Data Center Chilled Water System

ClasificaciónNoticias del sector 47 0

Data Center Chilled Water System

 

Driven by developments in artificial intelligence, edge computing and the Internet of Things, modular data centers have become a critical component of successful operations for many businesses. The increasing reliance on computing makes the limitations of traditional modular data centers even more apparent. These disadvantages include a lack of flexibility, inefficiencies due to scale, and high costs associated with local transaction work.

Demands for more critical power, flexible cooling options and just-in-time IT capacity are also changing. Today, traditional data centers with 60-100kW and 10-12 racks may no longer be sufficient, highlighting the importance and relevance of modular data centers that can meet the dynamic needs of today’s enterprises. Amid these challenges, businesses may consider prefabricated modular solutions (PFM) and chilled water systems as more suitable options.

Use chilled water systems to accommodate high-density computing

Thermal management is an important pillar of successful data center operations. Effective thermal management not only ensures equipment reliability but also addresses issues such as cost control, operational savings and environmental sustainability.

In the past, thermal management in data centers has been dominated by direct expansion (DX) cooling units, also known as computer room air conditioners or CRAC units. These devices remove heat from the air through a vapor compression cycle. However, the market is now looking for alternative solutions that improve operational efficiency and energy efficiency, such as chilled water systems.

Chilled water systems use water instead of air for cooling. These solutions are also based on vapor compression, but often include free cooling capabilities and achieve greater overall efficiency through a wider range of centralized components outside of the white space.

In chilled water systems, refrigerant is stored in refrigeration units with pretested circuits to prevent leaks. Monitoring systems can detect leaks during operation and help prevent refrigerant loss. Chilled water systems can use other refrigerants with less impact on the atmosphere, including hydrofluoroolefins (HFO) and HFO blends.

 

Data Center Chilled Water System

 

Advantages of Chilled Water Systems

Chilled water systems offer several combined benefits, and this solution will become the dominant global cooling technology for data centers for the foreseeable future. These advantages include its inherent large-scale efficiency, the ability to take advantage of lower ambient air temperatures for free cooling, and reduced environmental impact through environmentally friendly refrigerants. These features enhance operational capabilities and align with global sustainability goals, making chilled water systems a strategic choice for future-proof data center operations.

1. Reduce carbon emissions

Chilled water systems can use low global warming potential (GWP) refrigerant types such as HFO to reduce direct emissions. To illustrate the environmental benefits of these refrigerants, let’s look at their impact on two common chillers:

Small and medium-sized data center chillers have traditionally used R410A (GWP1924), and alternatives such as natural refrigerants such as R454B (GWP466), R32 (GWP677) or R290 are now available.

Medium and large data centers have historically used chillers with screw, or centrifugal compressors to cool their equipment, using R134a coolant with a GWP of 1300. Now, they are switching to coolants such as R513A, which has a GWP of 573, or R1234ze, which has a GWP of less than 1, to reduce their environmental impact.

Chilled water systems therefore offer a more efficient alternative to traditional cooling methods and reduce direct emissions without requiring significant investments or changes to existing data center layouts.

Chilled water systems can also reduce indirect emissions by improving energy efficiency, potentially supporting partial power usage effectiveness (pPUE) below 1.1. With growing concerns about global warming and environmental sustainability, some regions are now mandating such thermal solutions.

2. Enhance data center security and flexibility

In addition to sustainability, the design of the system also deserves attention, especially given concerns about the flammability of modern refrigerants. Chilled water systems have the advantage of placing the cooling units outside the data center, mitigating any type of risk associated with the facility’s flammable refrigerants.

Additionally, chilled water systems offer inherent flexibility in outdoor cooling unit placement. Chilled water systems have no fixed configuration requirements and physical limitations and can be adapted to a variety of operational needs.

3. Improve continuity

What’s more, the chilled water system provides a strong continuity measure, utilizing auxiliary cold water storage tanks to enhance thermal reserves during power outages, ensuring uninterrupted cooling to maintain optimal operating conditions. With these multiple benefits, chilled water systems are a reliable and effective solution to meet the ever-changing demands of contemporary data center environments.

Chilled water systems are also available in non-raised floor designs, providing the flexibility to add liquid cooling to existing data centers. This is an emerging requirement for high-density computing needs that is gaining more and more attention over time.

4. The preferred solution for high-density support

Due to its reliability, scalability and enhanced thermal capacity, chilled water is used in a wide range of applications including telecommunications, government, energy/utilities, security, manufacturing and science. Chilled water is becoming the cooling method of choice for large-scale and high-performance computing applications.

 

Model One: 15 ~ 150kW

ModeloZLFQ-15ZLFQ-25ZLFQ-50ZLFQ-75ZLFQ-100ZLFQ-150
Rango de temperatura +5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃+5℃~35℃
Agua de refrigeración5℃~30℃ Adopta válvula reguladora Siemens/Honeywell para controlar el flujo de agua de refrigeración.
Precisión del control de temperatura±0.2℃±0.5℃±0.5℃±0.5℃±0.5℃±0.5℃
control de flujo10~25L/min25~50L/min40~110L/min70~150L/min150~250L/min200~400L/min
El control de caudal se ajusta mediante un convertidor de frecuencia, la precisión es de ±0,3 L/min.
Capacidad de refrigeración (MAX)15 kW25 kW50 kW75 kW100 kW150 kW
Volumen de almacenamiento15L30L60L100L150L200L
SalmueraAgua, aceite de silicona, líquido fluorado, solución acuosa de etilenglicol, etc.
controladorPLC, fuzzy PID control algorithm, with cascade control algorithm
temperature controlHeat transfer medium outlet temperature control mode, with cascade control algorithm
letter of agreementInterfaz Ethernet Protocolo TCP/IP
Interfaz RS485 protocolo modbus RTU
Device Internal Temperature FeedbackEquipment heat transfer medium outlet temperature, medium inlet temperature, cooling water temperature
tank levelImport and export pressure sensor detection, cooling water pressure detection
Canalización mediaSUS304SUS304SUS304SUS304SUS304SUS304
Heat ExchangerPlate heat exchanger, special attention: need to use clean factory water
operation panelWuxi Guanya personalizado de 7 pulgadas de pantalla táctil en color, visualización de la curva de temperatura\EXCEL exportación de datos
SeguridadWith self-diagnosis function; phase sequence and phase failure protector; pressure protection, overload relay, thermal protection device and other safety protection functions.
Tamaño de la interfaz de entrada y salidaG3/4G1G1DN32DN40DN50
Interfaz de agua de refrigeraciónG3/4G1DN40DN50DN50DN65
cooling methodWater-cooled, the factory water temperature is lower than the minimum temperature provided by the equipment by more than 3°C, and the water temperature fluctuation is ≤3°C
Caudal de agua de refrigeración 7~20℃2,5 m³/h4 m³/h8m³/h13 m³/h17 m³/h25 m³/h
power supply
380V 50HZ 1kW1,5 kW3kW4kW5kW6kW
conchaChapa laminada en frío pulverizada RAL7035

 

Model Two: 200 ~ 500kW

ModeloZLFQ-200ZLFQ-250ZLFQ-300ZLFQ-400ZLFQ-500
Rango de temperatura +5℃~35℃
Precisión de la temperatura±0.5℃
Control del caudal15~30m³/h20~35m³/h25~40m³/h30~60m³/h40~70m³/h
Flow control is adjusted by frequency converter
Capacidad de refrigeración(MAX) 200 kW250 kW300 kW400 kW500 kW
Volumen de almacenamiento250L300L600L1000L1200L
Sistema de refrigeraciónThe plant service water exchanges heat with the brine, and the brine provides cooling capacity for the heating equipment
MedioAgua, aceite de silicona, líquido fluorado, solución acuosa de etilenglicol, etc.
controladorPLC, fuzzy PID control algorithm, with cascade control algorithm
temperature controlHeat transfer medium outlet temperature control mode式
letter of agreementInterfaz Ethernet Protocolo TCP/IP
Interfaz RS485 protocolo modbus RTU
Device Internal Temperature FeedbackEquipment heat transfer medium outlet temperature, medium inlet temperature, cooling water temperature
tank levelPressure sensor real-time monitoring
Canalización mediaSUS304
System pressureUsing the pressure sensor to detect and display on the touch screen
Heat ExchangerPlate heat exchanger, special attention: need to use clean factory water
operation panelWuxi Guanya personalizado de 7 pulgadas de pantalla táctil en color, visualización de la curva de temperatura\EXCEL exportación de datos
SeguridadWith self-diagnosis function; phase sequence and phase failure protector; pressure protection, overload relay, thermal protection device and other safety protection functions.
Tamaño de la interfaz de entrada y salidaDN65DN65DN65DN80DN80
Interfaz de agua de refrigeraciónDN80DN80DN100DN100DN125
cooling methodWater-cooled, the factory water temperature is lower than the minimum temperature provided by the equipment by more than 3°C, and the water temperature fluctuation is ≤3°C
Caudal de agua de refrigeración 7~20℃34 m³/h43 m³/h51 m³/h69 m³/h86 m³/h
Alimentación 380V 50HZ7kW7kW8kW9kW13kW
conchaChapa laminada en frío pulverizada RAL7035

 

unidad de distribución de frío

La información sobre derechos de autor pertenece a lneya-online.com, por favor contacte por correo electrónico para más detalles: lilia@lneya.com

O escanee el código QR de WhatsApp o WeChat que aparece a continuación para ponerse en contacto con nosotros. 

WhatsAPP WeChat

escanear

Anterior: Siguiente:
Solicitar presupuesto
Llame a
Buzón
Nombre
Empresa
Rellene sus requisitos de producto
展开更多
Obtener presupuesto gratuito

cargando...

购物车

X

我的足迹

X
palabras clave:Alegría embotellada enfriador de agua