Regular maintenance must be done after purchasing low temperature glycol chiller, which can prolong the life of low temperature glycol chiller, reduce equipment failure, avoid production impact, and reduce company maintenance costs. So how should low temperature glycol chiller be maintained?

1. If the low temperature glycol chiller has an alarm fault, you can press the alarm button first, and then troubleshoot one by one. Note: Do not start the low temperature glycol chiller forcibly before troubleshooting. If you start it forcibly, it will cause unnecessary trouble and may damage the whole unit.

2. Regularly clean the condenser, evaporator, and heat dissipation pipes. I suggest that you clean them every six months to ensure that the low temperature glycol chiller will not fail.

3. After purchasing a low temperature glycol chiller and using it for a period of time, check whether the refrigeration oil and lubricating oil are contaminated. If so, please replace it immediately to ensure that the compressor can operate normally, thereby increasing work efficiency.

4. The water-cooled low temperature glycol chiller needs to clean the cooling tower and the impurities in the water tank, because there are various impurities in the tap water, and dirt will accumulate after long-term use.

5. Air-cooled low temperature glycol chiller should pay attention to, after starting up, first check whether the direction of the fan is correct. If the fan is reversed, it may be that the power cord is reversed. At this time, just turn off the chiller, adjust the direction of the fan and start it again. OK.

6. Before installing the low temperature glycol chiller, you must choose a good location and place it in a place where the surrounding air circulates, so as to ensure that the low temperature glycol chiller has a good heat dissipation environment and avoid high temperature alarms.

7. Check whether the filter is normal, or if it is clogged, it must be replaced in time to ensure the normal operation of the low temperature glycol chiller.

 

Customized Solutions For Your Business


 

low temperature chiller

Low Temperature Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -150°C to -5°C

We specialize in the production of low-temperature chillers with a temperature control range as low as -150°C, which can meet the refrigeration needs of different industries.

Temperature range -25°C ~ -5°C series -45°C ~ -10°C series -60°C ~ -10°C series -80°C ~ -30°C series -110°C ~ -50°C series
Cooling Capacityup to 360kWup to 360kWup to 360kWup to 270kWup to 180kW

 


recirculating chiller

Recirculating Chillers (Water Cooled & Air Cooled)

Temperature Control Range: -120°C to +30°C

Our recirculating chiller adopts low-temperature refrigeration technology, the temperature is as low as -120℃, and various accessories are customizable.

Temperature range -25°C ~ +30°C series -45°C ~ +30°C series -60°C ~ -20°C series -80°C ~ -20°C series -120°C ~ -70°C series
Cooling Capacityup to 38kWup to 12kWup to 7.2kWup to 7.2kWup to 8.6kW

 


water chiller

Room Temperature Chillers / Small Chillers

Temperature Control Range: +5°C to +50°C

The chiller can be widely used in various industries and laboratories, and supports customized design.

Temperature range -18°C ~ +30°C +5°C ~ +35°C series
Cooling Capacityup to 0.9kWup to 50kW

 


Direct Cooling machine

 

Direct Cooling Type Refrigeration Equipments

Temperature Control Range: -120°C to -10°C

It is suitable for places with small heat exchange area and large heat exchange.

 

Temperature range -40°C ~ -10°C -80°C ~ -35°C -120°C ~ -90°C
Compressor Powerup to 8HPup to 8HP*2up to 45HP*3

 


 

Direct Cooling Ultra Low Temp Chillers

Temperature Control Range: -150°C to -110°C

Customized solutions for your business.

 

Temperature range -150°C ~ -110°C
Cooling Capacityup to 11kW

 


screw-chillers

 

Screw Chillers

Low temperature screw chillers and room temperature screw chillers

Customized solutions for your business.

 

 

Temperature range +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C +5°C ~ +30°C -25°C ~ +5°C -25°C ~ +5°C
Cooling Capacityup to 1027kW (Single Compressor)up to 2134kW (Dual Compressor)up to 934kW (Single Compressor)up to 1940kW (Dual Compressor)up to 467kW (Single Compressor)up to 497kW (Single Compressor)

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous: Next:
Get Free Quote Plan

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller