Laboratory Recirculating Heater/Chiller
As a laboratory equipment, laboratory recirculating heater/chiller can ensure the accuracy and stability of material testing.
Working principle of laboratory recirculating heater/chiller
Laboratory recirculating heater/chiller is a device used to control the experimental temperature, which can quickly heat up and cool down within the set temperature range. It realizes precise control of temperature through built-in refrigeration system and heating system. High and low temperature circulators are usually equipped with temperature sensors and control systems to ensure the stability and uniformity of temperature during the experiment.
The importance of laboratory recirculating heater/chiller control
Laboratory environment control is of great significance for scientific research. In material testing, temperature is one of the key factors affecting experimental results. By accurately controlling the experimental temperature, the influence of temperature fluctuations on experimental results can be eliminated, thereby improving the reliability and accuracy of experimental data. In addition, a stable experimental environment also helps to ensure the repeatability and comparability of the experiment, providing strong support for scientific research and industrial production.
Application of laboratory recirculating heater/chiller in material testing
1. Material thermal performance test: laboratory recirculating heater/chiller can be used to test thermal performance parameters such as thermal expansion coefficient and thermal conductivity of materials. By testing the material at different temperatures, its performance in practical applications can be evaluated.
2. Material weathering test: It can simulate the environment that the material may encounter during actual application to evaluate the weathering resistance and reliability of the material.
3. Material mechanical property test: The high and low temperature circulator can be used to test the mechanical properties of the material at different temperatures, such as tensile strength, yield strength, etc. This helps to understand the performance changes of the material under complex environments.
4. Material structure analysis: The high and low temperature circulator can be used for material structure analysis, such as crystal structure, phase change, etc. By analyzing the material at different temperatures, the law of material structure change with temperature can be revealed.
Advantages of laboratory recirculating heater/chiller
1. Precision control: With a high-precision temperature control system, it can achieve precise control of temperature and ensure the accuracy of experimental results.
2. Stability: It can run stably for a long time within the set temperature range to provide a stable temperature environment for the experiment.
3. Uniformity: Through reasonable structural design, the uniformity of temperature during the experiment is ensured and the reliability of experimental data is improved.
4. Safety: It has complete safety protection functions, such as over-temperature protection, over-voltage protection, etc., to ensure the safety of the experimental process.
5. Ease of use: It usually has a user-friendly operating interface and a simple control system to facilitate the operation of experimental personnel.
The laboratory recirculating heater/chiller plays an important role in laboratory environmental control and provides a strong guarantee for the accuracy and stability of material testing.
We provide complete temperature control systems design and manufacturing. From standard models to complete customized products. We specialize in customer service and are dedicated to helping each customer have the optimal temperature control system for their specific need.
We provide non-standard customized solutions. Both single cooling chillers and cooling & heating combo units are available.
Email: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 15251628237
1.Cooling and Heating Systems
Cooling and Heating Systems (SUNDI series)
- Temperature range: -120℃ ~ +350℃
- High-precision, intelligent temperature control
- Cooling capacity: 0.5kW ~ 1200kW
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -10 ~ +150°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | ||
Cooling Capacity | 1.5 ~ 15kW | 1 ~ 200kW | 1 ~ 200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Circulators
- Temperature range: -45℃ ~ +250℃
- Emerson Copeland compressor, reliable quality
- Self-diagnosis function, multiple safety protection devices
- Fully closed system to extend the service life of thermal fluid
- Each device is load tested for more than 12 hours
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series | |||||||
Cooling Capacity | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Cooling and Heating Systems (WTD series)
- (Micro channel / tube reactors specialized)
- Temperature range: -70℃ ~ +300℃
- High-performance circulation pump, more stable temperature control effect
- Wide temperature range to meet the needs of more industries
- Each device is load tested for more than 12 hours
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
Cooling Capacity | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
TCU Multi-reactors Temperature Control System
- Temperature range: -120℃ ~ +250℃
- Sealed, repeatable temperature control
- Built-in electric heating thermal oil auxiliary system
- Add cold and heat source heat exchange modules according to needs
- Each device is load tested for more than 12 hours
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C | |||||
Heating Capacity | 25 ~ 80kW | 25 ~ 80kW | Custom | 25 ~ 300kW | |||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
2.Cooling Chillers
Low Temperature/Cryogenic Chillers (Water Cooled)
- Temperature range: -150℃ ~ -5℃
- International brand compressor, high cooling efficiency
- Secondary subcooling technology, fast cooling speed
- Automated control and operation, efficient and energy-saving
- Each device is load tested for more than 12 hours
Six product series
Temperature range | -25°C ~ -5°C | -45°C ~ -10°C | -60°C ~ -10°C | -80°C ~ -30°C | -110°C ~ -50°C | -150°C ~ -110°C | |||
Cooling Capacity | 12kW…360kW | 6kW…180kW | 6kW…180kW | 4kW…180kW | 2kW…120kW | 2.5kW…11kW | |||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Recirculating Chiller/Refrigerated Circulator (Air Cooled)
- Temperature range: -120℃ ~ +30℃
- International brand compressor, cascade refrigeration technology
- Use ethylene glycol or a mixture of ethylene glycol and water
- Fully sealed design to ensure the purity of the medium
- Each device is load tested for more than 12 hours
Five product series
Temperature range | -25°C ~ +30°C | -45°C ~ +30°C | -60°C ~ -20°C | -80°C ~ -20°C | -120°C ~ -70°C | ||||
Cooling Capacity | 0.8kW…30kW | 0.75kW…12kW | 0.4kW…6kW | 0.2kW…6kW | 0.3kW…5kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
Small Chillers / Mini Chillers
- Temperature range: -18℃ ~ +35℃
- International brand compressor, stable performance
- Microcomputer controller, adjustment unit 0.1℃
- Energy saving, high temperature control accuracy
- Each device is load tested for more than 12 hours
Two product series
Temperature range | -18°C ~ +30°C | +5°C ~ +35°C | |||||||
Cooling Capacity | 0.35 ~ 0.9kW | 1.8kW…50kW | |||||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |
High Temperature Chillers
- Temperature range: -100℃ ~ +80℃
- International brand compressors and other accessories
- Fully sealed design to ensure the purity of the medium
- PLC programmable controller
- Each device is load tested for more than 12 hours
Five product series
Temperature range | +5°C ~ +40°C | -25°C ~ +40°C | -45°C ~ +40°C | -80°C ~ +80°C | -100°C ~ +80°C | ||||
Cooling Capacity | 6kW…40kW | 2kW…15kW | 1kW…8kW | 0.kW…3kW | 1.5kW…3kW | ||||
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized |