Search

medical chiller

Medical Chillers

Common Cooling Applications

medical equipment chiller

Medical Equipment Temperature Control

  • ‌Large Medical Equipment Cooling‌: Provides continuous cooling for high-power instruments such as MRI, CT scanners, and PET devices, ensuring accurate diagnosis and treatment and extending device life.
  • Laser Medical Equipment Support‌: Stabilizes laser cavity temperature during laser surgeries (such as corrective ophthalmology and tumor ablation) to ensure beam quality and precision. In aesthetic medicine (such as laser hair removal and tattoo removal), it is used to reduce the temperature of the treatment site and minimize thermal damage to tissue.

Medical Environment & Sample Management

  • Laboratory and Operating Room Temperature Control‌: Maintains stable temperature and humidity in laboratory environments (such as cell culture and biochemical reactions) and operating rooms to ensure experimental reproducibility and surgical safety.
  • ‌Biological Sample Preservation‌: Provides a low-temperature storage environment for sensitive medical samples such as blood and tissue to prevent deterioration.

Direct Clinical Treatment Assistance

  • ‌Patient Temperature Control‌: Controls patient temperature during surgery or specific treatments (such as hyperpyrexia management) through cooling circulation systems.
  • ‌Local Therapeutic Applications: Targeted cooling during intravenous therapy or skin surgery reduces the risk of inflammatory reactions.

Related Products

Low Temperature Chillers (Custom design)

The low temperature chiller uses ultra-low temperature cooling technology and international brand accessories to achieve rapid cooling from high temperature to meet the temperature control needs of medical and biotechnology processes.

ModelLC seriesLJ seriesLN seriesLD seriesCDLJ seriesSLJ series
Temperature range -25 ~ -5 °C -45 ~ -10 °C -60 ~ -10 °C -80 ~ -30 °C-110 ~ -50 °C -150 ~ -110 °C
Cooling capacity12 … 360 kW6 … 180 kW6 … 180 kW4 … 180 kW2 … 120 kW2.5 … 11 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Recirculating Chillers / Refrigerated Circulators (Custom design)

The low temperature refrigerated circulator adopts a fully closed circulation cooling system to save energy and reduce consumption. It also supports customized design and can be customized according to your process project requirements.

ModelLX seriesLT-45 seriesLT-60 seriesLT-80 seriesLT-120 series
Temperature range -25 ~ +30 °C -45 ~ +30 °C -60 ~ -20 °C -80 ~ -20 °C -120 ~ -70 °C
Cooling capacity0.8 … 30 kW0.75 … 12 kW0.4 … 6 kW0.2k … 6 kW0.3 … 5 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure20 … 250 L/min20 … 50 L/min20 … 50 L/min20 … 50 L/min20 … 35 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Room Temperature Chillers & Mini Chiller (Custom design)

Our small water chillers have a compact design and take up little space, so they can be placed on a desktop for use.

ModelFL-800FL series
Temperature range -18 ~ +30 °C +5 ~ +35 °C
Cooling capacity0.35 ~ 0.9 kW1.8 … 50 kW
Temperature stability±0.5 ℃±0.5 ℃
Pump flow pressure25 … 250 L/min10 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Chiller / Heater Combo Units (Custom design)

We offer cooling and heating combination units that integrate refrigeration, heating and thermostatic control to achieve dynamic temperature control functions.

ModelSUNDI-1SUNDI-2SUNDI-23SUNDI-4SUNDI-43SUNDI-6SUNDI-63SUNDI-7SUNDI-8SUNDI-9SUNDI-10
Temperature range -10 ~ +150 °C-25 ~ +200 °C -25 ~ +300 °C-45 ~ +250 °C -45 ~ +300 °C -60 ~ +250 °C -60 ~ +300 °C -70 ~ +250 °C -80 ~ +250 °C-90 ~ +250 °C -100 ~ +100 °C
Cooling capacity1.5 … 15 kW1 … 200 kW1 … 200 kW0.45 … 200 kW0.9 … 25 kW0.25 … 60 kW0.75 … 25 kW0.4 … 15 kW0.3 … 80 kW0.2 … 80 kW0.45 … 80 kW
Heating capacity2.5 … 15 kW2.5 … 200 kW2.5 … 200 kW2.5 … 200 kW5.5 … 25 kW2.5 … 60 kW5.5 … 25 kW2.5 … 15 kW3 … 80 kW3 … 80 kW 3.5 … 80 kW
Pump flow pressure20 … 75 L/min20 … 600 L/min20 … 600 L/min20 … 600 L/min35 … 150 L/min20 … 250 L/min35 … 150 L/min20 … 110 L/min20 … 400 L/min20 … 400 L/min35 … 400 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Recirculating Heater Chiller / Cooling Heating Circulator (Custom design)

Our refrigeration and heating circulators can achieve dynamic temperature control between -45°C and +250°C, using a closed loop control system to save energy.

ModelHRHRT
Temperature range  -25 ~ +200 °C -45 ~ +250 °C
Cooling capacity1 … 15 kW0.25 … 15 kW
Heating capacity2.5 … 15 kW2.5 … 15 kW
Pump flow pressure20 … 110 L/min20 … 110 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Heating Systems / Circulation Heaters (Custom design)

The heating circulator can achieve ultra-high temperature control of 300℃, adopts closed circulation heating, and the system is equipped with an expansion vessel.

Model UC-1UC-2UST
Temperature range+50 ~ +170 °C +50 ~ +300 °C +50 ~ +300 °C
Temperature accuracy±0.5 ℃±0.5 ℃±0.5 ℃
Heating capacity5.5 … 15 kW3.5 … 130 kW3.5 … 95 kW
Pump flow pressure35 … 50 L/min35 … 400 L/min35 … 400 L/min

Customer Cases

Product Advantages

  • Providing a stable low-temperature environment: Many precision instruments in medical equipment require a specific low-temperature environment to function properly. For example, cryotherapy equipment and cell culture equipment require a stable low-temperature environment. Chillers can provide a continuous, stable low temperature, creating an ideal operating environment for these medical devices, thereby improving operational efficiency and accuracy.
  • Protecting medical equipment from overheating: Medical equipment generates significant heat during prolonged operation. Chillers, by circulating cooling water, effectively dissipate this heat, preventing overheating and thus extending the lifespan of the equipment.
  • Improving the quality and safety of medical procedures: Medical procedures such as magnetic resonance imaging (MRI) and CT scans require high-precision temperature control to ensure image quality and diagnostic accuracy. Chillers can provide stable temperature control, reducing the impact of temperature fluctuations on device performance and image quality, thereby improving the quality and safety of medical procedures.
  • Reducing electromagnetic radiation levels: Some medical equipment, such as MRI machines, generates electromagnetic radiation during operation. While this radiation is generally harmless to the human body, excessive levels can still pose a threat to patients. Chillers help reduce electromagnetic radiation levels by lowering the internal temperature of the equipment.

Why Choose Us?

About LNEYA®

About Us