Laboratory heater chiller circulator plays a vital role in scientific research, drug development, chemical analysis and other fields. These systems not only ensure the stability and accuracy of the experimental environment, but also improve the efficiency and safety of the experiment.

The following are several advantages of laboratory heater chiller circulator:

1. High temperature control accuracy

• Accurate temperature control: Laboratory equipment is usually equipped with advanced sensors and control systems, which can achieve temperature control accuracy of ±0.1°C or even higher. This ensures high consistency and stability of temperature during the experiment, which is particularly important for experiments that require strict temperature control.

• Fast response: Efficient heat exchangers and advanced control systems enable the equipment to adjust the temperature in a short time, adapt to changes in experimental conditions, reduce waiting time, and improve experimental efficiency.

2. Wide operating temperature range

• Excellent low temperature performance: The refrigeration system can reach extremely low temperatures (such as -80°C or lower), which is suitable for application scenarios such as cryopreservation of biological samples and low temperature reactions.

• High temperature stability: The heating system can provide temperatures up to 300°C or even higher, meeting a variety of experimental needs such as high temperature reactions, distillation, and drying.

3. Antifreeze and anticorrosion protection

• Antifreeze properties: For systems using ethylene glycol or other antifreeze as heat transfer media, it can effectively prevent the liquid from freezing and avoid damage to pipes or equipment due to freezing. It is especially suitable for cooling systems used outdoors in winter.

• Anticorrosion protection: Many laboratory equipment are made of corrosion-resistant materials such as stainless steel and glass, and corrosion inhibitors are added to extend the service life of the equipment and reduce maintenance costs.

4. Energy saving and environmental protection

• High efficiency: The equipment uses efficient compressors, electric heaters and heat exchangers, with a high overall energy efficiency ratio, which can save a lot of energy costs in long-term use.

• Environmentally friendly design: Modern laboratory equipment pays attention to environmental protection, uses fluorine-free refrigerants, biodegradable heat transfer media, etc., reduces the impact on the environment, and meets green laboratory standards.

5. Safe and reliable

• Multiple safety guarantees: Built-in safety mechanisms such as over-temperature protection, leak detection, and pressure monitoring ensure safe operation of the equipment and reduce the risk of accidents.

• Low toxicity: Even when using toxic heat transfer media (such as ethylene glycol), closed system operations are usually adopted to reduce the risk of harm to humans and the environment.

 

Laboratory Heater Chiller Circulator

 

6. Intelligent control

• High degree of automation: Modern laboratory equipment is usually equipped with PLC controllers or higher-level automation control systems to achieve precise temperature control and remote monitoring.

• Visual management: Through the display screen or remote terminal, operators can view equipment status, set parameters, historical data and other information in real time, which is convenient for management and maintenance.

7. Versatility

• One machine for multiple uses: Some equipment integrates refrigeration and heating functions in one, which can not only meet the needs of low-temperature experiments, but also perform high-temperature processing, greatly improving the utilization rate of equipment.

• Modular design: Many equipment adopt modular design, which can be flexibly configured according to experimental needs, convenient for expansion and upgrading.

8. Easy maintenance

• Stable chemical properties: The chemical properties of the heat transfer medium are stable and not easy to decompose or deteriorate, which reduces the frequency of replacement and reduces the maintenance workload.

• Modular design: Many equipment adopt modular design, which is easy to disassemble and repair, simplifying the daily maintenance process.

9. Compliance with regulations and standards

• Compliance: Laboratory equipment usually complies with international standards and industry specifications such as ISO and CE to ensure its safety and reliability.

• Complete certification: Equipment manufacturers usually provide complete certification documents and technical support to facilitate user procurement and use.

In summary, the laboratory heater chiller circulator has become an indispensable tool in modern scientific research due to its high-precision temperature control, wide operating temperature range, antifreeze and anti-corrosion protection, energy saving and environmental protection, safety and reliability, intelligent control, versatility, easy maintenance, and compliance with regulations and standards. If you have more specific questions or need further technical support, please feel free to let me know. I can provide you with more detailed suggestions or help you find a suitable solution.

 

Email: lilia@lneya.com    WeChat ID: +8615251628237    WhatsApp: +86 17851209193

scan

 

 


Heater & Chiller Combo Units (SUNDI series)

(Custom Designs)

  • Temperature range: -120℃ ~ +350℃
  • High-precision, intelligent temperature control
  • Fully closed system to extend the service life of thermal fluid

Eleven product series

Model SUNDI-1 SUNDI-2 SUNDI-23 SUNDI-4 SUNDI-43 SUNDI-6 SUNDI-63 SUNDI-7 SUNDI-8 SUNDI-9 SUNDI-10
Temperature range  -10 ~ +150 °C -25 ~ +200 °C  -25 ~ +300 °C -45 ~ +250 °C  -45 ~ +300 °C  -60 ~ +250 °C  -60 ~ +300 °C  -70 ~ +250 °C  -80 ~ +250 °C -90 ~ +250 °C  -100 ~ +100 °C
Cooling capacity 1.5 … 15 kW 1 … 200 kW 1 … 200 kW 0.45 … 200 kW 0.9 … 25 kW 0.25 … 60 kW 0.75 … 25 kW 0.4 … 15 kW 0.3 … 80 kW 0.2 … 80 kW 0.45 … 80 kW
Heating capacity 2.5 … 15 kW 2.5 … 200 kW 2.5 … 200 kW 2.5 … 200 kW 5.5 … 25 kW 2.5 … 60 kW 5.5 … 25 kW 2.5 … 15 kW 3 … 80 kW 3 … 80 kW  3.5 … 80 kW
Pump flow pressure 20 … 75 L/min 20 … 600 L/min 20 … 600 L/min 20 … 600 L/min 35 … 150 L/min 20 … 250 L/min 35 … 150 L/min 20 … 110 L/min 20 … 400 L/min 20 … 400 L/min 35 … 400 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


chiller

Frequency Conversion Heater & Chiller Combo Units

(Custom Designs)

  • Temperature range: -80℃ ~ +250℃
  • High-precision, intelligent temperature control
  • Adopt frequency conversion control to save energy

Two product series

Model SUNDIZ4 SUNDIZ8
Temperature range   -45 ~ +250 °C  -80 ~ +250 °C
Cooling capacity 0.9 … 60 kW 0.4 … 20 kW
Heating capacity 5.5 … 60 kW 3.5 … 15 kW
Pump flow pressure 50 … 400 L/min 35 … 250 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Circulators

(Custom Designs)

  • Temperature range: -45℃ ~ +250℃
  • Emerson Copeland compressor, reliable quality
  • Self-diagnosis function, multiple safety protection devices

Two product series

Model HR HRT
Temperature range   -25 ~ +200 °C  -45 ~ +250 °C
Cooling capacity 1 … 15 kW 0.25 … 15 kW
Heating capacity 2.5 … 15 kW 2.5 … 15 kW
Pump flow pressure 20 … 110 L/min 20 … 110 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Cooling and Heating Systems (WTD series)

(Custom Designs)

  • (Micro channel / tube reactors specialized)
  • Temperature range: -70℃ ~ +300℃
  • Wide temperature range to meet the needs of more industries

Three product series

Model  WTD-M  WTD-2T  WTD-PEX
Temperature range  -70 ~ +300 °C  -45 ~ +250 °C  -70 ~ +200 °C
Cooling capacity 1.1 … 7.5 kW 1.5 … 5.5 kW 11 … 50 kW
Heating capacity 2 … 7.5 kW 5.5 kW 38 … 50 kW
Pump flow pressure 7 … 25 L/min 25 L/min 250 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


Heating Circulators

(Custom Designs)

  • Temperature range: +50℃ ~ +300℃
  • Large heat exchange area and fast heating speed
  • Closed circulation system, no oil mist at high temperatures

Three product series

Model  UC-1 UC-2 UST
Temperature range +50 ~ +170 °C  +50 ~ +300 °C  +50 ~ +300 °C
Cooling capacity 1.8 … 15 kW 1 … 130 kW 1 … 95 kW
Heating capacity 5.5 … 15 kW 3.5 … 130 kW 3.5 … 95 kW
Pump flow pressure 35 … 50 L/min 35 … 400 L/min 35 … 400 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

 

 


TCU Multi-reactors Temperature Control System

(Custom Designs)

  • Temperature range: -120℃ ~ +250℃
  • Built-in electric heating thermal oil auxiliary system
  • Each device is load tested for more than 12 hours

Two product series

Model ZLF SR
Temperature range   -25 ~ +200 °C  -45 ~ +250 °C
Pump flow pressure 150 … 750 L/min 200 … 750 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com