Cooling and Heating Laboratory Circulators
Refrigeration and heating laboratory circulator is a temperature control device widely used in laboratories, which can provide precise temperature control and is suitable for a variety of experiments and applications. This device usually includes a refrigeration system, a heating system and a circulation pump to adjust and maintain the target temperature through a heat transfer medium (such as water, ethylene glycol solution or silicone oil).
Main features of refrigeration and heating laboratory circulator
1. Wide temperature range:
• The general operating temperature range is from -20°C to +200°C, depending on the model.
• Some advanced models can reach lower temperatures, such as -45°C or even lower.
2. High-precision temperature control:
• The temperature control accuracy is usually between ±0.1°C and ±0.5°C.
• PID control algorithm is used to ensure temperature stability and accuracy.
3. Multiple heat transfer medium support:
• A variety of heat transfer media such as water, ethylene glycol solution, silicone oil, etc. can be used to adapt to different temperature ranges and application requirements.
4. Intelligent control system:
• Built-in microprocessor control, supporting programming and data logging.
• Touch screen operation interface, easy to set and monitor temperature curve.
• Support remote monitoring and data transmission, convenient to manage and record experimental data.
5. Efficient refrigeration and heating system:
• Adopt efficient compressor refrigeration system to quickly reduce temperature.
• Electric heating element provides fast heating capability to meet high temperature operation needs.
6. Safety protection function:
• Over temperature protection: Automatically stop heating when the temperature exceeds the set value.
• Low liquid level alarm: Alarm when the heat transfer medium level is too low.
• Pressure protection: Prevent system pressure from being too high to ensure safe operation.
7. Compact design:
• Compact design, small footprint, suitable for laboratory benchtop use.
• Easy to move and install, easy to use on different laboratory benches.
8. Easy to maintain:
• Easy to disassemble and clean, convenient for daily maintenance.
• Some models are equipped with self-cleaning function to reduce maintenance workload.
Application areas of refrigeration and heating laboratory circulators
• Chemical synthesis: organic synthesis, catalytic reaction, etc.
•Pharmaceutical R&D: drug synthesis, extraction, purification, etc.
•Material Science: R&D and testing of new materials.
•Biotechnology: enzyme activity research, protein crystallization, etc.
•Food processing: food composition analysis, microbial culture, etc.
Key points for selecting refrigeration and heating laboratory circulators
1. Temperature range:
• Make sure that the operating temperature range of the selected equipment covers your specific needs.
2. Temperature control accuracy:
• Select the appropriate accuracy level according to the experimental requirements for temperature control.
3. Capacity and flow:
• Select the appropriate equipment capacity and fluid flow according to actual needs to ensure that the heat load requirements of the reactor or other equipment are met.
4. Medium compatibility:
• Choose a system suitable for the heat transfer medium you use to ensure long-term stable operation.
5. Control system:
• Choose equipment with an intelligent control system that is easy to set up and monitor, and supports programming and data logging functions.
6. Safety:
• Ensure that the equipment has the necessary safety protection measures to prevent accidents.
7. Maintenance and Care:
• Choose equipment that is easy to maintain and care for, reducing long-term operating costs.
If you have a specific budget range, application scenario, or special requirements, please provide more details and I will provide you with more specific suggestions and recommendations. This will help you better choose a cooling and heating laboratory circulator that suits your laboratory needs.
완벽한 온도 제어 시스템 설계 및 제조를 제공합니다. 표준 모델부터 완벽한 맞춤형 제품까지. 고객 서비스를 전문으로 하며 각 고객이 특정 요구에 맞는 최적의 온도 제어 시스템을 갖출 수 있도록 최선을 다하고 있습니다.
비표준 맞춤형 솔루션을 제공합니다. 단일 냉각 냉각기와 냉각 및 난방 콤보 장치를 모두 사용할 수 있습니다.
이메일: lilia@lneya.com WeChat ID: +8615251628237 WhatsApp: +86 17851209193
- 온도 범위: -120℃ ~ +350℃
- 고정밀, 지능형 온도 제어
- 냉각 용량: 0.5kW ~ 1200kW
- 열 유체의 수명을 연장하는 완전 밀폐형 시스템
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -10 ~ +150°C 시리즈 | -25 ~ +200°C 시리즈 | -25 ~ +300°C 시리즈 | -45 ~ +250°C 시리즈 | -45 ~ +300°C 시리즈 | -60 ~ +250°C 시리즈 | -60 ~ +300°C 시리즈 | -70 ~ +250°C 시리즈 | -80 ~ +250°C 시리즈 | -90 ~ +250°C 시리즈 | -100 ~ +100°C 시리즈 | ||
냉각 용량 | 1.5 ~ 15kW | 1~200kW | 1~200kW | 0.45 ~ 200kW | 0.9 ~ 25kW | 0.25 ~ 60kW | 0.75 ~ 25kW | 0.4 ~ 15kW | 0.3 ~ 80kW | 0.2 ~ 80kW | 0.45 ~ 80kW | ||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
- 온도 범위: -45℃ ~ +250℃
- 에머슨 코플랜드 컴프레서, 신뢰할 수 있는 품질
- 자가 진단 기능, 다중 안전 보호 장치
- 열 유체의 수명을 연장하는 완전 밀폐형 시스템
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -25°C ~ +200°C 시리즈 | -45°C ~ +250°C 시리즈 | |||||||
냉각 용량 | 1 ~ 15kW | 0.25 ~ 15kW | |||||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
- (마이크로 채널/튜브 리액터 전문)
- 온도 범위: -70℃ ~ +300℃
- 고성능 순환 펌프, 보다 안정적인 온도 제어 효과
- 더 많은 산업의 요구를 충족하는 넓은 온도 범위
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C | ||||||
냉각 용량 | 1.1 ~ 7.5kW | 1.5 ~ 5.5kW | 11 ~ 50kW | ||||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |
- 온도 범위: -120℃ ~ +250℃
- 밀폐된 반복 가능한 온도 제어
- 내장형 전기 난방 열유 보조 시스템
- 필요에 따라 냉기 및 열원 열교환 모듈 추가
- 각 장치는 12시간 이상 부하 테스트를 거칩니다.
온도 범위 | -45°C ~ +250°C 시리즈 | -120°C ~ +250°C 시리즈 | 맞춤형 온도 제어 시스템 | RT+10°C ~ +135°C | |||||
난방 용량 | 25 ~ 80kW | 25 ~ 80kW | 사용자 지정 | 25 ~ 300kW | |||||
참고: -150℃ ~ +350℃의 모든 온도 범위와 모든 냉각 용량을 맞춤 설정할 수 있습니다. |