KRY 0°C ~ +100°C 1&6S

KRY 0°C ~ +100°C 1&6S

  • Temperature Control Range: 0°C ~ +100°C 1&6S
  • Temperature Control Accuracy: ± 0.5 °C
  • Siemens PLC Control Screen And Color Touch Screen

Note: Both Air Cooled And Water Cooled Are Available. Explosion Proof Cabinet Can Be Customized.

 

Application: Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, R&D Workshop, Biological and Other Industries.

 

Request a Quote          Email Us           More Product Models

Features:

  • Multi channel output, independent control of flow, no interference with each other.
  • Temperature, flow and pressure can be controlled separately.
  • Multi channel temperature control, and one device can achieve multi channel output, and control the flow separately.
  • Strong circulation pump ensures the delivery of high viscosity liquid, it can provide high flow under stable pressure.
  • Clear circuit, compact structure, multiple fault alarm functions to ensure safe operation of the equipment.
  • Temperature variation range is usually from -40 to 100 degrees (which can be extended to 150 degrees). While controlling the temperature, you can also choose to control the flow or pressure;
  • Equipped with powerful circulating pump to ensure the delivery of high viscosity liquid; Variable frequency regulation or proportional regulation valve is used to control the flow output to achieve high-precision control of 5% ~ 100% of the total range.
  • The temperature control equipment can be flexibly connected with other test platforms;

The System Process Flow Is As Follows:

The liquid refrigerant in the evaporator of the unit is exchanged with the circulating air in the interior of the tank. The temperature rises from liquid to gas, and is sucked into the suction port of the compressor. The high-temperature and high-pressure refrigerant gas after compression by the compressor passes through The oil separator separates the refrigerating machine oil carried in the compression process, and then enters the condenser, and exchanges heat with ambient air or cooling water to change from high temperature and high pressure gas to high pressure normal temperature liquid. The high-pressure normal temperature refrigerant liquid is dried by a filter and then throttled and depressurized by an expansion valve, that is, from a high-pressure liquid to a low-pressure liquid. The low-pressure liquid (lower boiling point) enters the evaporator of the unit, and the cooling air is brought to the inside of the tank through the circulating air to achieve refrigeration.

Product features and advantages:

The anti-freeze solution is injected into the 80L pressure vessel, and the fully closed circulation system is adopted. This avoids the opportunity for the antifreeze to contact with the outside air and ensures the condensation of the water. After the expansion tank is protected by nitrogen, the temperature range of the heat transfer liquid is also broadened because its boiling point is increased. In addition, oxidation of the thermally conductive liquid in contact with oxygen in the environment is also avoided, thereby extending the useful life of the thermally conductive liquid.

Customer Case

 

ModelKRY-A25W/6SKRY-A38W/6SKRY-A60W/6S
Temp. Range0℃~+100℃
Temp. control precision±0.5℃±0.5℃±0.5℃
Temp. feedbackPt100Pt100Pt100
Temp. display0.01k0.01k0.01k
Flow control/Group2~20 L/min2~20 L/min2~20 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L
Number of fluid output groups6 Groups6 Groups6 Groups
pressure control/Group0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar
flow pressure descriptionThe equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Heating power15kW25kW38kW
cooling capacity100℃25kW38kW60kW
20℃25kW38kW60kW
5℃18kW27kW42kW
compressionEmerson Valley Wheel Compressor
expansionElectronic expansion valve
oil distributorEmerson
Dry filter, PressureDanfoss
Evaporator plate heat exchanger
Ciriulating pumpcentrifugal pump can be selected with imported brand magnetic pump
FrequencyDelta
Flow, Pressure sensorGerman brand flowmeter, johnson Controls pressure
input, Display10 inch color touch screen \ Siemens S7-1200 PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed systemThe whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerantR404A/R507C/R125/N40  All four refrigerants are available
Connection sizeThere are six groups of inlet and outlet,G3/4
Cooling water at 20C°6000L/H9000L/H15000L/H
Condenser(W)Shenshi tube type heat exchanger
Power 380V50HZ38kW55kW82kW
Dimension cm200*145*205200*145*205200*145*205
Weight900kg1200kg1950kg
Optional220V 60HZ three phase    460V 60H three phase
OptionalExtend to -40~+135℃
OptionalThe size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.
OptionalWhen the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving
ModelKRY-A25W/6SKRY-A38W/6SKRY-A60W/6S
Temp. Range0℃~+100℃
Temp. control precision±0.5℃±0.5℃±0.5℃
Temp. feedbackPt100Pt100Pt100
Temp. display0.01k0.01k0.01k
Flow control/Group2~20 L/min2~20 L/min2~20 L/min
Flow control accuracy/Group±0.2L±0.2L±0.2L
Number of fluid output groups6 Groups6 Groups6 Groups
pressure control/Group0.2bar~2.5bar0.2bar~2.5bar0.2bar~2.5bar
flow pressure descriptionThe equipment can control flow and pressure separately. need to control at the same time using different solutions (to be customized)
Heating power15kW25kW38kW
cooling capacity100℃25kW38kW60kW
20℃25kW38kW60kW
5℃18kW27kW42kW
compressionEmerson Valley Wheel Compressor
expansionElectronic expansion valve
oil distributorEmerson
Dry filter, PressureDanfoss
Evaporator plate heat exchanger
Ciriulating pumpcentrifugal pump can be selected with imported brand magnetic pump
FrequencyDelta
Flow, Pressure sensorGerman brand flowmeter, johnson Controls pressure
input, Display10 inch color touch screen \ Siemens S7-1200 PLC controller
CommunicationModbus RTU protocol RS485 interface, optional CAN communication bus, Ethernet interface TCP/IP protocol
Safety protectionWith self-diagnosis function; Refrigerator overload protection; High pressure switch, overload relay, thermal protection
device, low liquid level protection, high temperature protection, sensor fault protection and other safety functions
is it a fully closed systemThe whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature in operation, and the thermal conduction medium will be automatically supplemented at low temperature.
refrigerantR404A/R507C/R125/N40  All four refrigerants are available
Connection sizeThere are six groups of inlet and outlet,G3/4
Cooling water at 20C°6000L/H9000L/H15000L/H
Condenser(W)Shenshi tube type heat exchanger
Power 380V50HZ38kW55kW82kW
Dimension cm200*145*205200*145*205200*145*205
Weight900kg1200kg1950kg
Optional220V 60HZ three phase    460V 60H three phase
OptionalExtend to -40~+135℃
OptionalThe size external circulation pipe line is DN15 or DN20, do not throttle, which will increase the circulation pump load,
pipe need to be insulated, and adopt rubber and plastic insulation pipe which can afford high temp.
OptionalWhen the temperature is lower than the normal temperature, the refrigeration system adopts the refrigeration PID to adjust the cooling capacity, and does not adopt the heating countermeasures, so as to achieve the purpose of energy saving

Copyright information belongs to lneya-online.com, please contact email for details: lilia@lneya.com

Or scan the WhatsApp or WeChat QR code below to contact us. 

WhatsAPP                                   WeChat

scan

Previous:
Request A Quote

loading...

购物车

X

我的足迹

X
keywords:< a href="https://lneya-online.com/sitemap.html" title="water chiller"target="_blank">Bottled joy < a href="https://lneya-online.com/sitemap.xml" title="water chiller"target="_blank">water chiller