Search

chemical pharma chiller

Chemical Pharmaceutical Chillers

Common Cooling Applications

pharmaceutical chillers

Chemical Reaction Control

Provides cooling water for processes such as polymerization, distillation, and rectification to prevent side reactions or equipment damage caused by high temperatures. For example, in the production of polyethylene and epoxy resins, chillers maintain process temperatures by cooling the reactor medium.

Fermentation & Biochemical Engineering

Used to cool fermentation tanks, culture media, and other equipment to ensure stable temperatures within the fermentation range (for example, maintaining a constant temperature in the production of antibiotics and enzyme preparations).

Equipment Cooling & Crystallization

In the production of chemical products such as urea and hydrochloric acid, cooling the solution to the crystallization point promotes crystal precipitation, improving product purity and yield.

Solvent Recovery & Distillation

Cooling distillation overhead vapor promotes condensation and reflux, improving solvent recovery and purity.

Waste Gas Treatment

Used to cool pollutants (such as hydrogen sulfide) in flue gas, facilitating subsequent treatment and reducing the environmental impact of emissions.

Related Products

Low Temperature Chillers (Custom design)

The low temperature chiller uses ultra-low temperature cooling technology and international brand accessories to achieve rapid cooling from high temperature to meet the temperature control needs of medical and biotechnology processes.

ModelLC seriesLJ seriesLN seriesLD seriesCDLJ seriesSLJ series
Temperature range -25 ~ -5 °C -45 ~ -10 °C -60 ~ -10 °C -80 ~ -30 °C-110 ~ -50 °C -150 ~ -110 °C
Cooling capacity12 … 360 kW6 … 180 kW6 … 180 kW4 … 180 kW2 … 120 kW2.5 … 11 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h6.6 … 25 m³/h
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Recirculating Chillers / Refrigerated Circulators (Custom design)

The low temperature refrigerated circulator adopts a fully closed circulation cooling system to save energy and reduce consumption. It also supports customized design and can be customized according to your process project requirements.

ModelLX seriesLT-45 seriesLT-60 seriesLT-80 seriesLT-120 series
Temperature range -25 ~ +30 °C -45 ~ +30 °C -60 ~ -20 °C -80 ~ -20 °C -120 ~ -70 °C
Cooling capacity0.8 … 30 kW0.75 … 12 kW0.4 … 6 kW0.2k … 6 kW0.3 … 5 kW
Temperature stability±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃±0.5 ℃
Pump flow pressure20 … 250 L/min20 … 50 L/min20 … 50 L/min20 … 50 L/min20 … 35 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Room Temperature Chillers & Mini Chiller (Custom design)

Our small water chillers have a compact design and take up little space, so they can be placed on a desktop for use.

ModelFL-800FL series
Temperature range -18 ~ +30 °C +5 ~ +35 °C
Cooling capacity0.35 ~ 0.9 kW1.8 … 50 kW
Temperature stability±0.5 ℃±0.5 ℃
Pump flow pressure25 … 250 L/min10 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Chiller / Heater Combo Units (Custom design)

We offer cooling and heating combination units that integrate refrigeration, heating and thermostatic control to achieve dynamic temperature control functions.

ModelSUNDI-1SUNDI-2SUNDI-23SUNDI-4SUNDI-43SUNDI-6SUNDI-63SUNDI-7SUNDI-8SUNDI-9SUNDI-10
Temperature range -10 ~ +150 °C-25 ~ +200 °C -25 ~ +300 °C-45 ~ +250 °C -45 ~ +300 °C -60 ~ +250 °C -60 ~ +300 °C -70 ~ +250 °C -80 ~ +250 °C-90 ~ +250 °C -100 ~ +100 °C
Cooling capacity1.5 … 15 kW1 … 200 kW1 … 200 kW0.45 … 200 kW0.9 … 25 kW0.25 … 60 kW0.75 … 25 kW0.4 … 15 kW0.3 … 80 kW0.2 … 80 kW0.45 … 80 kW
Heating capacity2.5 … 15 kW2.5 … 200 kW2.5 … 200 kW2.5 … 200 kW5.5 … 25 kW2.5 … 60 kW5.5 … 25 kW2.5 … 15 kW3 … 80 kW3 … 80 kW 3.5 … 80 kW
Pump flow pressure20 … 75 L/min20 … 600 L/min20 … 600 L/min20 … 600 L/min35 … 150 L/min20 … 250 L/min35 … 150 L/min20 … 110 L/min20 … 400 L/min20 … 400 L/min35 … 400 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Recirculating Heater Chiller / Cooling Heating Circulator (Custom design)

Our refrigeration and heating circulators can achieve dynamic temperature control between -45°C and +250°C, using a closed loop control system to save energy.

ModelHRHRT
Temperature range  -25 ~ +200 °C -45 ~ +250 °C
Cooling capacity1 … 15 kW0.25 … 15 kW
Heating capacity2.5 … 15 kW2.5 … 15 kW
Pump flow pressure20 … 110 L/min20 … 110 L/min
Note: Any temperature range from -150℃ ~ +350℃ and any cooling capacity can be customized

Heating Systems / Circulation Heaters (Custom design)

The heating circulator can achieve ultra-high temperature control of 300℃, adopts closed circulation heating, and the system is equipped with an expansion vessel.

Model UC-1UC-2UST
Temperature range+50 ~ +170 °C +50 ~ +300 °C +50 ~ +300 °C
Temperature accuracy±0.5 ℃±0.5 ℃±0.5 ℃
Heating capacity5.5 … 15 kW3.5 … 130 kW3.5 … 95 kW
Pump flow pressure35 … 50 L/min35 … 400 L/min35 … 400 L/min

Customer Cases

Product Advantages

  • Precise Temperature Control: Chillers provide a stable supply of low-temperature cooling water, ensuring chemical reactions proceed at the set temperature, avoiding product quality degradation or safety hazards caused by temperature fluctuations. For example, temperature-sensitive pharmaceutical ingredients in the pharmaceutical manufacturing process must be strictly controlled within a specific range. Chillers can achieve precise temperature control within ±0.5°C.
  • Equipment Protection: Chillers cool industrial equipment, preventing overheating and damage, thereby extending its service life. Chillers circulate cooling water to lower operating temperatures, reducing maintenance costs.
  • Energy Efficiency: Modern chillers utilize high-efficiency compressors (such as screw and magnetic levitation technologies) and plate heat exchangers, resulting in cooling efficiency improvements of over 30% and energy reductions of 20% compared to traditional equipment. Magnetic levitation models utilize a refrigerated oil-free system, resulting in quieter operation and reduced oil system power consumption.
  • Adaptable to diverse process requirements: Chemical production encompasses applications such as reaction cooling, solvent recovery, and waste gas treatment. Chillers adjust their cooling capacity to meet diverse process requirements. For example, they cool the reaction medium in polyester production and maintain a constant temperature in fermentation tanks during fermentation.

Why Choose Us?

About LNEYA®

About Us