Laboratory Cooling and Heating Systems for Reactors
Laboratory heating and cooling systems are very common in fields such as chemistry, pharmaceuticals, and materials science, especially in reactor experiments that require precise temperature control. Such systems can provide fast and accurate temperature changes to meet a variety of experimental needs.
Below are some common laboratory heating and cooling systems and their characteristics
1. Circulating cooling/heating bath:
•Purpose: Control the temperature in the reactor by circulating liquid (such as water, ethylene glycol solution).
•Type: Single-stage or two-stage compressor cooling, resistance wire or electric heating rod heating.
•Features:
Wide temperature range (-40°C to +200°C).
Precise temperature control (±0.1°C).
Programmable temperature curve.
Built-in safety protection functions (such as over-temperature protection, low pressure protection, etc.).
2. Jacketed reactor supporting system:
•Purpose: Used in conjunction with jacketed reactors to heat or cool through the medium in the jacket.
•Features:
Wide temperature range (-80°C to +300°C).
High-precision temperature control.
Supports a variety of media (such as water, ethylene glycol, silicone oil, etc.).
Can achieve rapid heating and cooling.
Suitable for small-scale and pilot-scale experiments.
3. Multifunctional environmental test chamber:
• Purpose: Simulate various environmental conditions, including high temperature, low temperature, humidity changes, etc., widely used in product testing in electronics, automotive, aerospace and other industries.
• Features:
Wide temperature range (-70°C to +180°C).
Humidity control function.
Powerful programming function, can set complex temperature and humidity curves.
Suitable for a variety of sample tests.
4. Peltier effect device:
• Purpose: Use the Peltier effect for rapid heating and cooling, suitable for small reactors or microfluidic devices.
• Features:
Fast response time.
No noise, no vibration.
Compact design, suitable for desktop use.
Suitable for small experiments that require frequent temperature switching.
Key points for selecting laboratory heating and cooling systems
• Temperature range: Determine the minimum and maximum operating temperatures required based on your specific needs.
• Temperature control accuracy: Consider the temperature control requirements of the experiment and select the appropriate accuracy level.
• Capacity and flow: Select the appropriate equipment capacity and fluid flow based on actual needs.
• Safety: Ensure that the equipment has the necessary safety protection measures to prevent accidents.
• Maintenance and care: Select equipment that is easy to maintain and maintain to reduce long-term operating costs.
• Control system: Select equipment with an intelligent control system for easy setup and monitoring.
Application areas of laboratory heating and cooling systems
• Chemical synthesis: organic synthesis, catalytic reactions, etc.
• Pharmaceutical research and development: drug synthesis, extraction, purification, etc.
• Materials science: research and development and testing of new materials.
• Biotechnology: enzyme activity research, protein crystallization, etc.
If you have a specific budget range, application scenario or special requirements, please provide more details and I will provide you with more specific suggestions and recommendations. This will help you better choose a heating and cooling system that suits your laboratory needs.
완벽한 온도 제어 시스템 설계 및 제조를 제공합니다. 표준 모델부터 완벽한 맞춤형 제품까지. 고객 서비스를 전문으로 하며 각 고객이 특정 요구에 맞는 최적의 온도 제어 시스템을 갖출 수 있도록 최선을 다하고 있습니다.
비표준 맞춤형 솔루션을 제공합니다. 단일 냉각 냉각기와 냉각 및 난방 콤보 장치를 모두 사용할 수 있습니다.
이메일: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
- 온도 범위: -120℃ ~ +350℃
- 고정밀, 지능형 온도 제어
- 냉각 용량: 0.5kW ~ 1200kW
- 열 유체의 수명을 연장하는 완전 밀폐형 시스템
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -10 ~ +150°C 시리즈 | -25 ~ +200°C 시리즈 | -25 ~ +300°C 시리즈 | -45 ~ +250°C 시리즈 | -45 ~ +300°C 시리즈 | -60 ~ +250°C 시리즈 | -60 ~ +300°C 시리즈 | -70 ~ +250°C 시리즈 | -80 ~ +250°C 시리즈 | -90 ~ +250°C 시리즈 | -100 ~ +100°C 시리즈 | ||
냉각 용량 | 1.5 ~ 15kW | 1~200kW | 1~200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
- 온도 범위: -45℃ ~ +250℃
- 에머슨 코플랜드 컴프레서, 신뢰할 수 있는 품질
- 자가 진단 기능, 다중 안전 보호 장치
- 열 유체의 수명을 연장하는 완전 밀폐형 시스템
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -25°C ~ +200°C 시리즈 | -45°C ~ +250°C 시리즈 | |||||||
냉각 용량 | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
- (마이크로 채널/튜브 리액터 전문)
- 온도 범위: -70℃ ~ +300℃
- 고성능 순환 펌프, 보다 안정적인 온도 제어 효과
- 더 많은 산업의 요구를 충족하는 넓은 온도 범위
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
냉각 용량 | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
- 온도 범위: -120℃ ~ +250℃
- 밀폐된 반복 가능한 온도 제어
- 내장형 전기 난방 열유 보조 시스템
- 필요에 따라 냉기 및 열원 열교환 모듈 추가
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -45°C ~ +250°C 시리즈 | -120°C ~ +250°C 시리즈 | 맞춤형 온도 제어 시스템 | RT+10°C ~ +135°C | |||||
난방 용량 | 25 ~ 80kW | 25 ~ 80kW | 사용자 지정 | 25 ~ 300kW | |||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |