Search the entire website

Vapour Compression Chiller

ClassificationIndustry News 359 0

Vapour Compression Chiller

Contact us today for the perfect temperature control solution

 

Vapor compression refrigeration or vapor compression refrigeration systems in which the refrigerant undergoes a phase change is one of many refrigeration cycles and is the most widely used method for air conditioning in buildings and automobiles. It is also used in household and commercial refrigerators, large warehouses for refrigerated or frozen food and meat, refrigerated trucks and railroad cars, and many other commercial and industrial services. Refineries, petrochemical and chemical processing plants, and natural gas processing plants are among the many types of plants that frequently use large vapor compression refrigeration systems. Multi-stage refrigeration systems can also be implemented using two compressors.

A vapor compression chiller uses circulating liquid refrigerant as a medium to absorb and remove heat from the space to be cooled, and then discharges the heat elsewhere. All such systems have four components: a compressor, a condenser, a metering device or thermal expansion valve (also called a throttle valve), and an evaporator. The circulating refrigerant enters the compressor in a thermodynamic state called saturated vapor and is compressed to a higher pressure, resulting in a higher temperature. The hot compressed steam is then in a thermodynamic state called superheated steam, and it is at a temperature and pressure where it can be condensed with cooling water or cooling air flowing through the coils or pipes.

 

Vapour Compression Chiller

 

The superheated steam then passes through the condenser. This is where heat is transferred from the circulating refrigerant to the external medium, causing the gaseous refrigerant to cool and condense into a liquid. The rejected heat is removed by water or air, depending on the type of condenser.

The condensed liquid refrigerant, which is in a thermodynamic state called a saturated liquid, next passes through an expansion valve where there is a sudden reduction in pressure. This pressure reduction causes adiabatic flash evaporation of a portion of the liquid refrigerant. The automatic refrigeration effect of adiabatic flash reduces the temperature of the liquid and vapor refrigerant mixture to a point below the temperature of the enclosed space to be cooled.

The cold refrigerant liquid and vapor mixture then passes through coils or tubes in the evaporator. Air in an enclosed space circulates in coils or ducts due to thermal convection or fans. Because the air is warmer than the cold liquid refrigerant, the transferred heat cools the air and causes the liquid to evaporate, causing it to return to its gaseous state while absorbing heat. When the liquid remains in the refrigerant stream, its temperature does not rise above the boiling point of the refrigerant, which is determined by the pressure in the evaporator. Most systems are designed to evaporate all refrigerant to ensure that no liquid returns to the compressor.

To complete the refrigeration cycle, the refrigerant vapor from the evaporator becomes saturated steam again and is sent back to the compressor. Over time, the evaporator may collect ice or water from ambient humidity. The ice melts through defrost and water from the melted ice or evaporator then drips into the drip pan and the water is carried away by gravity or a condensate pump.

 

request

Email: info@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

 


 

Cooling Chillers                                                                                                     

 

recirculating chiller

Recirculating Chillers / Refrigerated Circulator

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range  -25°C ~ +30°C series  -45°C ~ +30°C series  -60°C ~ -20°C series  -80°C ~ -20°C series  -120°C ~ -70°C series
Cooling Capacity 0.8 ~ 30kW 0.75 ~ 12kW 0.4 ~ 6kW 0.2 ~ 6kW 0.3 ~ 5kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Precision Chillers / Small ChillersWater Chillers / Small Chillers

(Custom Designs)

The chiller can be widely used in various industries and laboratories, and supports customized design.

 

 

Temperature range  -18°C ~ +30°C  +5°C ~ +35°C series
Cooling Capacity 0.35 ~ 0.9kW 1.8 ~ 50kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

low temperature chiller

Low Temperature Chillers

(Custom Designs)

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

 

 

Temperature range  -25°C ~ -5°C series  -45°C ~ -10°C series  -60°C ~ -10°C series  -80°C ~ -30°C series -110°C ~ -50°C series  -150°C ~ -110°C series
Cooling Capacity 12 ~ 360kW 6 ~ 180kW 6 ~ 180kW 4 ~ 180kW 2 ~ 120kW 2.5 ~ 11kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 

Cooling and Heating Chillers                                                                            

 

Cooling and Heating Chillers

(Custom Designs)

Temperature Control Range: -120°C to +350°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Temperature range  -10 ~ +150°C series  -25 ~ +200°C series  -25 ~ +300°C series  -45 ~ +250°C series  -45 ~ +300°C series  -60 ~ +250°C series  -60 ~ +300°C series  -70 ~ +250°C series  -80 ~ +250°C series -90 ~ +250°C series  -100 ~ +100°C series
Cooling Capacity 1.5 ~ 15kW 1 ~ 200kW 1 ~ 200kW 0.45 ~ 200kW 0.9 ~ 25kW 0.25 ~ 60kW 0.75 ~ 25kW 0.4 ~ 15kW 0.3 ~ 80kW 0.2 ~ 80kW 0.45 ~ 80kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 


 

Recirculating Heater Chillers

(Custom Designs)

Temperature Control Range: -45°C to +250°C

Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.

 

Temperature range  -25°C ~ +200°C series  -45°C ~ +250°C series
Cooling Capacity 1 ~ 15kW 0.25 ~ 15kW
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Latest News
Request a Quote
Name
Email Address
Phone
Company
Message