Air Cooled Chillers For Sale

분류업계 뉴스 152

Air Cooled Chillers For Sale

 

Features of air cooled chillers:

1. The compressor adopts a scroll type hermetic compressor and electric control components, and is equipped with a condenser and an evaporator made of high-quality copper tubes with high heat exchange efficiency;

2. Equipped with various safety protection devices, with stable performance, low noise, long service life and simple operation; LCD human-machine interface is adopted, which is simple and convenient to operate, and the operating status is clear at a glance;

3. Air cooled chillers adopt single compressor or multi-compressor combined refrigeration system. The compressors can automatically run alternately according to load changes, balancing the running hours of each compressor, achieving the effect of saving energy and extending the service life of the chiller. Facilitate energy regulation, more energy saving at partial load;

4. Air cooled chillers adopt shell box structure, beautiful appearance and compact structure, and can check the operation of the unit at any time; the unit can have its own water tank and circulating water pump according to the cooling capacity, without cooling tower and cooling water pump, easy to install and maintain ;

The basic composition of the refrigeration system of air cooled chillers:

콘덴서: 냉동 과정에서 콘덴서는 열 에너지를 출력하고 냉매를 응축하는 역할을 합니다. 냉동 컴프레서에서 배출된 고압 과열 증기가 콘덴서로 들어가면 증발기와 냉동 컴프레서에서 흡수된 열과 배관 내에서 흡수된 열을 포함하여 작업 과정에서 흡수된 모든 열을 주변 매체(물 또는 공기)로 전달하여 빼앗아갑니다. 냉매의 고압 과열 증기는 다시 액체로 응축됩니다. (냉각 매체와 냉각 방식에 따라 콘덴서는 수냉식 콘덴서, 공냉식 콘덴서, 증발식 콘덴서의 세 가지 범주로 나눌 수 있습니다.)

Liquid reservoir: The liquid reservoir is installed after the condenser and is directly connected to the drain pipe of the condenser. The refrigerant liquid in the condenser should flow into the liquid receiver unimpeded, so that the cooling area of the condenser can be fully utilized. On the other hand, when the heat load of the evaporator changes, the demand for refrigerant liquid also changes accordingly, and at that time, the liquid receiver plays the role of adjusting and storing the refrigerant. For the small chiller refrigeration system, the liquid receiver is often not installed, but the condenser is used to adjust and store the refrigerant.

Drying filter: In the refrigeration cycle of the chiller, moisture and dirt (oil, iron filings, copper filings) must be prevented from entering. The source of moisture is mainly the trace moisture contained in the newly added refrigerant and lubricating oil, or due to Moisture from air ingress during system servicing. If the moisture in the system is not removed, when the refrigerant passes through the throttling valve (thermal expansion valve or capillary tube), the moisture will sometimes freeze into ice due to the drop in pressure and temperature, blocking the passage and affecting the normal operation of the refrigeration device. Therefore, a dry filter must be installed in the chiller refrigeration system.

증발기: 증발기는 냉매 액체의 증발(실제로는 끓음)에 의존하여 냉각된 매체의 열을 흡수하는 열 교환 장치입니다. 냉동 시스템에서 증발기의 기능은 열을 흡수(또는 냉각 출력)하는 것입니다. 증발 과정이 안정적이고 지속적으로 수행될 수 있도록 하기 위해서는 일정한 증발 압력을 유지하기 위해 냉동 컴프레서에서 증발 가스를 지속적으로 펌핑해야 합니다.

Thermal expansion valve: The thermal expansion valve is not only a flow regulating valve in the chiller refrigeration system, but also a throttle valve in the refrigeration equipment. It is installed between the dry filter and the evaporator in the refrigeration equipment. Its temperature sensor It is wrapped around the outlet of the evaporator. Its main function is to make the high-pressure and normal-temperature refrigerant liquid throttling and reducing pressure when it flows through the thermal expansion valve, turning into low-temperature and low-pressure refrigerant wet vapor (mostly liquid, a small part is steam) into the evaporator, and vaporized in the evaporator absorb heat, and achieve the purpose of cooling and cooling.

 

비즈니스를 위한 맞춤형 솔루션


 

저온 냉각기

저온 냉각기(수냉식 및 공냉식)

온도 제어 범위: -150°C ~ -5°C

당사는 -150°C의 낮은 온도 제어 범위를 갖춘 저온 냉각기 생산을 전문으로 하며, 다양한 산업의 냉장 요구 사항을 충족할 수 있습니다.

온도 범위 -25°C ~ -5°C 시리즈 -45°C ~ -10°C 시리즈 -60°C ~ -10°C 시리즈 -80°C ~ -30°C 시리즈 -110°C ~ -50°C 시리즈
냉각 용량최대 360kW최대 360kW최대 360kW최대 270kW최대 180kW

 


재순환 냉각기

재순환 냉각기 (수냉식 및 공냉식)

온도 제어 범위: -120°C ~ +30°C

당사의 재순환 냉각기는 저온 냉동 기술을 채택하고 온도가 -120℃까지 낮으며 다양한 액세서리를 사용자 정의 할 수 있습니다.

온도 범위 -25°C ~ +30°C 시리즈 -45°C ~ +30°C 시리즈 -60°C ~ -20°C 시리즈 -80°C ~ -20°C 시리즈 -120°C ~ -70°C 시리즈
냉각 용량최대 38kW최대 12kW최대 7.2kW최대 7.2kW최대 8.6kW

 


물 냉각기

실온 냉각기/소형 냉각기

온도 제어 범위: +5°C ~ +50°C

이 냉각기는 다양한 산업 및 실험실에서 널리 사용될 수 있으며 맞춤형 설계를 지원합니다.

온도 범위 -18°C ~ +30°C +5°C ~ +35°C 시리즈
냉각 용량최대 0.9kW최대 50kW

 


직접 냉각 기계

 

직접 냉각식 냉동 장비

온도 제어 범위: -120°C ~ -10°C

열 교환 면적이 작고 열 교환이 큰 장소에 적합합니다.

 

온도 범위 -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
압축기 전력최대 8HP최대 8HP*2최대 45HP*3

 


 

직접 냉각식 초저온 냉각기

온도 제어 범위: -150°C ~ -110°C

비즈니스를 위한 맞춤형 솔루션.

 

온도 범위 -150°C ~ -110°C
냉각 용량최대 11kW

 


스크류 냉각기

 

스크류 냉각기

저온 스크류 냉각기 및 실온 스크류 냉각기

비즈니스를 위한 맞춤형 솔루션.

 

 

온도 범위 +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
냉각 용량최대 1027kW(단일 컴프레서)최대 2134kW(듀얼 컴프레서)최대 934kW(단일 컴프레서)최대 1940kW(듀얼 컴프레서)최대 467kW(단일 컴프레서)최대 497kW(단일 컴프레서)

 