Pharmaceutical Reactor Refrigeration and Heating System
The Pharmaceutical Reactor Refrigeration and Heating System controls the temperature of the material through the temperature change of the circulating medium in the jacket or coil to achieve the target temperature of the control material. For the temperature control of the reactor in the chemical and pharmaceutical industries, the selection requirements for temperature control equipment Higher, then, what precautions should be paid attention to when purchasing Pharmaceutical Reactor Refrigeration and Heating System?
1. Understand the requirements of the material, quantity, size, inlet and outlet temperature, flow rate, temperature control accuracy, and temperature control time of the reactor in the temperature control process of the Pharmaceutical Reactor Refrigeration and Heating System.
2. Understand the temperature control method used by the equipment and the knowledge of the temperature control principle. The temperature control methods of different manufacturers are different.
3. Understand and analyze the quality, performance, structure, configuration, accessories, price, after-sales service, distribution, etc. of Pharmaceutical Reactor Refrigeration and Heating System, and choose the right manufacturer.
4. The temperature range of the Pharmaceutical Reactor Refrigeration and Heating System is -120°C~200°C, and the temperature control accuracy is ±1°C. The temperature requirements are set on the display screen of the device. The operation is relatively simple, and there are instructions for reference.
5. Understand the configuration of the Pharmaceutical Reactor Refrigeration and Heating System. If the accessories are all branded accessories, it will help the stable operation of the equipment, be more reliable, and can effectively meet the temperature requirements required by the project.
The Pharmaceutical Reactor Refrigeration and Heating System is a temperature control equipment used in many industries. It needs to be operated according to the manual when operating, and pay more attention to maintenance at ordinary times.
Dynamic Temperature Control Systems (Support Customization)
Cooling and Heating Systems (SUNDI series) (Custom Designs)
Temperature Control Range: -120°C to +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | -25 ~ +200°C one machine for two reactors | -40 ~ +200°C one machine for two reactors |
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | up to 10*2kW | up to 10*2kW |
Cooling and Heating Systems (WTD series) (Custom Designs)
(Micro channel / tube reactors specialized)
Temperature Control Range: -70°C to +300°C
Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW |
Cooling and Heating Systems (TES series) (Custom Designs)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | 0.3 ~ 25kW | 0.25 ~ 25kW | 3 ~ 60kW |
Cooling and Heating Machines (LTS series) (Custom Designs)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Cooling and Heating Circulators (Custom Designs)
Temperature Control Range: -45°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series |
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW |
Heating Circulators (Custom Designs)
Temperature Control Range: +50°C to +300°C
Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.
Temperature range | +50°C ~ +170°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) |
Heating Capacity | 5.5 ~ 15kW | 3.5 ~ 130kW | 3.5 ~ 95kW |
TCU Multi-reactors Temperature Control System (Custom Designs)
Temperature Control Range: -120°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C |
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW |