Heater Chiller Combo
Installation and commissioning of heater chiller combo:
The heater chiller combo consists of two systems, two computer PC boards, each controls the corresponding system, and automatically adjusts heating or cooling according to process requirements through heat transfer oil circulation. It consists of pumps, heating tubes, cooling heat exchangers, refrigeration systems, temperature control systems, piping and racks. The heat transfer oil flows between the heat medium pipeline of the unit and the jacket or coil of the reactor, the circulation pump, the heat transfer oil pipeline, the heating device and the cooling device constitute the basic circuit of the heat medium.
First connect the power supply of the heater chiller combo. Before installation, it is necessary to understand the circuit requirements of the all-in-one machine. If conditions permit, try to connect it in parallel with other equipment on the circuit, and it is recommended to set the switch of the high and low temperature all-in-one machine separately. Because this can ensure that the circuit of other equipment or the equipment itself fails without affecting normal use. After the installation is complete, plug in the power plug, and turn on the switch of the main power supply and the drain valve. The switch of the main power supply is self-evident. Basically no one will ignore this switch, but the switch of the drain valve will be ignored by many people without paying attention. The consequence of not opening the drain valve switch is that the heater chiller combo cannot perform water circulation during operation, and a large amount of water will accumulate inside the all-in-one machine, hindering its normal operation, and even causing electric leakage. After ensuring that the switches of the main power supply and the drain valve are both on, adjust the data required for the test. At this time, it should be noted that the input data cannot exceed the standard limited by the machine itself. After the data is debugged, prepare for observation and record when necessary. After the natural shutdown according to the specified time, the power should be turned off in time. Prevent electric leakage and accidents when left unattended.
Customized Solutions For Your Business
Cooling and Heating Systems (SUNDI series)
Temperature Control Range: -120°C to +350°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Automotive Industry, Semiconductor and Electrical Test, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -40 ~ +200°C series | -10 ~ +200°C series | -25 ~ +200°C series | -25 ~ +300°C series | -45 ~ +250°C series | -45 ~ +300°C series | -60 ~ +250°C series | -60 ~ +300°C series | -70 ~ +250°C series | -80 ~ +250°C series | -90 ~ +250°C series | -100 ~ +100°C series | -25 ~ +200°C one machine for two reactors | -40 ~ +200°C one machine for two reactors |
Cooling Capacity | up to 3kW | up to 15kW | up to 200kW | up to 200kW | up to 200kW | up to 25kW | up to 60kW | up to 25kW | up to 15kW | up to 80kW | up to 80kW | up to 80kW | up to 10*2kW | up to 10*2kW |
Cooling and Heating Systems (WTD series)
(Micro channel / tube reactors specialized)
Temperature Control Range: -70°C to +300°C
Specialized design for micro channel (small liquid holding capacity, strong heat exchange capacity, circulation system high pressure drop)
Temperature range | -70°C ~ +300°C | -45°C ~ +250°C | -70°C ~ +200°C |
Cooling Capacity | up to 7.5kW | up to 5.5kW | up to 50kW |
Cooling and Heating Systems (TES series)
Temperature Control Range: -85°C ~ +250°C
Temp Control Accuracy: ± 0.3°C
Temperature range | -45°C ~ +250°C series | -85°C ~ +200°C series | -60°C ~ +200°C series |
Cooling Capacity | up to 25kW | up to 25kW | up to 60kW |
Cooling and Heating Machines (LTS series)
Temperature Control Range: -80°C to +80°C
It is widely used in the semiconductor process to control the temperature of the reaction chamber, the hot sink plate and the non-flammable heat transfer medium.
Temperature range | -20°C ~ +80°C series | -45°C ~ +80°C series | -60°C ~ +80°C series | -80°C ~ +80°C series |
Flow Control | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min | 7 ~ 45 L/min |
Cooling and Heating Circulators
Temperature Control Range: -45°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -25°C ~ +200°C series | -45°C ~ +250°C series |
Cooling Capacity | up to 15kW | up to 15kW |
Heating Circulators
Temperature Control Range: +50°C to +300°C
Note: UC series can control the temperature of heat transfer medium. UST series can not only control the temperature of the heat transfer medium, but also control the temperature of the reaction material.
Temperature range | +50°C ~ +200°C (UC series) | +50°C ~ +300°C (UC series) | +50°C ~ +300°C (UST series) |
Heating Capacity | up to 38kW | up to 200kW | up to 95kW |
TCU Multi-reactors Temperature Control System
Temperature Control Range: -120°C to +250°C
Application: Various Reactors (Microchannels, Glass, Jacketed Reactors, etc.), Distillation or Extraction System, Laboratory, University, Research Institute, Aerospace, Chemical, Pharmaceutical, Petrochemical, Biochemical, Medical, Hospital, R&D Workshop, Aerospace, Biological and Other Industries.
Temperature range | -45°C ~ +250°C series | -120°C ~ +250°C series | Customized Temperature Control System | RT+10°C ~ +135°C |
Heating Capacity | up to 80kW | up to 80kW | Custom | up to 300kW |