matches the size of the chiller, or whether the water valve is opened to the large position. If it is an air-cooled chiller, we need to check whether the installation ambient temperature exceeds 40°C. If it exceeds, the heat must be discharged in time to ensure that the chiller is in an environment with air circulation.

3. If the chiller is used for a long time, it is easy to cause debris such as scale to accumulate on the tube wall or the copper tube of the condenser, which will inevitably affect the refrigeration cycle system. Therefore, we should regularly maintain and clean the chiller according to the maintenance time recommended by the manufacturer. work (cleaning the cooling water system, cleaning the condenser, changing filters, etc.).

4. Check whether the refrigerant is too much. The chiller will be filled with an appropriate amount of refrigerant before leaving the factory. Therefore, if there is no refrigerant leakage, the user does not need to add refrigerant. Too much refrigerant will only affect the normal use of the equipment.

5. Whether the opening of the expansion valve is too small, you can slowly adjust the opening of the expansion valve to troubleshoot.

우리는 온도 제어 장비의 전문 제조업체로 맞춤형 서비스를 지원합니다. 문의하기 자세한 내용을 확인하세요!

 


저온 냉각기

워터 칠러

온도 제어 범위: -150°C ~ +50°C

 


냉난방 시스템

동적 온도 제어 시스템

온도 제어 범위: -120°C ~ +350°C

 

 


배터리 냉각 시스템

자동차 테스트 냉각기

온도 제어 범위: -40°C ~ +100°C

 

 


반도체 테스트 냉각기

반도체 테스트 냉각기

온도 제어 범위: -85°C ~ +250°C

 

 


산업용 냉동고

산업용 냉장고

온도 제어 범위: -150°C ~ -10°C

저작권 정보는 lneya-online.com에 귀속되며 자세한 내용은 이메일로 문의하시기 바랍니다: lilia@lneya.com

또는 아래의 WhatsApp 또는 WeChat QR 코드를 스캔하여 문의하세요. 

왓츠앱 위챗

스캔

이전: 다음:
무료 견적 요금제 받기

로딩 중...

购物车

X

我的足迹

X
키워드: 키워드병에 담긴 기쁨 물 냉각기