Typical applications of refrigeration heating temperature control system:
Dynamic constant temperature control of cold and heat sources of high-pressure reactor, dynamic constant temperature control of cold and heat sources of double-layer glass reactor, dynamic constant temperature control of cold and heat sources of double-layer reactor and constant temperature control of cold and heat sources of microchannel reactor; Small constant temperature control system, temperature control of steam saturation system, material low-temperature and high-temperature aging test, combined chemical cold and heat source constant temperature control, semiconductor equipment cooling and heating, vacuum chamber refrigeration and heating constant temperature control.
Structure and principle of Dynamic Temperature Control System:

Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with oxygen in the air (and the temperature of the expansion tank is between normal temperature and 60℃), which can reduce the risk of heat transfer medium being oxidized and absorbing water in the air. At high temperature, no heat conducting medium evaporates, and continuous temperature control of – 80℃ ~ 190℃, – 70℃ ~ 220℃, – 88℃ ~ 170℃, – 55℃ ~ 250℃ and – 30℃ ~ 300℃ can be realized without pressurization.

Model |
SUNDI-9A15W |
Temp. range |
-90℃~+250℃(the system add pressure 3bar) |
Control Mode |
Feedback PID + Our special dynamic control calculation, PLC controller |
Temp. control |
Process temp. control and jacket temp. control model |
Temp. difference |
Set or control the temperature difference between jacket oil and raw material process |
Program Editor |
10 programs, each program can edit 42 steps. |
Communication Portocol |
MODBUS RTU Protocol,RS485 interface |
Material temp. feedback |
PT100 OR 4~20mA or communication(normal: PT100) |
Temp. feedback |
The temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor) |
Medium temp. acccuracy |
±0.5℃ |
Material temp. accuracy |
±1℃ |
Heating power kW |
15 |
Cooling capacity kW at |
250℃ |
15 |
0℃ |
15 |
-40℃ |
12 |
-60℃ |
6 |
-80℃ |
2.1 |
-85℃ |
1.3 |
Circulation pump max
L/min bar |
110 |
2.5 |
Pump |
LNEYA magnetic drive pump |
Compressor |
Dorin semi-closed compressor |
Expansion valve |
Emerson thermal expansion valve/Emerson electronic expansion valve/danfoss thermal expansion valve. |
Evaporator |
DANFOSS/KAORI Plate heat exchanger |
Operation Panel |
7-inch touch screen,show temp curve\EXCEL data output |
Safety protection |
Self-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection. |
Closed circulation system |
The whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature. |
Refrigerant |
R404A/R23/R14 mixture,optional: R125/R23/R14 mixture |
Connection size |
DN32 PN10 |
Water-cooled type W(cooling water@20℃) |
8m³/H
1.5bar~4bar |
Dimension cm |
100*150*185 |
Weight kg |
950 |
Power 380V 50HZ |
38kW |




LNEYA attends various exhibitions at home and abroad every year. At the exhibition, we show the latest research equipment of LNEYA. Every year, long-term cooperative customers will come to exhibitions and communicate with us. We are also actively developing new customers to provide them with high quality machines and services.
After sale service
Quality assurance
Guarantee that the goods are sold to be conform to the provisions of the contract and qualified new products by factory inspection, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract.
Installation and debugging
After the arrival of the goods, my company or my company agent is responsible for installation and debugging of equipment need on-site installation and debugging.
Inspection and acceptance
After installation and debugging, acceptance by the customer to confirm the goods to be conform to the provisions of the contract and qualified new products, quality performance, technical indicators and configured are in accordance with manufactures and technical documents stipulated in the contract, and after the confirmation of a full set of technical documents, sign the installation acceptance report and confirm acceptance.
Training
At the same time of installation and debugging of equipment, my company’s after-sales service engineer is responsible for technical training for user until user can be skilled of operation. In the process of using equipment by customer, customer can consult relevant technical issues to after-sales service personal of our company at any time, according to the situation, my company will arrange training on site or remote.
After sale service commitment
A full free one year warranty since the date of acceptance, during the warranty period, all repairs and spare parts are free of charge(instrukent malfunction caused bu human factors will be charged of cost price of spare parts); After the warranty period, we will be responsible for maintenance of equipment for lifetime, according to the actual maintenance fees, appropriate fee will be charged.
(PS:There will have extra charge if the customer need on-site service. And customers need to describe the issue first and then send some failed pics or videos in advance, then Lneya judge if it is possible to go for after-Sales on site. )